Technical specifications for MP60DP PME-MP60DP

  • Manufacturer:
    HBM
  • Part Number:
    MP60DP PME-MP60DP
  • Product Family:
    HBM
  • Supply Voltage:
    24 VDC
  • Data Formats Supported:
    16-bit integer, 32-bit integer, 32-bit floating point
  • Cyclical Output Data Options:
    Control word, Limit values 1–4
  • Diagnosis:
    External diagnosis, 4 bytes length
  • Configuration:
    Via GSD/GSE file or manual parameter assignment
  • Weight:
    0.9 kg
  • Estimated shipping dimensions:
    6x16.2x15.2cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.
Description
The MP60DP PME-MP60DP is an enhanced version of the MP60 measurement module, featuring integrated Profibus-DP communication capabilities. This module retains all the functionalities of the MP60, including high-precision measurement of mechanical quantities via carrier-frequency technology, while adding seamless integration into Profibus-based automation systems. 

Communication via the Profibus interface on the MP60DP PME-MP60DP follows the DP protocol, ensuring reliable and standardized data exchange with PLCs and other control devices. The module is configured using GSD/GSE files, which define its node properties and data structures for the Profibus network. 

Installation and operation of the MP60DP PME-MP60DP are straightforward. The device requires a 24 VDC supply voltage and is connected to the Profibus network via a shielded cable with proper termination resistors. The front panel includes a 9-pin D-sub connector for Profibus, alongside the existing CAN interface and transducer ports. 

The MP60DP PME-MP60DP is designed for robustness and flexibility in industrial environments. It supports cyclical data exchange with configurable input and output lengths, allowing users to select specific data contents such as status words, limit values, and control commands. 
Alternative Names
MP60CAN MP60PROFINET MP60MODBUS MP60A
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How do I configure the MP60DP PME-MP60DP for Profibus communication?
Configuration of the MP60DP PME-MP60DP is done using a GSD/GSE file (e.g., hbmxxx.gsd) provided with the device. In your PLC configuration tool (e.g., Siemens Step 7), load the GSD file, add the MP60DP as a Profibus node, and select the desired data format (16-bit integer, 32-bit integer, or floating point). The parameter assignment message defines settings such as diagnosis release, control bit enabling, and data format selection.
What is the maximum amount of cyclical data that can be exchanged with the MP60DP PME-MP60DP?
The MP60DP PME-MP60DP supports up to 13 words of input data and up to 9 words of output data in cyclical communication. The actual length depends on the selected data format (e.g., 32-bit values occupy 2 words each) and the configuration of measured values and control words as defined in the manufacturer-specific data of the configuration telegram.
How does the MP60DP PME-MP60DP indicate Profibus communication status?
The MP60DP PME-MP60DP provides visual status indication through its front-panel display and LED. The display shows messages such as “BD_SEAR” (baud rate search), “WT_PARM” (waiting for parameters), “WT_CONF” (waiting for configuration), “DATA_EX” (cyclic data exchange active), or “ERROR” (bus fault). The LED color corresponds to these states: green for DATA_EX, yellow for BD_SEAR/WT_PARM/WT_CONF, and red for ERROR.
Can I enable external diagnosis on the MP60DP PME-MP60DP, and what information does it provide?
Yes, external diagnosis can be enabled via the parameter assignment message by setting the diagnosis parameter to “released.” The MP60DP PME-MP60DP then provides a 4-byte diagnosis message, including version identification, device diagnosis flags, and detailed error bits for conditions such as hardware overflow, ADC overflow, signal overflows, scaling errors, and transducer faults.