CJ1W-OD261

/ 4.9
1001 reviews | Need a Specific Revision?
Omron CJ1W-OD261 is a CJ-series 64-point sinking transistor output unit with two Fujitsu/OTAX connector interfaces for high-density 12 to 24 VDC loads.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for CJ1W-OD261
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for CJ1W-OD261

  • Manufacturer:
    Omron
  • Part Number:
    CJ1W-OD261
  • Product Family:
    CJ-Series
  • Product Type:
    CJ-Series 64-Point Sinking Transistor Output Unit
  • Stock:
    1
  • Series:
    CJ-series
  • Module Type:
    Sinking transistor output unit
  • Output Points:
    64
  • Connector:
    Fujitsu / OTAX, two interfaces
  • Rated Load Voltage:
    12 to 24 VDC
  • Operating Load Range:
    10.2 to 26.4 VDC
  • Maximum Load Current:
    0.3 A per point
  • Maximum Common Current:
    1.6 A per common
  • Maximum Unit Current:
    6.4 A per unit
  • Inrush Current:
    3 A per point for 10 ms maximum
  • Leakage Current:
    0.1 mA maximum
  • Residual Voltage:
    1.5 V maximum
  • Response Time:
    0.5 ms ON, 1.0 ms OFF maximum
  • Circuit Grouping:
    Four circuits
  • Internal Current Consumption:
    170 mA maximum
  • Output Fuse:
    Not provided
  • External Supply:
    10.2 to 26.4 VDC, 50 mA minimum
  • Weight:
    0.11 kg
  • Estimated shipping dimensions:
    3.1 x 9.0 x 6.65 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    China
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Output Power Connector Mapping Fault Isolation Product Applications

Features:

  • High-density actuation: Sixty-four DC loads can be commanded from one compact CJ-series module position.
  • Four-circuit distribution: Grouped commons support structured connector wiring and load-current planning.
  • External protection boundary: The unfused output design makes polarity, branch protection and fault isolation explicit installation responsibilities.
CJ1W-OD261 is intended for dense banks of DC actuators, indicators and interface devices that use sinking transistor outputs.

Its two connector interfaces carry four output circuits, so the breakout hardware and common arrangement are part of the exact installation identity.

Commissioning should prove external supply polarity, one controlled load at a time, grouped current demand and controller mapping before production operation.

Apter Power can help confirm the Omron CJ1W-OD261 CJ-Series 64-Point Sinking Transistor Output Unit, connector interface and load-distribution scope before quotation.
Omron CJ1W-OD261 CJ-Series 64-Point Sinking Transistor Output Unit Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Supply polarity: Verify the external DC source before the connector is fitted to the module.
  • Common loading: Total the worst-case current for every output group, not only each individual load.
  • Branch protection: Provide suitable external protection because the module contains no output fuse.
  • Inductive loads: Confirm suppression and inrush behavior for valves, relays and other coils.
  • Exact connector: Retain the Fujitsu/OTAX interface specified for this model.
  • Dual-interface plan: Record which circuits and commons are assigned to CN1 and CN2.
  • Load labels: Preserve output identity before a breakout board or cable is removed.
  • Common continuity: Check every return path under load rather than relying on an unloaded voltage reading.
  • Whole-bank loss: Inspect the affected common, external supply and protective device first.
  • Single-load failure: Compare controller command, output indication, terminal voltage and field current.
  • Repeated damage: Find reverse polarity, overload or field shorts before installing another unit.
  • Intermittent output: Examine connector retention and inrush demand while the real load operates.
  • Solenoid banks: Commands qualified DC valves through protected connectorized wiring.
  • Machine indicators: Drives dense groups of lamps or interface signals within the published load limits.
  • Relay interfaces: Operates compatible DC relay coils with approved suppression.
  • Material handling: Controls conveyor and transfer devices from a compact CJ-series output position.
Description
CJ1W-OD261 provides sixty-four sinking transistor outputs in one narrow CJ-series position, distributing the field loads through two Fujitsu/OTAX connector interfaces.

Four electrically grouped output circuits make CJ1W-OD261 practical for high-density machine wiring, while each common and external supply must still be sized and protected for the real load pattern.

Because CJ1W-OD261 has no internal output fuse, commissioning and fault recovery depend on correctly polarized external power, suitable branch protection and a verified connector map rather than on module replacement alone.
Alternative Names
CJ1WOD261 CJ1W OD261 CJ-series 64-point sinking output unit
Technical notes
CJ1W-OD261 has no internal output fuse, and reversing the external supply can damage the module. Confirm connector polarity, branch protection and load current before energizing each common. When a bank fails, isolate the field short and prove the external supply rather than repeatedly replacing an unprotected output unit.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
A full group on CJ1W-OD261 stops operating while other outputs remain normal. What should be checked first?
Check the group common, external supply and branch protection before replacing the module. A shared power fault can remove sixteen healthy output channels together.
Can CJ1W-OD263 replace CJ1W-OD261 if both units provide many transistor outputs?
Do not assume so. Output form, connector interface, point grouping and electrical limits must match the installed wiring and controller allocation.
CJ1W-OD261 was damaged immediately after connector work. Which installation error is most critical to rule out?
Rule out reversed external-supply polarity and connector misalignment, then inspect field shorts and protection before another unit is energized.
A valve connected to CJ1W-OD261 chatters during switching. Is the PLC program the only likely cause?
No. Check supply stability, connector voltage under load, coil suppression, inrush demand and command timing before changing the sequence.
One CJ1W-OD261 output indicates ON but the field device stays off. How should the circuit be divided for diagnosis?
Confirm the controller command, module indication, pin voltage, common return and load current in order, using the approved wiring map.
What should purchasing specify when ordering CJ1W-OD261 for an existing panel?
State the exact model and verify that the Fujitsu/OTAX breakout connectors, cables, external protection and sinking-load arrangement are retained on site.