Features:
- 2 CSLS units is the documented logic solvers for SS6502 as this redundant CHARMs Smart Logic Solver assembly.
- SS6502 uses a Redundant redundancy arrangement for this redundant CHARMs Smart Logic Solver assembly.
- Logic Solver CHARMs is the documented i/o architecture for SS6502 as this redundant CHARMs Smart Logic Solver assembly.
The current ordering configuration is SS6502, the DeltaV SIS Redundant CSLS Assembly identified for the DeltaV SIS Electronic Marshalling.
SS6502 performs the documented redundant CHARMs Smart Logic Solver assembly function within the DeltaV SIS Electronic Marshalling architecture. Its operation follows the capabilities and limits assigned to this exact ordering configuration.
Before commissioning, verify the complete redundant assembly, match baseplate and power modules, and validate safety application and proof-test requirements.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson SS6502:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Execute SIL 1, SIL 2, or SIL 3 safety instrumented functions in a redundant CSLS architecture.
- Process individually configurable LS CHARM channels while executing safety logic and built-in diagnostics.
- Implement distributed and scalable DeltaV SIS safety applications using two CSLS units and two power modules.
- SS6502 operates within the documented -40 to 70 degrees C temperature range for this redundant CHARMs Smart Logic Solver assembly.
- SS6502 supports 5 to 95%, non-condensing relative humidity for the documented redundant CHARMs Smart Logic Solver assembly.
- SS6502 has a documented protection rating of IP20 for this redundant CHARMs Smart Logic Solver assembly.
- Review the documented channel and device status after installing or replacing SS6502.
- Use the DeltaV SIS Electronic Marshalling diagnostic indications assigned to SS6502 when isolating a fault in its redundant CHARMs Smart Logic Solver assembly role.
- Use the DeltaV diagnostic indications associated with this redundant CHARMs Smart Logic Solver assembly when isolating a fault.
- Match SS6502 to the exact carrier, terminal, and I/O hardware documented for its DeltaV SIS Electronic Marshalling installation.
- SS6502 operates within DeltaV SIS Electronic Marshalling as the documented redundant CHARMs Smart Logic Solver assembly.
- Check the complete ordering code and hardware revision before replacing SS6502 with a similar assembly.