Technical specifications for DU-2/MKIII

  • Manufacturer:
    DEIF
  • Part Number:
    DU-2/MKIII
  • Product Family:
    DEIF
  • Product Type:
    Additional Display Unit
  • Product Type:
    Additional display unit
  • Supported Platforms:
    Multi-line 2 and AGC-4 Mk II
  • Communication:
    CAN bus
  • Standard Displays:
    Up to three
  • Maximum CAN Length:
    200 m
  • Termination:
    End resistor required at bus ends
  • Nominal Supply:
    24 VDC
  • Supply Range:
    8-36 VDC
  • Front Protection:
    IP40 standard; IP54 with gasket
  • Safety Category:
    50 V CAT III
  • Housing Material:
    PC-ASA
  • Flammability:
    UL94-V0
  • Operating Temperature:
    -25 to +70 °C
  • Operator Interface:
    Menu-driven display and keys
  • Installation:
    Panel-mounted remote display
  • Weight:
    0.25 kg
  • Estimated shipping dimensions:
    22x12.4x3cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Denmark
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications CAN Connectivity Environmental Ratings Installation

Features:

  • Product type is set to Additional display unit.
  • The module's supported platforms are Multi-line 2 and AGC-4 Mk II.
  • The communication is CAN bus.
DU-2/MKIII combines product type of Additional display unit, supported platforms of Multi-line 2 and AGC-4 Mk II, and communication of CAN bus in the Multi-line 2 / AGC-4 Mk II platform.

It provides a remote operator display and control interface over the controller CAN bus. This role connects the Multi-line Additional Display Unit to the surrounding Multi-line 2 / AGC-4 Mk II architecture.

Before commissioning, verify the controller platform and display count; observe the 200 m CAN limit and termination rules; and match the supply, cutout and gasket requirement.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for DEIF DU-2/MKIII: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Adds a remote operating position to generator and power-management controllers.
  • Displays measurements, alarms and operating menus away from the main controller cabinet.
  • Supports marine and land-based switchboards where multiple operator stations share one CAN network.
  • The CAN network supports up to three connected display units.
  • Equipment operation requires 200 m for maximum CAN length.
  • The selected termination specification is end resistor required at bus ends.
  • For this hardware, the value for front protection is IP40 standard; IP54 with gasket.
  • The operating design assigns PC-ASA to housing material.
  • The specification for operating temperature is -25 to +70 °C.
  • For nominal supply, the selected value is 24 VDC.
  • This configuration uses 8-36 VDC for supply range.
  • The mounting arrangement is panel-mounted remote display.
Description
DEIF DU-2/MKIII is a Multi-line Additional Display Unit for the Multi-line 2 / AGC-4 Mk II platform. It provides a remote operator display and control interface over the controller CAN bus. The design preserves the hardware role required by the installed control platform.

The standard displays are Up to three. The maximum CAN length is 200 m. This combination helps engineers preserve the Multi-line Additional Display Unit's intended interface and operating role.

The termination is End resistor required at bus ends. The nominal supply is 24 VDC. These features provide a clear fit for Multi-line 2 / AGC-4 Mk II expansion, service, or lifecycle support.
Alternative Names
DU-2/MKIII DU-2 MKIII DU2MKIII DEIF DU-2/MKIII DEIF DU-2 display Multi-line DU-2 DU 2/MKIII DU-2/MKIII Multi-line Additional Display Unit
Technical notes
When installing DU-2/MKIII, observe the 200 m CAN limit and termination rules; match the supply, cutout and gasket requirement before returning the system to service.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What product type identifies DU-2/MKIII?
Product type is set to Additional display unit. This characteristic separates the Multi-line Additional Display Unit from visually similar hardware.
Which compatibility point matters most for DU-2/MKIII?
Confirm the Multi-line 2 / AGC-4 Mk II architecture, then verify the controller platform and display count. Compatibility depends on the installed interfaces and project configuration.
What operating role is suited to DU-2/MKIII?
Displays measurements, alarms and operating menus away from the main controller cabinet. The selected use must remain within the intended Multi-line 2 / AGC-4 Mk II architecture.
How is a sourcing request for DU-2/MKIII verified?
Provide clear nameplate photographs, required condition, quantity, destination, and the installed-system context. Apter Power can then review sourcing options.
Why is an engineered replacement review needed for DU-2/MKIII?
Do not assume a drop-in substitution. Observe the 200 m CAN limit and termination rules. Compare mechanical, electrical, communication, and software dependencies before approval.
What should buyers compare with the DU-2/MKIII datasheet?
Use the model-specific PDF in Manuals and compare the module's standard displays are up to three and the termination is end resistor required at bus ends with the installed equipment before requesting a quote.

Product Browsing History