Features:
- Provides continuous monitoring of vibration, position, speed, and temperature.
- Customer-specific option requiring verification of exact specifications.
- CSA, ATEX, IECEx certified for installation in explosive atmospheres.
The 991-01-XX-01-05 MOD:284318-01 is a Turbine Supervisory Instrumentation (TSI) monitor card designed for the Bently Nevada 991 Series machinery protection system. It provides continuous, online monitoring of critical turbine parameters including vibration, position, speed, and temperature. The 991-01-XX-01-05 MOD:284318-01 is a rack-mounted module with LED status indicators for channel health and alarm conditions. This monitor card is essential for protecting steam, gas, and hydro turbines, as well as compressors and pumps, by providing early warning of developing faults and preventing catastrophic failures.
The "MOD:284318-01" suffix on the 991-01-XX-01-05 indicates a custom modification or customer-specific option, which may include special configuration parameters, firmware, or application-specific requirements. This customization allows the 991-01-XX-01-05 MOD:284318-01 to be tailored for unique installation conditions where standard cards may not be suitable. The exact specifications of the "MOD:284318-01" modification must be verified against the original order documentation or the product nameplate to ensure correct application. The 991-01-XX-01-05 MOD:284318-01 supports redundant power supply configurations for high availability.
The 991-01-XX-01-05 MOD:284318-01 carries CSA, ATEX, and IECEx approvals for hazardous area installations, making it suitable for use in refineries, chemical plants, and offshore platforms where explosive gases or dust may be present. The 991-01-XX-01-05 MOD:284318-01 is a discontinued spare part but remains available through aftermarket suppliers for maintaining legacy Bently Nevada 991 Series systems. This ensures continued operation of existing turbine monitoring installations without requiring a full system upgrade.
The 991-01-XX-01-05 MOD:284318-01 Bently Nevada Thrust Transmitter may still be available for purchase and support from Apter Power beyond
End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 991-01-XX-01-05 MOD:284318-01 Thrust Transmitter Manuals,
Datasheets, Drivers, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not
included with this equipment unless listed in the above stock item description. All prices are
shown in USD.
Bently Nevada 991-01-XX-01-05 MOD:284318-01 Thrust Transmitter Specs
General
- Manufacturer GE / Bently Nevada
- Model 991-01-XX-01-05 MOD:284318-01
- Condition New Original ready stock
- Product Family
991-01-XX-02-05,991-01-XX-01-CN,991-06-XX-01-00 169955-01
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not
included with this equipment unless listed in the above stock item description. All prices are
shown in USD.
- Centrifugal Air Compressors: Extensively used to monitor fluid-film thrust bearing degradation and prevent impeller-to-shroud rubbing.
- Industrial Pumps & Fans: Applied to multi-stage boiler feed pumps, high-capacity water pumps, and cooling tower fans where axial thrust tracking is mandatory.
- Small Steams Turbines & Motors: Utilized on balance-of-plant auxiliary machinery for basic shaft alignment trending.
- Not OK / Signal Defeat Circuit: Automatically overrides the 4-20 mA output and forces the control loop to a low fault status if the proximity probe fails, the cable is cut, or an electrical connector becomes loose, successfully preventing false machinery trip signals.
- Power-up Inhibit Circuit: Suppresses output data during initial powering stages to eliminate false alarm spikes triggered by line voltage transients.
- Dynamic Signal Access (PROX OUT): Features non-isolated PROX OUT and COM terminal pins along with a built-in coaxial connector. This allows technicians to plug in a portable analyzer (like a Bently Nevada SCOUT) to capture real-time gap voltage and dynamic vibration waveforms without disrupting the 4-20 mA protection loop.
- Mounting: The unit features a 35mm DIN-rail clip, allowing for easy installation in standard cabinets. It should be grounded to the metal chassis.
- Probe Connection: Connect the 3300 NSv Proximity Probe and extension cable (5 or 7 meters total) to the terminal block.
- Loop Power: Use a standard twisted, shielded pair for the 4-20 mA loop connection to the DCS/PLC, utilizing an external +24 VDC power supply.