The General Electric IS210BPPBH2BKD is a auxiliary printed circuit board specifically engineered for the Mark VIe Speedtronic system, providing critical thermal monitoring and expanded processing resources for heavy-duty gas and steam turbines.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for IS210BPPBH2BKD
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IS210BPPBH2BKD

  • Manufacturer:
    General Electric
  • Part Number:
    IS210BPPBH2BKD
  • Product Family:
    GE Mark VIe Distributed I/O
  • Product Type:
    Turbine Auxiliary Processor Board
  • Stock:
    1
  • Diagnostics:
    Dual LED Status Indicators, Embedded Test Points
  • Sensor Accuracy:
    Temperature Sensing Element: ±2°C
  • PCB Coating:
    Conformal Coating (Humidity/Contaminant Protection)
  • Output Voltage:
    5V DC
  • Output Current:
    10A
  • Operating Temperature:
    -40°C to +85°C
  • Storage Temperature:
    -40°C to +100°C
  • Relative Humidity:
    5% to 95% (Non-condensing)
  • Weight:
    0.05 kg
  • Estimated shipping dimensions:
    11x7.5x2.2cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Applications Monitoring & Control Safety & Compliance

Features:

  • Deterministic Auxiliary Processing for Mark VIe
  • Ruggedized Conformal Coating & Thermal Tolerance
  • Deep Diagnostic Visibility with ±2°C Precision
The General Electric IS210BPPBH2BKD offloads thermal management and diagnostic tasks from the primary controller. By acting as a dedicated co-processor, it ensures that the main CPU remains focused on high-speed turbine protection logic (e.g., over-speed detection), reducing jitter and improving response times in emergency shutdown scenarios.

To survive the corrosive environments found in turbine enclosures, the General Electric IS210BPPBH2BKD utilizes a conformal coating that protects sensitive circuits from conductive contaminants. Rated for extreme temperatures (-40°C to +85°C) and high vibration, this board ensures continuous operation in combined-cycle plants without failure due to moisture ingress or thermal cycling fatigue.

Engineers can perform rapid fault isolation using the onboard dual-LED status indicators and physical test points on the General Electric IS210BPPBH2BKD. The integrated temperature sensor provides live monitoring with ±2°C accuracy, allowing the Mark VIe system to trigger predictive alarms before thermal stress warps the backplane connectors, thus preventing costly unplanned outages.

The IS210BPPBH2BKD General Electric Mark VIe Turbine Auxiliary Processor Board may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IS210BPPBH2BKD Mark VIe Turbine Auxiliary Processor Board Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
General Electric IS210BPPBH2BKD Mark VIe Turbine Auxiliary Processor Board

General

  • Manufacturer General Electric
  • Model IS210BPPBH2BKD
  • Condition New Original ready stock
  • Product Family IS210BPPCH1AEC,IS210BPPCH1AD,IS210BPPCH1ACA
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Heavy-Duty Gas Turbines (GE Frame 6FA/7EA): Executes auxiliary logic for inlet bleed heat control and compressor surge prevention, reducing load on the primary turbine controller.
  • Steam Turbine Retrofit Projects: Adds processing headroom for older turbines being modernized with digital electro-hydraulic (DEH) control systems.
  • Combined-Cycle Plants (CCPP): Serves as the data concentrator for heat recovery steam generator (HRSG) interface, synchronizing steam bypass logic with gas turbine output.
  • Offshore Power Generation: Its conformal coating makes it suitable for salty, humid environments where standard industrial cards fail within months due to galvanic corrosion.
  • Precision Thermal Feedback: The onboard ±2°C sensor provides direct analog input to the Mark VIe TMR (Triple Modular Redundant) safety logic, initiating runback procedures before the lubricating oil degrades.
  • Diagnostic Test Points (DTPs): Allows engineers to use oscilloscopes to measure logic-level signals (5V/10A rails) live, verifying power integrity during turbine startup without software polling delays.
  • Deterministic Data Bridging: Filters raw vibration data from proximity probes into usable "Peak-to-Peak" values via Modbus, offloading FFT calculations from the main CPU to maintain steady-state scanning.
  • Status Annunciation (LEDs): Offers "Heartbeat" and "Fault" indicators that blink in specific binary patterns to indicate exact failure modes (e.g., RAM corruption vs. Comm loss), even if the HMI is frozen.
  • IEC 61508 (SIL 2 Capable): Designed for use in Safety Instrumented Functions (SIFs) up to SIL 2 when integrated with the Mark VIe Safety Net, handling non-critical trips like high generator bearing temperature.
  • Dielectric Withstanding Voltage: The PCB material (FR-4 epoxy) is rated to withstand 1500V AC RMS for 60 seconds between primary power and ground, preventing arc flash propagation.
  • RoHS & REACH Compliance (Select Revisions): While some legacy units contain leaded solder, the General Electric IS210BPPBH2BKD "H2BKD" suffix typically corresponds to RoHS-compliant manufacturing for export to EU markets.
  • Vibration Resistance (IEC 60068-2-6): Tested to withstand 5g peak acceleration from 10-500Hz, ensuring solder joints do not crack under the low-frequency rumble of turbine skids.
Description
The General Electric IS210BPPBH2BKD functions as a specialized auxiliary/daughterboard within the Mark VIe control architecture. Designed to interface seamlessly with the WETA motherboard, this module offloads key processing tasks, ensuring deterministic data throughput for turbine protection logic. Unlike standard I/O cards, the IS210BPPBH2BKD acts as a computational bridge, managing real-time data communication between I/O packs and the system backbone to maintain ultra-low latency in critical control loops.

Built for the harsh realities of power generation, the General Electric IS210BPPBH2BKD features a conformal-coated PCB to resist humidity, dust, and chemical contaminants. The board integrates an AMD-based memory architecture and precision discrete semiconductors, operating reliably across a wide temperature range (-40°C to +85°C). Its ruggedized layout includes reinforced standoffs and shaped edges for secure seating in high-vibration turbine cabinets, preventing dislodging during seismic events or rotational imbalances.

Field engineers value the General Electric IS210BPPBH2BKD for its embedded diagnostic intelligence. It provides dual status LEDs and accessible test points for rapid root-cause analysis without requiring system shutdown. Thermally, it incorporates a ±2°C accuracy sensor feeding live data to the Mark VIe HMI, enabling predictive thermal management. This board supports Modbus and Profibus protocols, ensuring interoperability with existing plant DCS systems while executing turbine-specific speed/load control algorithms.
Revisions

Revision Part #

Also known as

IS210BPPBH2BKA
IS210BPPBH2B-KA, Series -KA, Rev -KA
IS210BPPBH2BKB
IS210BPPBH2B-KB, Series -KB, Rev -KB
IS210BPPBH2BKC
IS210BPPBH2B-KC, Series -KC, Rev -KC
Alternative Names
IS21OBPPBH2BKD 1S210BPPBH2BKD IS2I0BPPBH2BKD 1S2IOBPPBH2BKD IS210BPPCH1ACA IS210BPPCH1AD IS210BPPCH1AEC IS210BPPBH2BLD
Technical notes
The General Electric IS210BPPBH2BKD requires exact hardware revision matching (H2BKD suffix) for compatibility with existing Mark VIe racks; firmware must be aligned with the system's current ToolboxST version to prevent communication timeouts.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the specific communication protocol support for the General Electric IS210BPPBH2BKD when integrating with third-party DCS?
The General Electric IS210BPPBH2BKD supports Modbus RTU and Profibus DP via its modular communication jacks. It acts as a slave device on the Profibus network, passing turbine data (vibration/temperature) to a Siemens or ABB DCS, while maintaining deterministic Ethernet/EGD (Enhanced General Dynamic) protocol with the GE Mark VIe main controller.
What are the physical installation restrictions for the General Electric IS210BPPBH2BKD in a Mark VIe rack?
The General Electric IS210BPPBH2BKD is a vertical-mount board specific to the WETA motherboard slot. It requires a minimum clearance of 30mm front access for LED visibility and test point probing. Do not install this board in standard I/O slots; it is designed strictly as an auxiliary processor for the primary CPU rack to avoid bus contention.
Is the General Electric IS210BPPBH2BKD certified for use in ATEX/IECEx hazardous areas (Zone 2)?
While the General Electric IS210BPPBH2BKD itself is rated for general industrial locations (Class I, Div 2), it lacks intrinsic safety barriers for Zone 0/1. For gas turbine applications in petrochemical plants, it must be housed within a purged or Ex e certified enclosure that limits surface temperature to below the auto-ignition point of surrounding gases.