Technical specifications for F4-04AD

  • Manufacturer:
    Koyo
  • Part Number:
    F4-04AD
  • Product Family:
    Koyo
  • I/O Module Type:
    Analog Input
  • Number of Input Channels:
    4
  • Input Signal Types:
    Current and Voltage
  • Number of Non-Isolated Input Commons:
    1
  • Input Resolution:
    12-bit
  • Input Current Signal Ranges:
    4-20 mA, 0-20 mA
  • Input Voltage Signal Ranges:
    0-5 VDC, 0-10 VDC, 1-5 VDC, ±5 VDC, ±10 VDC
  • Burnout Detection Threshold:
    ~1.25 mA
  • Weight:
    0.32 kg
  • Estimated shipping dimensions:
    3.6x10x15cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.
Description
The F4-04AD is a versatile analog input module integrated into the DirectLOGIC DL405 series, providing reliable signal acquisition for industrial automation applications. With four isolated input channels, the F4-04AD accepts both current and voltage signals, including standard industrial ranges such as 4-20 mA, 0-20 mA, 0-5 VDC, 0-10 VDC, 1-5 VDC, and ±5/±10 VDC. 

A key feature of the F4-04AD is its built-in broken transmitter or burnout detection functionality, which operates specifically in 4-20 mA mode with a detection threshold of approximately 1.25 mA. This allows the F4-04AD to identify sensor or wiring failures promptly, enhancing system reliability and reducing downtime. 

The F4-04AD module requires an external 24 VDC power supply for operation, ensuring stable performance in demanding industrial environments. Configuration and programming of the F4-04AD are accomplished using DirectSOFT programming software version 4.0 or later, allowing users to easily set up input ranges, scaling, and diagnostic parameters. 

In summary, the F4-04AD stands out as a dependable and flexible analog input module for the DL405 series. Its combination of multi-range signal support, high-resolution conversion, and advanced diagnostic features like burnout detection makes the F4-04AD an ideal choice for applications in process control, environmental monitoring, and equipment automation. 
Alternative Names
F4-04DA F4-08AD F4-04RTD F4-04NA
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How does the burnout detection function work on the F4-04AD, and what is its threshold?
The burnout detection on the F4-04AD is active when the module is configured for 4-20 mA input mode. It monitors the input current and triggers a fault condition if the current drops below approximately 1.25 mA, indicating a broken transmitter or wiring issue. This status is then communicated to the PLC CPU for further action or annunciation.
What is the difference between the 16-bit and 32-bit modes for burnout indication on the F4-04AD?
The F4-04AD allows jumper selection between 16-bit mode and 32-bit mode for data and status handling. In 16-bit mode, a single multiplexed bit is used to indicate burnout status across channels (as detailed in manual page 3-15). In 32-bit mode, each channel has its own dedicated bit for burnout indication, providing more granular fault reporting (refer to manual page 3-18).
What input signal ranges are supported by the F4-04AD module?
The F4-04AD supports a wide variety of analog input ranges for both current and voltage signals. Current inputs can be configured for 4-20 mA or 0-20 mA. Voltage inputs accept 0-5 VDC, 0-10 VDC, 1-5 VDC, ±5 VDC, and ±10 VDC. This flexibility allows the F4-04AD to interface with most standard industrial sensors and transmitters.
What is required to power and program the F4-04AD module?
The F4-04AD requires an external 24 VDC power supply for proper operation. Configuration, scaling, and diagnostics are performed using DirectSOFT programming software version 4.0 or later. The module is designed as a sinking analog input type with non-isolated input commons, simplifying installation and integration into DL405 PLC systems.