    Keep your critical monitoring operations running smoothly with this reliable MURPHY I/O module, supplied by Apter Power to bridge the gap left by OEM obsolescence.

C3-1A E6-K-0115

/ 4.9
1001 reviews | Need a Specific Revision?
MURPHY C3-1A E6-K-0115 is a main I/O module that provides configurable control, monitoring, and signal processing for the C3 Series Centurion Controller in industrial automation applications.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for C3-1A E6-K-0115
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for C3-1A E6-K-0115

  • Manufacturer:
    MURPHY
  • Part Number:
    C3-1A E6-K-0115
  • Product Family:
    MURPHY
  • Product Type:
    Main I/O Module
  • Stock:
    1
  • Digital Inputs:
    32 optically isolated DC inputs
  • Analog Inputs:
    12 (4–20 mA or 0–5 V, 10-bit)
  • Thermocouple Inputs:
    8 (Type J or K, 12-bit)
  • Magnetic Pickup Input:
    1, 30 Hz to 10 kHz, 5 VAC rms min to 120 VAC rms max
  • Digital Outputs:
    10 (4 relay, 4 FET source, 2 IGBT sink)
  • Analog Outputs:
    2 × 4–20 mA, 16-bit (C3-1A only)
  • Power Input:
    10 -32 VDC.
  • Operating Temp.:
    -40 to 85° C (-40 to 185°F).
  • Configuration:
    PC-based software MConfigPro.
  • Weight:
    1.1 kg
  • Estimated shipping dimensions:
    8x18.6x26.1cm
  • Tariff Code:
    7113191100
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Operation Certifications Application Scenarios

Features:

  • Integrates 32 digital inputs, 12 analog inputs, 8 thermocouple inputs, one magnetic pickup input, and multiple digital and analog outputs in a single module.
  • Supports software-selectable I/O configuration through MConfigPro with no hardware jumpers required.
  • Expandable C3 Series architecture with Modbus® communication for HMI, PLC, PC, and SCADA integration.
MURPHY C3-1A E6-K-0115 is a configurable main I/O module developed for the C3 Series Centurion Controller, providing comprehensive control and monitoring functions for industrial automation systems. By combining digital, analog, thermocouple, and magnetic pickup interfaces, the module enables efficient collection of field data while delivering reliable output control. Auto-start capability further enhances automation by responding to pressure set points and digital commands.

The hardware supports demanding industrial environments with a 10–32 VDC power input and an operating temperature range from -40 °C to 85 °C. MURPHY C3-1A E6-K-0115 features software-selectable I/O configuration, LED status indication, open thermocouple detection, and cold junction compensation, reducing installation complexity while improving operational reliability. Factory-installed analog outputs provide precise signal control for advanced process applications.

MURPHY C3-1A E6-K-0115 also serves as the foundation of an expandable Centurion control platform. Additional I/O capacity can be added through the C3-2 expansion module, allowing larger compressor and pump control systems to be implemented without replacing the main controller. Combined with Modbus® communication support, the module offers an effective solution for modern industrial monitoring, remote supervision, and process automation.

The C3-1A E6-K-0115 MURPHY Main I/O Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
MURPHY C3-1A E6-K-0115 Main I/O Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
MURPHY C3-1A E6-K-0115 Main I/O Module Specs

General

  • Manufacturer MURPHY
  • Model C3-1A E6-K-0115
  • Condition New Original ready stock
  • Product Family C3-1,C3-2,C3-3
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Multi-channel Monitoring: Supports simultaneous refresh of 32 digital inputs and 12 analog inputs.
  • Speed ​​Control: Integrates 2 additional analog outputs for precise valve opening control.
  • High-Speed ​​Measurement: Built-in magnetic microphone (MPU) input enables real-time speed monitoring.
  • Wide Temperature Range: Strong environmental adaptability to meet harsh outdoor working conditions in extreme cold and heat.
  • Explosion-proof Certification: Passes Class I, Div 2 and other industrial hazardous area safety certifications.
  • Quality Standards: Complies with international heavy industry core controller manufacturing and testing standards such as ISO.
  • Rigorous Testing: Passes high-intensity industrial-grade vibration resistance and electromagnetic interference (EMI) tests.
  • Interconnection Standards: Fully compatible with Modbus RTU industry standard communication protocol specifications.
  • Natural Gas Pipeline Networks: Control of reciprocating compressor units for long-distance pipeline booster stations.
  • Oil and Gas Extraction: Safety monitoring of oil wellhead pumps and edge gas recovery systems in oil and gas fields.
  • Marine Propulsion: Operation parameter regulation and protection for large marine diesel generator sets.
  • Mining Machinery: High-reliability distributed control of heavy-duty mobile air compressor stations.
Description
MURPHY C3-1A E6-K-0115 is a main I/O module used in the C3 Series Centurion Configurable Controller, a control and monitoring system developed for engine-driven compressors, pump systems, and other industrial automation applications. The module continuously monitors input signals and set points while commanding output devices to maintain stable system operation. Auto-start functions allow equipment to start or stop automatically according to pressure set points or digital control signals.

MURPHY C3-1A E6-K-0115 integrates a wide range of I/O resources within a single module. It provides 32 optically isolated DC digital inputs, 12 analog inputs supporting 4–20 mA or 0–5 V signals with 10-bit hardware, 8 thermocouple inputs for Type J or Type K sensors with 12-bit hardware, and one magnetic pickup input operating from 30 Hz to 10 kHz with an input range of 5 VAC rms minimum to 120 VAC rms maximum. Open thermocouple detection and cold junction compensation improve measurement reliability for temperature monitoring applications.

The module also offers flexible output capability through 10 digital outputs consisting of four Form C relay outputs with dry contacts, four FET source outputs, and two IGBT sink outputs. As the C3-1A version, MURPHY C3-1A E6-K-0115 includes two factory-installed analog outputs supporting both 4–20 mA and 0–20 mA signals with 16-bit hardware. Each analog output uses dedicated screw terminal connections, providing accurate analog signal transmission for industrial control systems.

MURPHY C3-1A E6-K-0115 operates from a 10–32 VDC power input and supports an operating temperature range of -40 °C to 85 °C (-40 °F to 185 °F), allowing dependable performance in harsh industrial environments. All I/O functions are individually software selectable without hardware jumpers, simplifying configuration through the PC-based MConfigPro software. LED indicators provide clear status monitoring for digital inputs and outputs during operation.

As part of the expandable C3 Series platform, MURPHY C3-1A E6-K-0115 can be augmented with the C3-2 expansion module to increase analog outputs as well as additional analog and thermocouple inputs. Real-time operating data can be communicated to HMIs, PLCs, PCs, and SCADA systems using industry-standard Modbus® protocol, making the module suitable for reciprocating compressors, screw compressors, pump systems, and other industrial process control applications.
Alternative Names
C3-1A E6-K-0115 C3-IA E6-K-0II5 C3-1A E6-K-O115 C3-1 C3-3 C3-2
Technical notes
The MURPHY C3-1A E6-K-0115 is an advanced main I/O module featuring 32 digital inputs and 12 analog inputs, purpose-built for comprehensive engine protection. It streamlines midstream operations by integrating speed, pressure, and temperature monitoring into a single, high-reliability controller platform.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How does MURPHY C3-1A E6-K-0115 simplify system configuration?
All I/O options are individually software selectable through the PC-based MConfigPro configuration software, eliminating the need for hardware jumper settings.
Can MURPHY C3-1A E6-K-0115 communicate with SCADA or PLC systems?
Yes. MURPHY C3-1A E6-K-0115 supports real-time communication with HMIs, PLCs, PCs, and SCADA systems through the industry-standard Modbus® protocol.
Does MURPHY C3-1A E6-K-0115 include analog outputs?
Yes. MURPHY C3-1A E6-K-0115 includes two factory-installed 16-bit analog outputs supporting both 4–20 mA and 0–20 mA output signals.
Which input types are supported by MURPHY C3-1A E6-K-0115?
The module supports 32 digital inputs, 12 analog inputs, 8 thermocouple inputs for Type J or K sensors, and one magnetic pickup input operating from 30 Hz to 10 kHz.

Product Browsing History