Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB records, R7 logistics planning, and high-current integration checks.

ACS580-01-169A-4 3AUA0000080505

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS580-01-169A-4 3AUA0000080505 is a 90 kW, 169 A ACS580-01 IP21 wall-mounted drive using the R7 frame.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS580-01-169A-4 3AUA0000080505
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS580-01-169A-4 3AUA0000080505

  • Manufacturer:
    ABB
  • Part Number:
    ACS580-01-169A-4 3AUA0000080505
  • Product Family:
    ABB Drives
  • Product Type:
    ACS580 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000080505
  • EAN:
    6438177305613
  • Nominal Motor Power:
    90 kW
  • Normal Output Current:
    169 A
  • Light-Duty Rating:
    161 A / 90 kW
  • Heavy-Duty Rating:
    145 A / 75 kW
  • Maximum Output Current:
    247 A
  • Frame Size:
    R7
  • Input:
    3-phase, 380–480 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21
  • Mounting:
    Wall-mounted
  • Standard Fieldbus:
    Modbus RTU
  • Control I/O:
    2 AI, 2 AO, 6 DI, 3 DO
  • Weight:
    54 kg
  • Estimated shipping dimensions:
    99.2x59.8x40cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Project Scope Installation Maintenance Plan

Features:

  • 90 kW normal-use rating with 169 A output
  • R7 IP21 wall-mounted drive construction
  • 161 A light-duty and 145 A heavy-duty operating points
ACS580-01-169A-4 3AUA0000080505 is the R7 configuration for 90 kW motor applications on 380–480 V supplies.

The drive’s control and communication resources can integrate a high-current motor feeder with plant references, permissives, feedback, safety functions, and fault reporting.

Successful deployment depends on early agreement about logistics, lifting and support, cable and protection engineering, ventilation, load and braking duty, network ownership, safe commissioning, spares, and maintenance access.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-169A-4 3AUA0000080505 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-169A-4 3AUA0000080505 ACS580 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS580-01-169A-4 3AUA0000080505
  • ConditionNew Original ready stock
  • Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

R7 engineering deliverables

  • Logistics: Define transport dimensions, route, unloading, lifting equipment, and protected storage.
  • Mechanical: Approve mounting support, clearances, cable spaces, and service access.
  • Electrical: Complete protection, isolation, conductor, earthing, and motor studies.
  • Controls: Freeze the signal list, network ownership, safety logic, and commissioning plan.

High-current R7 preparation

  • Lifting: Follow the R7 hardware instructions and approved site lifting plan.
  • Power cables: Control lug selection, crimping, bend radius, support, torque, and phase spacing.
  • Airflow: Provide the required cool-air path without recirculation or obstruction.
  • Inspection: Use witnessed checks for mounting, terminals, PE, shields, control wiring, and options.

Operational readiness

  • Baseline: Archive parameters, motor identification, firmware, option codes, and acceptance readings.
  • Inspection access: Keep fans, filters, terminals, panel, and communication modules serviceable.
  • Fault capture: Preserve operating values and process context before resetting recurrent trips.
  • Contingency: Document isolation, recovery, spare scope, parameter restoration, and post-repair testing.
Description
ACS580-01-169A-4 3AUA0000080505 is the 90 kW, 169 A normal-use configuration at the R7 level of ABB’s 400 V ACS580-01 wall-mounted drive family, identified by Product ID 3AUA0000080505.

ACS580-01-169A-4 3AUA0000080505 serves higher-power general industrial motor duties while bringing process commands, drive I/O, serial communication, local operation, and Safe Torque Off into the engineered control architecture.

ACS580-01-169A-4 3AUA0000080505 requires project-level coordination of transport and lifting, R7 mounting and airflow, high-current protection and terminations, motor and braking calculations, earthing and EMC, fieldbus ownership, safety validation, commissioning, and planned maintenance.
Alternative Names
ACS580 01 169A 4 ACS58001169A4 3AUA0000080505 ABB ACS580-01-169A-4 ABB ACS580-01-169A-4 3AUA0000080505 ACS580 90 kW wall-mounted drive ACS580-01-169A-4 ACS580-01-169A-4 R7 drive ACS580-01-169A-4 169 A drive
Technical notes
Before shipping ACS580-01-169A-4 3AUA0000080505 to site, confirm the transport route, unloading method, lifting equipment, R7 mounting support, and protected storage plan. The 90 kW, 169 A installation also requires the published 250 A IEC fuse basis, high-current conductor and cable-entry design, airflow, braking duty, protective earthing, Safe Torque Off wiring, and site acceptance controls.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What logistics checks are required before shipping ACS580-01-169A-4 3AUA0000080505 to site?
Confirm package dimensions and mass, access route, unloading point, lifting equipment, storage environment, final mounting location, responsible personnel, inspection timing, and protection from impact, moisture, and contamination.
How should the protection study be completed for ACS580-01-169A-4 3AUA0000080505?
Use the available fault current, transformer and feeder data, ABB fuse guidance, isolation equipment, conductor thermal limits, discrimination requirements, PE design, cable installation, and applicable electrical rules.
What must be considered when braking a high-inertia load with ACS580-01-169A-4 3AUA0000080505?
Calculate regenerative energy, peak power, stopping time, repetition, motor speed range, process overhauling torque, DC-link limits, chopper and resistor scope, thermal protection, and the required safe stopping method.
Why can ACS580-01-169A-4 3AUA0000080505 lose communication under heavy load?
Separate process and network symptoms, then inspect supply dips, control power, grounding, shield routing, termination, adapter diagnostics, network errors, timeout settings, cable condition, and event timestamps.
Can ACS580-01-169A-4 3AUA0000080505 be installed before the motor cable is finalized?
The drive can be mechanically positioned, but final cable construction, length, routing, lugs, bend radius, support, PE and shield termination, EMC implications, and terminal access must be approved before power wiring.
Which records should accompany final acceptance of ACS580-01-169A-4 3AUA0000080505?
Include nameplate and option evidence, approved drawings, protection settings, torque records, insulation and PE tests, motor data, parameters, network and STO tests, loaded readings, fault history, backups, and maintenance instructions.