Features:
- The metric M14 x 1.5 probe case is unarmored and has a 50 mm overall length.
- A 1.0 m FluidLoc lead terminates in a protected miniature coaxial ClickLoc connector.
- The 11 mm sensing tip belongs to an extended-range 3300 XL non-contacting measurement system.
The complete ordering code uses 000 for a 0 mm unthreaded length and 050 for the 50 mm metric case.
PPS at the sensing tip and AISI 304 stainless steel in the case separate the target-facing surface from the threaded mounting body.
The 1.0 m probe resistance is specified at 5.9 ±0.5 ohms before the signal continues through the matching extension cable.
The Bently Nevada 330703-000-050-10-11-00 3300 XL 11 mm Proximity Probe may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 330703-000-050-10-11-00 3300 XL 11 mm Proximity Probe Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Three-Part Metric Geometry
- Mounting thread: The unarmored case uses an M14 x 1.5 external thread.
- Plain length: Code 000 indicates that the unthreaded section is 0 mm.
- Case length: The mandatory three-digit 050 option sets an overall length of 50 mm.
- Sensing face: An 11 mm PPS tip forms the target-facing end of the stainless-steel probe.
Extended-Range System Response
- Linear span: The complete 11 mm system covers 4.0 mm from approximately 0.5 to 4.5 mm target gap.
- Scale factor: Gap movement is converted at 3.94 V/mm within the stated system tolerance.
- Frequency path: The associated system response extends from 0 to 8 kHz with a typical -3 dB upper boundary.
- Target reference: System performance is specified against the documented AISI 4140 steel target.
FluidLoc Lead and Protected Joint
- Probe lead: Code 10 selects a 1.0 m total probe length.
- Fluid barrier: Option 11 applies FluidLoc construction to the triaxial FEP-insulated cable.
- Coaxial joint: A miniature ClickLoc connector couples the probe lead to the extension cable.
- Joint cover: The same option includes a protector around the connector pair.
Case Torque and Routing Boundaries
- Recommended torque: The M14 x 1.5 case is installed at 21.1 N-m.
- Thread depth: Internal engagement should not exceed 21 mm for the M14 case.
- Connector load: The rated tensile limit at the probe-lead to extension-cable joint is 270 N.
- Temperature boundary: Probe operation and storage are specified from -52 to +177 deg C.