Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power can quote and source IC630CHS306 as a six-position base unit for GE Fanuc Series Three controller stations.

IC630CHS306

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC630CHS306 is the six-position Series Three base that supports a mid-size local or expanded I/O station.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC630CHS306
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC630CHS306

  • Manufacturer:
    General Electric
  • Part Number:
    IC630CHS306
  • Product Family:
    GE Intelligent Platforms
  • Product Type:
    Series Three 6-Position Base Unit
  • Stock:
    1
  • Supported arrangement:
    Local CPU or expansion base
  • Controller family:
    GE Series Three
  • I/O capacity:
    6 module positions
  • Supply location:
    Separate left-side position
  • Required supply count:
    One compatible supply for each base
  • Mains-powered supply:
    IC630PWR310, 115/230 VAC
  • DC-powered supply:
    IC630PWR314, 24 VDC
  • Supported base count:
    One, two, or three per Series Three I/O interface
  • 19-inch expansion cable:
    IC630CBL304
  • 3-foot expansion cable:
    IC630CBL305
  • 3-foot interface cable:
    IC630CBL530
  • Panel attachment:
    Four keyhole mounting points
  • Backplane service:
    Carries power and module connections
  • Supply separation:
    Dedicated position does not consume an I/O slot
  • Connector protection:
    Dust cover for unused expansion connection
  • Tariff Code:
    8538109000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Six Slots Backplane Base Chain Cabinet Fit

Features:

  • Carries six Series Three modules on a shared base backplane.
  • Reserves a separate left-side location for the compatible power supply.
  • Connects into one-, two-, or three-base arrangements through the Series Three I/O interface.
IC630CHS306 provides the six-position base format for either a processor rack or an expanded I/O section.

Backplane connections distribute supply rails and system interfaces across the installed module positions.

The available interface and expander cables determine how the base is incorporated into a multi-base cabinet layout.

Customers seeking the General Electric IC630CHS306 six-position Series Three base unit can request quotation support from Apter Power while the model retains active OEM lifecycle status.
General Electric IC630CHS306 Series Three 6-Position Base Unit Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Using the six-position module area

  • Capacity: The base provides six numbered locations for Series Three modules.
  • CPU use: A processor configuration can occupy the base when it is selected as the local controller section.
  • Expansion use: The same base format can carry I/O in an expanded section of the system.
  • Supply exclusion: Its dedicated power location remains outside the six-position module count.

Following power and module connections

  • Common path: The base backplane presents the Series Three interface to each installed module.
  • Rail distribution: Power from the fitted supply is carried across the module locations.
  • Module population: The six positions are populated according to the controller or I/O arrangement assigned to that base.
  • Supply separation: The left-side supply connection does not replace a numbered module position.

Choosing the expansion connections

  • Interface count: One Series Three I/O interface supports an arrangement of one, two, or three bases.
  • Interface cable: IC630CBL530 provides the three-foot lead from the interface to the base arrangement.
  • Short expansion: IC630CBL304 links adjacent bases across a 19-inch span.
  • Long expansion: IC630CBL305 provides a three-foot base-to-base connection when more spacing is required.

Arranging the base inside the cabinet

  • Panel fixing: Four keyhole openings secure the IC630CHS306 to the mounting surface.
  • Cable reach: The selected interface and expander lengths set the permissible spacing between linked bases.
  • Connector cover: An unused expansion connection remains protected by its dust cover.
  • Service access: The final position keeps the supply and all six module locations reachable for the assembled station.
Description
Providing six module locations in a Series Three assembly, the General Electric IC630CHS306 is the base unit that links the installed hardware through a common backplane.

The backplane carries both the module connections and the rails delivered by the fitted supply. Power enters through a separate left-side position, preserving all six numbered locations for the controller and I/O population.

A base uses one compatible power supply chosen for the available AC or DC source. Because every base is powered individually, an expanded controller arrangement adds supply responsibility together with the added module capacity.

One Series Three I/O interface can serve up to three linked bases through the specified interface and expansion cables. Four keyhole points anchor the assembly, while a dust cover protects an expansion connection that remains unused.
Alternative Names
IC630 CHS306 IC630-CHS306 IC-630-CHS-306 GE IC630CHS306 General Electric IC630CHS306 Series Three CHS306 IC630CHS3O6 IC63OCHS306
Technical notes
IC630CHS306 links up to three Series Three bases through the specified interface and expansion cables.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can IC630CHS306 extend a station without another power supply?
No. IC630CHS306 requires its own compatible supply even when it is connected to another Series Three base through expansion hardware.
Which supplies fit IC630CHS306 when it is used as a CPU base?
IC630CHS306 accepts IC630PWR310 for 115/230 VAC service or IC630PWR314 for a 24 VDC source in a local CPU-base arrangement.
How should the six positions of IC630CHS306 be recorded before modules are rearranged?
The numbered IC630CHS306 positions should be recorded with their installed modules so the physical order matches the controller configuration.
Which cable determines spacing between IC630CHS306 and another base?
IC630CHS306 uses IC630CBL304 for a 19-inch connection or IC630CBL305 for a 3-foot connection according to the required base spacing.
How many bases can share one station interface when IC630CHS306 is present?
An IC630CHS306 installation can include one to three Series Three bases connected through a station interface.
Why should the unused expansion connector on IC630CHS306 remain covered?
The IC630CHS306 dust cover protects the open expansion connection until another Series Three expander cable is installed.
Does IC630CHS306 assign I/O references without installed modules?
No. IC630CHS306 provides the physical positions, while the controller and installed module configuration determine the I/O reference allocation.

Product Browsing History