Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB documentation, duty review, and installation planning.

ACS880-01-087A-3 3AUA0000108023

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS880-01-087A-3 3AUA0000108023 is a 45 kW, 87 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R5.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-087A-3 3AUA0000108023
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-087A-3 3AUA0000108023

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-087A-3 3AUA0000108023
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000108023
  • Nominal Motor Power:
    45 kW
  • Normal Output Current:
    87 A
  • Light-Duty Rating:
    83 A / 45 kW
  • Heavy-Duty Rating:
    72 A / 37 kW
  • Maximum Output Current:
    122 A
  • Frame Size:
    R5
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    60 kVA
  • Power Consumption:
    1129 W
  • Sound Pressure:
    64 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    22.8 kg
  • Estimated shipping dimensions:
    89.6x32.9x29.3cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Motor Matching Installation Startup

Features:

  • 45 kW and 87 A normal-use rating at 400 V
  • R5 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-087A-3 3AUA0000108023 is the 45 kW, 87 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-087A-3 3AUA0000108023 uses the R5 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-087A-3 3AUA0000108023 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-087A-3 3AUA0000108023 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-087A-3 3AUA0000108023 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-087A-3 3AUA0000108023
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

45 kW application review

  • Nameplate current: Check actual motor current against the 87 A normal-use and 72 A heavy-duty ratings.
  • Load duty: Document torque characteristic, overload duration, starting demand, inertia, ramps, and braking behavior.
  • Motor system: Confirm motor insulation, cable length, switching conditions, speed range, and required filtering.
  • Derating: Apply the official altitude, temperature, enclosure, and switching-frequency instructions where relevant.

R5 mounting and electrical checks

  • Mounting: Use the approved R5 orientation, fasteners, clearances, and service-access arrangement.
  • Protection: Coordinate isolation, fuses, conductors, prospective fault current, and local electrical requirements.
  • Earthing: Complete PE, cable-shield, EMC, and supply-system checks before power-up.
  • Control wiring: Separate power and control routes and verify I/O, Safe Torque Off, and option-module connections.

R5 commissioning sequence

  • Motor data: Enter and verify the complete nameplate values before the approved identification routine.
  • Direction: Prove rotation with the process uncoupled or otherwise placed in a safe test condition.
  • Interlocks: Test enable, stop, Safe Torque Off, process permissives, references, and network-loss behavior.
  • Records: Archive the accepted parameters, firmware, option codes, readings, fault history, and recovery plan.
Description
ACS880-01-087A-3 3AUA0000108023 delivers a 45 kW, 87 A normal-use rating through the ACS880-01 R5 wall-mounted platform, specified for 380–415 V three-phase input and IP21 enclosure protection.

ACS880-01-087A-3 3AUA0000108023 integrates ABB Direct Torque Control with the drive control unit and configurable I/O, allowing motor references, process feedback, interlocks, Safe Torque Off, and approved communication options to be engineered as one control package.

ACS880-01-087A-3 3AUA0000108023 needs the 83 A light-duty and 72 A heavy-duty ratings, R5 mounting and cable space, feeder protection, enclosure airflow, braking calculation, motor compatibility, communication ownership, safety validation, and service access agreed before purchase.
Alternative Names
ACS880 01 087A 3 ACS88001087A3 3AUA0000108023 ABB ACS880-01-087A-3 ABB ACS880-01-087A-3 3AUA0000108023 ACS880 45 kW R5 wall mounted drive ACS880-01-087A-3 87 A industrial drive
Technical notes
Treat ACS880-01-087A-3 3AUA0000108023 as an R5 installation requiring advance cable-entry, airflow, and service-clearance planning. Confirm the 87 A normal-use and 72 A heavy-duty limits, 380–415 V feeder and protection study, motor cable and PE arrangement, braking duty, Safe Torque Off circuit, communication options, motor identification, and acceptance test plan.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which cable-entry and maintenance-space decisions should be frozen before the R5 drive ACS880-01-087A-3 3AUA0000108023 reaches site?
Approve the mounting orientation, clearances, power and control cable routes, conductor bending, terminal access, airflow path, option access, and removal space. The final arrangement must follow the ABB R5 installation instructions.
How do the 87 A normal-use, 83 A light-duty, and 72 A heavy-duty points change selection of ACS880-01-087A-3 3AUA0000108023?
Match the actual torque and current profile to the applicable duty column, including acceleration, peaks, duration, and recovery. The 45 kW normal-use label should not be applied to a 37 kW heavy-duty requirement without this comparison.
An enclosure review shows limited cooling capacity; how should the 1129 W loss of ACS880-01-087A-3 3AUA0000108023 be evaluated?
Use the documented loss in the complete heat balance, not as an isolated figure. Include ambient temperature, other equipment, ventilation performance, airflow recirculation, and ABB derating requirements before accepting the enclosure.
If a process start drives ACS880-01-087A-3 3AUA0000108023 toward 122 A, which operating records are needed before the ramp is changed?
Capture output current, speed, torque reference, motor data, ramp command, load state, fault history, and supply condition. Compare the duration and repetition with the 87 A normal and 72 A heavy-duty basis before retuning.
What prevents an adjacent-frame drive from being treated as a mechanical substitute for ACS880-01-087A-3 3AUA0000108023?
R5 mounting, cable entry, terminal access, cooling, protection, current ratings, braking scope, I/O, options, firmware, parameters, and safety wiring all require comparison. A similar power label does not demonstrate interchangeability.
Which baseline information should maintenance receive after ACS880-01-087A-3 3AUA0000108023 passes its loaded acceptance test?
Retain identifiers, firmware, option codes, motor and duty data, final parameters, current and temperature readings, safety test results, network-loss behavior, fault history, drawings, backups, and the approved recovery process.