Product overview:
- Electromagnetic velocity transducer for casing-vibration measurement
- 0 degree nominal orientation with 10 Hz minimum frequency
- Top connector, isolated M10 x 1 base and ATEX/IECEx approvals
9200-06-01-11-04 is an electromagnetic Seismoprobe for direct measurement of absolute machinery casing vibration velocity. The option 06 mechanism is intended for a nominal 0 degree orientation within its documented angular tolerance.
A top-mounted connector and isolated circular M10 x 1 base define the installation interface. The transducer produces a self-generated velocity signal with 20 mV/mm/s nominal sensitivity over the documented 10 to 1000 Hz response band.
Mount the transducer on a rigid prepared surface, use the correct mating cable, and preserve shield and polarity conventions. Verify orientation, base isolation, channel scaling and certification before commissioning.
Verified resources for Bently Nevada 9200-06-01-11-04:
Configured ordering fields:
- 9200: Seismoprobe velocity transducer
- 06: 0 degree +/-100 degree orientation, 10 Hz minimum
- 01: top-mounted connector
- 11: isolated circular M10 x 1 base
- 04: ATEX/IECEx approvals
Use the complete 9200-06-01-11-04 reference when checking the nameplate, certificate or replacement request.
Signal details:
- Self-generated electromagnetic velocity output
- 20 mV/mm/s nominal sensitivity
- 10 to 1000 Hz frequency response
These details apply to the complete 9200-06-01-11-04 configuration and should be verified against the supplied unit.
Compatibility and matching:
- Use the correct two-socket Seismoprobe cable
- Configure the monitor for velocity sensitivity and polarity
- Preserve the isolated M10 x 1 mounting arrangement
Do not substitute 9200-06-01-11-04 until the mechanical, electrical and approval requirements have been matched.
Installation checks:
- Prepare a flat rigid mounting surface
- Observe the specified orientation range
- Verify wiring continuity, shield and calibrated channel response
Record mechanical, wiring and functional verification after installing 9200-06-01-11-04.