Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power assists with F1 DI 16 01 pricing requests and official HIMA documentation access.

F1 DI 16 01

/ 4.9
1001 reviews | Need a Specific Revision?
HIMA F1 DI 16 01 is a HIMatrix safety-related digital input device with sixteen monitored digital inputs and four clock outputs.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for F1 DI 16 01
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for F1 DI 16 01

  • Manufacturer:
    HIMA
  • Part Number:
    F1 DI 16 01
  • Product Family:
    HIMA HIMatrix system
  • Product Type:
    HIMatrix Digital Remote I/O
  • Stock:
    1
  • Digital inputs:
    16 monitored channels
  • Clock outputs:
    2 channels
  • Communication:
    SafeEthernet
  • Network interface:
    Integrated Ethernet ports
  • Mounting:
    DIN-rail remote I/O
  • Input role:
    Safety-related binary acquisition
  • Diagnostics:
    Input and line monitoring
  • Line-monitoring support:
    Clock-output supervision
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Monitoring SafeEthernet Fault Diagnosis Applications

Features:

  • Sixteen safety-related digital inputs collect remote field-contact states.
  • Two clock outputs support the documented line-monitoring arrangements.
  • Two integrated Ethernet ports carry input data and diagnostics through SafeEthernet.
F1 DI 16 01 places monitored discrete acquisition close to shutdown switches, valve feedback contacts or guarded equipment.

The clock-output arrangement helps the configured application discriminate selected wiring faults from normal contact transitions.

Integrated switching lets the device join the HIMatrix network without a separate communication module.

Apter Power can assist buyers seeking HIMA F1 DI 16 01 HIMatrix safety-related remote input device and its official HIMA documentation.
HIMA F1 DI 16 01 HIMatrix safety-related remote input device Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

How F1 DI 16 01 Evaluates Field Contacts

  • Sixteen inputs: The device collects discrete safety signals from contacts and compatible 24 VDC sources.
  • Line monitoring: Configured supervision helps distinguish a valid process state from selected wiring faults.
  • Clock outputs: Two documented clock outputs support line-monitoring arrangements for connected inputs.
  • Logic value: Each input state and its diagnostic quality are transferred to the HIMatrix controller.

Connecting F1 DI 16 01 to the Safety Network

  • Two ports: Integrated Ethernet connections place the remote input device directly in a HIMatrix network.
  • Safety protocol: Input values and diagnostics are carried through SafeEthernet to the controller application.
  • Topology: The switched ports allow practical continuation of the network to another nearby device.
  • Project settings: Addressing and communication parameters must match the approved safety project.

Tracing an F1 DI 16 01 Input Problem

  • Channel state: Compare the reported input with the actual position of the field contact.
  • Supervised wiring: Use the configured line-monitoring indication to separate a wiring fault from a process transition.
  • Supply condition: Check the sensor or contact supply when several inputs change unexpectedly together.
  • Proof test: After repair, operate the field device and confirm the intended safety response.

Where F1 DI 16 01 Is Applied

  • Shutdown contacts: The remote inputs can collect trip switches close to process equipment.
  • Valve feedback: Limit contacts can confirm open, closed or safe positions to the safety logic.
  • Machine guarding: Guard switches and emergency-stop contacts can be grouped in a compact remote panel.
  • Burner interlocks: Discrete permissives can be monitored near the burner or packaged combustion skid.
Description
HIMA F1 DI 16 01 is a HIMatrix safety-related digital input device providing sixteen monitored digital inputs and four clock outputs.

Sixteen monitored inputs collect binary field states while four clock outputs support the input-monitoring functions documented for this compact HIMatrix device.

The clock-output assignments, line monitoring and SafeEthernet node configuration should be validated during commissioning.
Alternative Names
HIMA F1 DI 16 01 HIMatrix F1 DI 16 01 F1DI1601 F1-DI-16-01 HIMA F1DI1601 HIMA F1-DI-16-01 HIMA F1 DI 16 01 HIMatrix safety-related digital input device F1 DI 16 01 HIMatrix safety-related digital input device
Technical notes
F1 DI 16 01 uses two clock outputs for monitored input circuits; confirm the configured supervision response during loop commissioning and proof testing.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How do the clock outputs support line monitoring on F1 DI 16 01?
F1 DI 16 01 uses its documented clock signals in configured input circuits so selected wiring faults can be distinguished from contact changes.
Why can several F1 DI 16 01 inputs change state together?
A lost sensor supply or shared terminal connection can affect multiple F1 DI 16 01 channels at the same time.
How does F1 DI 16 01 send field states to a HIMatrix controller?
Through two integrated Ethernet ports, F1 DI 16 01 transfers input values and diagnostic quality over SafeEthernet.
What should be compared when an F1 DI 16 01 input appears incorrect?
Match the actual field-contact position and measured voltage with the channel state and line diagnostic reported by F1 DI 16 01.
Can F1 DI 16 01 continue a line network to another remote device?
Its integrated switched ports allow F1 DI 16 01 to form part of the documented HIMatrix Ethernet topology.
Which records are needed before replacing F1 DI 16 01?
Preserve the F1 DI 16 01 address, clock-output assignments, monitored-input configuration and complete terminal map.
How is F1 DI 16 01 returned to service after repair?
Operate each affected contact, verify the F1 DI 16 01 diagnostic state and complete the required proof test of the protective function.