ACS510-01-012A-4

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS510-01-012A-4 is a 5.5 kW, 11.9 A, 380-480 V IP21 ACS510 wall-mounted drive in frame R1.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS510-01-012A-4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS510-01-012A-4

  • Manufacturer:
    ABB
  • Part Number:
    ACS510-01-012A-4
  • Product Family:
    ABB Drives
  • Product Type:
    ACS510 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3ABD00015746-D
  • Input Voltage:
    380 ... 480 V AC
  • Input Frequency:
    47.5 ... 63 Hz
  • Number of Phases:
    3-phase
  • Normal Output Current:
    11.9 A
  • Normal Output Power:
    5.5 kW
  • Apparent Power Output:
    8.3 kV·A
  • Frame Size:
    R1
  • Degree of Protection:
    IP21
  • Enclosure Type:
    NEMA Type 1
  • Mounting:
    Wall-mounted
  • Efficiency Level:
    IE2
  • Standby Loss:
    12 W
  • Temperature Rating:
    40 °C
  • Built-in Communication:
    Modbus
  • Weight:
    6.1 kg
  • Estimated shipping dimensions:
    22.5 x 36.5 x 46.5 cm
  • Tariff Code:
    85044099
  • Country of origin:
    China
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Pump Duty Cabinet Layout Signal Review

Features:

  • 5.5 kW normal-use rating with 11.9 A output
  • R1 IP21 wall-mounted mechanical format
  • Standard assistant panel and integrated Modbus connectivity
ACS510-01-012A-4 provides the 11.9 A step within the compact R1 group for 5.5 kW applications.

The control platform can regulate common variable-torque processes while exchanging commands and feedback through terminal signals or a documented Modbus connection.

Selection should be completed with the motor schedule, process reference, feeder study, EMC and cable plan, panel cooling, stopping duty, interlock logic, and commissioning records available.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS510-01-012A-4 ACS510 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS510-01-012A-4 ACS510 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS510-01-012A-4
  • ConditionNew Original ready stock
  • Product FamilyABB ACS510 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Flow-control application review

  • Motor match: Verify current and service factor against the actual pump motor nameplate.
  • Minimum speed: Set process limits that preserve pump and motor operating requirements.
  • Dry-run logic: Define the approved permissives and shutdown response outside the drive.
  • Restart: Document whether automatic restart is permitted after power or process recovery.

R1 electrical and thermal planning

  • Protection: Coordinate the documented fuse basis with fault level and local electrical rules.
  • Airflow: Keep the cooling path clear and prevent recirculation inside the enclosure.
  • Separation: Route power, motor, and control cables in their specified zones.
  • Access: Reserve service space for terminals, panel operation, and fan inspection.

Reference and feedback integrity

  • Analog input: Confirm signal type, scaling, common, shield, and failure response.
  • Relay outputs: Assign status and fault indications to the approved plant logic.
  • Serial data: Freeze Modbus addressing, polling, timeout, and control ownership.
  • Acceptance: Test reference tracking, limits, interlocks, and loss-of-signal behavior.
Description
ACS510-01-012A-4 combines a 5.5 kW normal-use rating with 11.9 A output in ABB's R1 ACS510 enclosure for three-phase 380-480 V systems.

ACS510-01-012A-4 supports variable-speed control of pumps, fans, and conveyors through local operation, hardwired I/O, and the built-in Modbus interface, with coated electronics and the standard ACS510 assistant panel.

ACS510-01-012A-4 requires confirmation of the motor current, process flow or pressure logic, input protection, cable and EMC arrangement, ventilation, analog-signal scaling, stop strategy, and accepted parameter backup before handover.
Alternative Names
ACS510 01 012A 4 ACS51001012A4 3ABD00015746-D ABB ACS510-01-012A-4 ABB 3ABD00015746-D ACS510 5.5 kW drive 11.9 A R1 wall-mounted drive ABB general purpose drive 5.5 kW
Technical notes
For ACS510-01-012A-4, confirm that the feeder can support the documented 16 A IEC fuse basis and that the selected motor remains within the 11.9 A normal-use rating. Plan R1 airflow, PE and shield termination, analog-reference scaling, Modbus ownership, and any resistor required by the internal brake chopper before releasing the panel design.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What must be confirmed before ACS510-01-012A-4 controls a pump?
Check the motor current against the 11.9 A rating, then review the pump curve, minimum safe speed, flow or pressure reference, acceleration, dry-run protection, valve sequence, and restart policy. This confirms that the 5.5 kW drive fits both the motor and hydraulic operating limits.
How should the 16 A feeder basis for ACS510-01-012A-4 be applied?
ACS510-01-012A-4 has an official 16 A IEC fuse basis despite sharing frame R1 with a lower-current configuration. Coordinate that value with site fault current, isolation, conductor installation, voltage drop, PE sizing, terminal range, and local rules instead of copying the smaller feeder design.
Why can a pressure loop hunt after ACS510-01-012A-4 commissioning?
For ACS510-01-012A-4, compare the 11.9 A motor behavior with transmitter scaling, damping, PID direction and gains, pump hydraulics, minimum speed, ramp settings, signal shielding, and sensor location. This separates control-loop instability from a drive or motor current limitation.
Can an R1 parameter backup be loaded directly into ACS510-01-012A-4?
Only after verifying that the backup preserves the 5.5 kW motor data, 11.9 A limits, selected macro, I/O mapping, Modbus settings, ramps, protection, and braking behavior. Keep a rollback copy and perform controlled tests because identical frame size does not prove identical application configuration.
What should be checked when ACS510-01-012A-4 will not start a pump?
Confirm local or remote ownership, run and enable commands, pump permissives, dry-run and valve interlocks, reference availability, fault history, stop mode, motor wiring, and any Modbus control word. The 11.9 A rating should then be monitored during the controlled start attempt.
What information prevents an ACS510-01-012A-4 quotation from being confused with another R1 rating?
Specify ACS510-01-012A-4, Product ID 3ABD00015746-D, the 5.5 kW and 11.9 A duty, 16 A fuse basis, motor and pump data, control scope, quantity, destination, inspection requirements, and requested date. The Product ID and duty point distinguish this configuration during procurement.

Product Browsing History