Product overview:
- Standard-mount 3300 XL NSv proximity probe for tight installations and small-target measurement
- 1/4-28 UNF thread, without armor, with 0.5 in unthreaded length and 1.1 in overall case length
- 0.5 m standard FEP-insulated coaxial cable with protected ClickLoc connector
- Option 05 for multiple approvals
The Bently Nevada 330901-05-11-05-01-05 is one component of a complete 3300 XL NSv proximity transducer system. Pair it with the correct 3300 NSv extension cable and Proximitor Sensor for the required 5 m or 7 m system length.
Bently Nevada 330901-05-11-05-01-05 Manuals and Datasheets
Important Notice: Other accessories, manuals, cables, calibration data and software are not included unless listed in the stock item description.
Exact ordering-code interpretation:
- 330901: 3300 NSv probe, 1/4-28 UNF thread, without armor
- 05: 0.5 in unthreaded length
- 11: 1.1 in overall case length
- 05: 0.5 m (20 in) total probe length
- 01: miniature coaxial ClickLoc connector with connector protector and standard cable
- 05: multiple approvals
Configuration check: Match every option group in the complete part number before ordering a replacement probe.
Typical measurement applications:
- Radial vibration and radial position measurement on fluid-film bearing machines
- Axial or thrust position measurement where a small flat target is present
- Tachometer, zero-speed and phase-reference (Keyphasor) measurements
- Centrifugal air, refrigeration and process-gas compressors with restricted counterbore, side-view or rear-view clearance
The NSv system is intended for small shafts and reduced-clearance locations where conventional 5 mm or 8 mm probes may be difficult to install.
Installation and compatibility checks:
- Confirm the 1/4-28 UNF mounting thread and clearance for the 0.5 in unthreaded length and 1.1 in case length
- Observe the 25.4 mm (1.0 in) minimum cable bend radius and protect the coaxial connection
- Match the probe and extension cable lengths to the selected 5 m or 7 m 3300 XL NSv system length
- Use the recommended nominal gap and target material unless application-specific calibration data requires otherwise
- Check target size, counterbore dimensions, probe spacing and routing clearance before installation
Replacement check: Verify the complete ordering code, matched extension cable and Proximitor Sensor before commissioning the transducer loop.
Environmental and approval guidance:
- Standard probe operating and storage temperature range: -52°C to +177°C (-62°F to +351°F)
- Option 01 uses a standard FEP-insulated cable and protected miniature ClickLoc connector
- Option 05 specifies multiple approvals
- Hazardous-area suitability depends on the delivered nameplate, certificate, entity parameters and approved wiring method
Do not infer a complete hazardous-area rating from the part number alone. Verify the supplied documentation and installation requirements for the destination jurisdiction.