Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides Range 0 record review, sourcing, quotation, and SuperModule compatibility support.

3051S2CD0A

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson 3051S2CD0A is a Rosemount 3051S coplanar transmitter for very-low differential-pressure, flow, or level service requiring careful installation control.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 3051S2CD0A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3051S2CD0A

  • Manufacturer:
    Emerson
  • Part Number:
    3051S2CD0A
  • Product Family:
    Rosemount
  • Product Type:
    Rosemount Scalable Coplanar Differential Pressure Transmitter
  • Stock:
    1
  • Measurement Reference:
    Differential pressure
  • Sensor Range Code:
    0
  • Minimum Calibrated Span:
    0.10 inH2O (0.24 mbar)
  • Upper Sensor Limit:
    +3.0 inH2O (+7.45 mbar)
  • Lower Sensor Limit:
    -3.0 inH2O (-7.45 mbar)
  • Total Response Time:
    700 ms nominal for 4-20 mA HART
  • Dead Time:
    45 ms nominal
  • Update Rate:
    22 updates per second
  • Analog Output:
    Two-wire 4-20 mA
  • Digital Communication:
    HART digital signal superimposed on the analog output
  • Transfer Function:
    User-selectable linear or square-root output
  • External Power Supply:
    10.5-42.4 Vdc with no load
  • HART Communication Load:
    250 ohms minimum
  • Maximum Loop Resistance:
    43.5 x (power-supply voltage - 10.5) ohms
  • Mounting-Position Effect:
    Zero shift up to +/-1.25 inH2O (3.11 mbar), calibratable; no span effect
  • Overpressure Limit:
    750 psi (51.7 bar)
  • Static Pressure Limit:
    0.5 psia to the applicable range overpressure limit
  • Burst Pressure:
    10000 psig (689.5 bar) for coplanar or traditional flange
  • Ambient Temperature:
    -40 to +85 degrees C (-40 to +185 degrees F)
  • Storage Temperature:
    -46 to +85 degrees C (-50 to +185 degrees F)
  • Humidity Limit:
    0-100% relative humidity
  • Turn-On Time:
    Less than 2 seconds typical
  • Software Damping:
    0-60 seconds, user-selectable for one time constant
  • Volumetric Displacement:
    Less than 0.005 in3 (0.08 cm3)
  • Silicone-Fill Process Temperature:
    -40 to +100 degrees C (-40 to +212 degrees F) for differential-pressure range 0
  • Inert-Fill Process Temperature:
    0 to +85 degrees C (+32 to +185 degrees F) for differential-pressure range 0
  • Process-Port Pattern:
    1/4-18 NPT on 2-1/8 in centers
  • Electrical Entries:
    1/2-14 NPT, G1/2, or M20 x 1.5 according to the completed housing code
  • Enclosure Capability:
    NEMA Type 4X, IP66, and IP68 for the applicable housing configuration
  • Vibration Effect:
    Less than +/-0.1% of URL under the IEC 60770-1 test
  • Power-Supply Effect:
    Less than +/-0.005% of calibrated span per volt
  • Reference Configured Weight:
    6.3 lb (2.8 kg) with SST flange and junction-box housing, without options
  • Performance Class:
    Classic
  • Reference Accuracy:
    +/-0.035% of span under stated reference conditions
  • Rangedown:
    150:1
  • Long-Term Stability:
    +/-0.15% of URL for 15 years under stated reference conditions
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Compatibility Integration Certifications

Features:

  • The scalable SuperModule platform combines low-differential sensing with selectable electronics and coplanar integration.
  • Tiny leaks, unequal impulse legs, trapped liquid, valve bypass, or mounting stress can dominate a very-low differential measurement.
  • Stable temperature and vibration control are especially important where the measured differential is small.
The listed configuration is a scalable coplanar transmitter for very-low differential-pressure measurement; purchasing uses the complete device identity rather than appearance alone.

Within the plant system it performs sensitive process differential, flow, or level service on the Rosemount 3051S platform. Performance class 2 identifies Classic performance, while Range 0 is intended for very small differential spans.

Commissioning requires a documented check of the low-pressure manifold, performance class, mounting stress, sensing module, electronics, process seals, and approvals. Commission only after thermal stabilization and a verified zero under equalized process conditions.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson Rosemount 3051S2CD0A: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Monitors very small pressure losses across filters or clean process restrictions with carefully balanced impulse piping.
  • Supports low differential air or gas measurements when condensation and mounting stress are controlled.
  • Provides sensitive level or flow input after the complete primary-element and manifold arrangement is validated.
  • Manifold or adapter geometry is compared by part record and sealing arrangement, not by appearance.
  • Process and mechanical acceptance are completed for this scalable very-low DP assembly before electrical compatibility is considered.
  • Approval markings must suit the destination even when the measurement function is unchanged.
  • Process hardware is aligned and supported without using the transmitter body to correct piping mismatch.
  • The wired loop is tested end to end after enclosure entries are sealed.
  • Commissioning records the installed arrangement of this scalable very-low DP assembly.
  • The completed order code and nameplate together establish the approval scope for the installation.
  • Housing covers and approved conduit fittings form part of the certified protection method.
  • Any replacement is checked against manifold leakage, impulse balance, mounting stress, and approvals before hazardous-area acceptance.
Description
3051S2CD0A is supplied as a scalable coplanar transmitter for very-low differential-pressure measurement. Its physical label distinguishes the installed configuration from visually similar hardware.

In service, the assembly supports sensitive process differential, flow, or level service on the Rosemount 3051S platform. It resolves small process-pressure differences while supporting modular host and process connection choices.

Commissioning acceptance requires verification of the low-pressure manifold, performance class, mounting stress, sensing module, electronics, process seals, and approvals. Retain the checked configuration with the asset history.
Alternative Names
3051S2CD0A 3051S2CD-0A 3051S2CD 0A Rosemount 3051S2CD0A Emerson 3051S2CD0A EMR 3051S2CD0A Emerson Rosemount 3051S2CD0A Rosemount 3051S2CD0A Coplanar Differential Pressure Transmitter
Technical notes
3051S2CD0A is highly sensitive to mounting and static-head changes; equalize both sides and complete mechanical installation before the final zero trim.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which installation errors most strongly affect 3051S2CD0A at very low differential pressure?
Unequal impulse-line head, leakage, trapped fluid, manifold bypass, vibration, and mounting stress can create significant apparent differential.
Which low-pressure manifold condition is critical for 3051S2CD0A?
Match the coplanar manifold and confirm that its valves, passages, seals, and pressure rating suit sensitive measurement.
Where can 3051S2CD0A be used for very-low differential monitoring?
Use it for very-low differential service only where the process and installation can maintain a stable reference.
What preservation condition should be reported when sourcing stored 3051S2CD0A units?
Report storage condition, protective caps, calibration history, quantity, destination, delivery date, and complete nameplate details.
Why can a higher-range 3051S2CD not be treated as a drop-in replacement for 3051S2CD0A?
A higher-range sensing module changes resolution and calibrated behavior, so it is not a drop-in substitute without re-engineering.
Which 3051S performance document supports selection of 3051S2CD0A?
Use the Rosemount 3051S data sheet, reference manual, and manifold documentation for low-range installation and verification.

Product Browsing History