Product overview:
- Non-contact eddy-current probe for static position and dynamic vibration measurement
- Metric M10 x 1 standard-mount body without protective armor
- TipLoc probe construction and CableLoc cable attachment improve mechanical robustness
The 330103-00-03-10-02-02 probe is one component of a complete 3300 XL 8 mm system. Use the correct Bently Nevada extension cable and Proximitor Sensor for the selected total electrical length.
Availability of the legacy -02 approval configuration is subject to OEM or Apter Power sourcing confirmation.
Bently Nevada 330103-00-03-10-02-02 Manuals and Datasheets
Important Notice: Other accessories, manuals, cables, calibration data and software are not included unless listed in the stock item description.
Exact ordering-code interpretation:
- 330103 - metric 3300 XL 8 mm probe, M10 x 1, without armor
- 00 - 0 mm unthreaded length
- 03 - 30 mm overall case length
- 10 - 1.0 m total probe length
- 02 - ClickLoc connector and standard cable without connector protector
- 02 - legacy multi-approval suffix
Current-order note: the current official 330103 table lists -05, not -02, for multi-approval orders. Verify certificates and nameplate markings before substitution.
Typical measurement applications:
- Radial shaft vibration on fluid-film bearing machines
- Axial or thrust position measurement
- Keyphasor phase-reference and speed measurement when applied per Bently Nevada guidance
- Non-contact measurement of conductive shaft surfaces
The standard 5 m 3300 XL 8 mm system complies with applicable API 670 performance requirements. This 1 m probe must be paired with the correct extension cable and Proximitor Sensor for the intended system length.
Installation and compatibility checks:
- Confirm the M10 x 1 mounting thread and 30 mm case-length clearance
- Observe the 25.4 mm minimum cable bend radius
- Use the correct extension cable and Proximitor Sensor to maintain total electrical length
- Confirm performance for target materials other than AISI 4140 steel
- Maintain suitable probe-tip spacing to limit cross-talk
Replacement check: match all option groups, system length, target material and approval requirements before installation.
Environmental and approval guidance:
- Standard probe operating and storage range: -52°C to +177°C
- Option 02 uses the standard FEP-insulated cable and ClickLoc connector without protector
- Current official 330103 ordering information lists -05 rather than legacy -02 for multi-approval orders
- Hazardous-area use depends on the delivered nameplate, certificates, wiring method and jurisdiction
Do not infer a hazardous-area rating from the part number alone. Verify the exact product markings and official approval documentation before installation.