MLI-DR30E

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell MLI-DR30E is a MasterLogic 50 plc base module with 18 digital inputs, 12 relay outputs and 100-240 V AC power.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for MLI-DR30E
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for MLI-DR30E

  • Manufacturer:
    Honeywell
  • Part Number:
    MLI-DR30E
  • Product Family:
    Honeywell MasterLogic-50
  • Product Type:
    PLC base module
  • Stock:
    1
  • Power supply:
    100-240 V AC
  • Digital input voltage:
    24 V DC
  • Digital input channels:
    18
  • Digital output channels:
    12
  • Output technology:
    Relay
  • Output logic:
    Relay contacts
  • Base-unit class:
    IEC E economic base unit
  • Programming standard:
    IEC 61131-3
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals I/O Data Communications Programming Installation Check

Product overview:

  • Integrated processor with 100-240 V AC power input
  • 18 digital inputs and 12 relay outputs
  • IEC E economic base unit for IEC 61131-3 control

MLI-DR30E combines controller processing, local digital I/O and its power stage in one compact Honeywell MasterLogic 50 assembly.

The relay contacts output arrangement must be matched to field polarity, load behavior and protective devices before wiring.

Communication planning covers Not integrated together with RS-232C or RS-485.

Apter Power can provide Honeywell MLI-DR30E for verified replacement and new-project requirements.

Verified resources for Honeywell MLI-DR30E:

I/O data:

  • Digital inputs: 18 channels at 24 V DC
  • Digital outputs: 12 channels
  • Output circuit: Relay, relay contacts

The onboard allocation of MLI-DR30E should be checked against the application point list and physical terminal map.

Expansion channels are engineered separately from the base-unit count and must agree with the saved project.

Communications:

  • Ethernet resource: Not integrated
  • Serial resource: RS-232C or RS-485
  • Retain verified addresses, protocols and cable assignments

Communication interfaces on MLI-DR30E support engineering and system data exchange appropriate to the configured MasterLogic network.

Test every required peer, supervisory and programming connection after hardware replacement.

Programming:

  • IEC 61131-3 control project
  • Preserve the validated program and parameter backup
  • Match hardware, firmware and I/O assignments

Load only the approved MLI-DR30E application after confirming the target hardware configuration.

Review diagnostics and perform controlled functional tests before enabling automatic operation.

Installation check:

  • Isolate power and identify every conductor
  • Verify supply, grounding, commons and terminal torque
  • Prove all I/O, communication and safety responses

After fitting MLI-DR30E, compare actual field voltage and load behavior with the documented design.

Record the installed revision, project backup, measured supply and commissioning results.

Description

MLI-DR30E is a Honeywell MasterLogic 50 plc base module with an integrated processor, 100-240 V AC power input, 18 24 V DC digital inputs and 12 relay outputs. The compact assembly combines controller execution, power conversion and local I/O for machine, utility and sequence-control applications.

The MLI-DR30E provides 30 onboard digital points before compatible expansion I/O is counted. The 12 relay channels provide contact switching for appropriately rated field circuits. Load voltage, steady current, inrush, switching frequency and suppression must be checked for every connected device. Communication resources include Not integrated and RS-232C or RS-485, so addressing and network parameters should be retained during replacement.

Before installing the MLI-DR30E, verify the complete nameplate, power class, terminal allocation, I/O commons, output wiring, connected expansion hardware, firmware level and approved application backup. Commissioning should include insulation and grounding checks, point-by-point I/O tests, controller diagnostics, communication tests and a controlled proof of the final machine sequence.

Alternative Names
MLI-DR30E MLI DR30E MLIDR30E Honeywell MLI-DR30E Honeywell MLI DR30E Honeywell MasterLogic 50 MLI-DR30E MLI-DR30E PLC base module Honeywell MLI-DR30E CPU I/O module
Technical notes
MLI-DR30E combines a 100-240 V AC supply, 18 digital inputs and 12 relay outputs in one Honeywell MasterLogic 50 base unit. Match the exact supply, output circuit, communication resources, expansion hardware and retained control project before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What power source is required for MLI-DR30E?
Use 100-240 V AC as marked for this base unit, with the documented protective device, grounding and available current verified before energization.
How are the 18 digital inputs on MLI-DR30E checked?
Confirm 24 V DC field polarity and the input common, then measure OFF and ON voltage at the terminal under the actual cable and contact conditions.
How should the relay outputs on MLI-DR30E be protected?
Check the load voltage, steady current, inductive or capacitive inrush and switching frequency, then use branch protection and suppression suitable for the connected device.
Which communication checks apply to MLI-DR30E?
Document the existing addressing and cabling for Not integrated and RS-232C or RS-485; restore only verified parameters and prove peer, supervisory and engineering access after replacement.
How is expansion I/O selected for MLI-DR30E?
Match the MasterLogic 50 expansion interface, available current, supported module count, terminal allocation and project configuration rather than relying only on the base-unit point total.
Can another MasterLogic 50 base unit directly replace MLI-DR30E?
Only after matching 100-240 V AC, the 18/12 I/O allocation, relay behavior, terminal layout, communications, firmware and application memory.
What tests are required after installing MLI-DR30E?
Inspect terminal torque, insulation, grounding and field power, test every input and output under controlled conditions, review diagnostics and prove the safe sequence before return to service.
What information is needed to quote MLI-DR30E?
Provide the exact nameplate, hardware and firmware revision, supply, connected I/O and communication details, expansion modules, quantity, destination and requested delivery date.