- Protection function: ABB Rigi crowbar drive PCB identified by material number 3BHE024747R0101 and designation GD C801 A101.
- Variant control: The A101 suffix identifies the required PCB variant and remains part of the complete selection identity.
- Service context: Work on the crowbar protection path requires the site's approved isolation, discharge, and acceptance procedures.
3BHE024747R0101 GD C801 A101 is the complete purchasing identity for this ABB Rigi crowbar drive PCB, combining the material number with the GD C801 A101 designation.
Because the board is associated with the drive protection path, replacement planning must address both exact variant matching and the site's stored-energy controls rather than treating it as a generic logic board.
Before release for installation, compare the label, connector orientation, mounting points, host-drive record, and physical condition; stop when the A101 variant or interface evidence does not agree.
Apter Power provides document review, quotation, and procurement support for the ABB 3BHE024747R0101 GD C801 A101 Rigi Crowbar Drive PCB.
ABB 3BHE024747R0101 GD C801 A101 Rigi Crowbar Drive PCB Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Material number: Confirm 3BHE024747R0101 on the installed PCB and purchase record.
- PCB designation: Retain GD C801 A101 in full, including the A101 suffix.
- Selection rule: Do not approve a replacement from the shortened GD C801 name alone.
- System role: Treat the board as part of the Rigi crowbar drive protection path.
- Energy control: Follow the approved drive isolation and stored-energy discharge procedure before access.
- Physical interfaces: Verify connector orientation, mounting points, and the host-drive record before fitting.
- Release condition: Use the approved protection-path checks before returning the drive to service.
- Fault context: Retain the drive fault and alarm history before the existing PCB is removed.
- Pre-work record: Capture the full label, connector map, board orientation, and visible condition.
- Receiving decision: Quarantine a board with an identity mismatch, damaged interface, or unacceptable physical condition.
- Acceptance: Record the approved post-exchange protection checks and return-to-service decision.
- Crowbar maintenance: Exact-variant replacement within an ABB Rigi drive protection assembly.
- Outage preparation: Identity, interface, fault-history, and stored-energy planning before exchange.
- Receiving control: A101 variant and physical-condition verification before stock release.
- Lifecycle spares: Controlled inventory under the complete material-number and PCB-designation identity.