Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Product selection and manual requests for ATM90-PTG13X13 can be handled by Apter Power.

ATM90-PTG13X13

/ 4.9
1001 reviews | Need a Specific Revision?
SICK ATM90-PTG13X13 is an absolute multiturn encoder that converts shaft position and accumulated revolutions into PROFIBUS DP position data for machine control.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for ATM90-PTG13X13
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ATM90-PTG13X13

  • Manufacturer:
    SICK
  • Part Number:
    ATM90-PTG13X13
  • Product Family:
    SICK
  • Product Type:
    ATM90 Absolute Multiturn Encoder
  • Stock:
    1
  • Article Number:
    1030045
  • Mechanical Design:
    Through hollow shaft
  • Hollow Shaft Diameter:
    12 mm
  • Single-Turn Resolution:
    13 bit, 8192 steps per revolution
  • Multiturn Range:
    13 bit, 8192 revolutions
  • Measuring Step:
    0.043°
  • Error Limit:
    ±0.25°
  • Repeatability:
    0.1°
  • Communication Interface:
    PROFIBUS DP, DPV0
  • Encoder Profile:
    07hex, Class 2
  • Bus Address Range:
    0 to 127
  • Data Rate:
    9.6 kBaud to 12 MBaud, automatic detection
  • Supply Voltage:
    10 to 32 V DC
  • Power Consumption:
    ≤2 W without load
  • Maximum Speed:
    3000 rpm
  • Operating Temperature:
    -20 to +80 °C
  • Storage Temperature:
    -40 to +100 °C
  • Protection Rating:
    IP65 with shaft seal
  • Weight:
    1.76 lbs (0.8 kg)
  • Tariff Code:
    90318090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Position Data PROFIBUS DP Shaft Design Wiring & Climate

Features:

  • Thirteen-bit single-turn and thirteen-bit multiturn measurement preserve absolute shaft position.
  • PROFIBUS DP transfers position data at automatically detected rates from 9.6 kBaud to 12 MBaud.
  • The 12 mm through hollow shaft couples the encoder directly to the measured rotation.
SICK ATM90-PTG13X13 resolves 8192 positions per revolution and counts 8192 complete revolutions before the multiturn value repeats.

Address switches, protocol addressing, status LEDs, bus termination switches and a preset control support PROFIBUS commissioning.

The sealed encoder body operates from a 10 to 32 V DC supply and carries an IP65 rating when the shaft seal is fitted.

The SICK ATM90-PTG13X13 Absolute Multiturn Encoder may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
SICK ATM90-PTG13X13 Absolute Multiturn Encoder Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Absolute Position Word Structure

  • Single-turn value: Thirteen bits divide one shaft revolution into 8192 addressable positions.
  • Multiturn value: A separate thirteen-bit counter retains the position across 8192 complete revolutions.
  • Position granularity: The combined words identify angular position without requiring a homing cycle after power returns.
  • Reference setting: The preset input assigns a defined position value without changing the mechanical shaft coupling.

Bus Addressing and Commissioning

  • Network profile: DPV0 communication follows encoder profile 07hex Class 2 for position exchange.
  • Address assignment: A value from 0 to 127 can be selected by switches or assigned through the protocol.
  • Rate detection: The interface detects the active PROFIBUS rate from 9.6 kBaud to 12 MBaud.
  • Commissioning feedback: Status LEDs and termination switches expose bus state and end-of-segment setup separately.

Through Hollow Shaft Coupling

  • Mechanical coupling: The measured shaft passes through the 12 mm hollow opening instead of using a solid-shaft coupling.
  • Shaft material: The stainless-steel rotating surface is carried by the encoder bearing arrangement.
  • Speed limit: The complete mounted assembly is rated for shaft speeds up to 3000 rpm.
  • Housing support: The aluminum flange holds the encoder body while the hollow shaft follows the measured rotation.

Supply, Bus, and Environmental Limits

  • Supply input: A 10 to 32 V DC feed powers the encoder with no-load consumption limited to 2 W.
  • Bus termination: Termination switches must match the encoder position at the end or within the PROFIBUS segment.
  • Operating range: The installed encoder operates from -20 to +80 °C when its stated mechanical limits are observed.
  • Sealing condition: IP65 protection applies with the shaft seal installed around the rotating interface.
Description
SICK ATM90-PTG13X13 is an ATM90 absolute multiturn encoder that records the angular position within one revolution and the accumulated revolution count. The encoder sends both values through PROFIBUS DP so the controller receives a unique mechanical position after power is restored.

Position data in ATM90-PTG13X13 combines 13-bit single-turn resolution with a 13-bit multiturn range. This creates 8192 addressable steps per revolution across 8192 counted revolutions, while the preset function establishes the required machine reference without changing the shaft coupling.

A 12 mm through hollow shaft passes through ATM90-PTG13X13 and is secured by the encoder mounting arrangement. The stainless-steel shaft, aluminum flange and bearing system carry the mechanical rotation, and the permitted speed and acceleration limits apply to that complete rotating assembly.

PROFIBUS addressing for ATM90-PTG13X13 can be set from 0 to 127 by switch or protocol. Automatic data-rate detection covers 9.6 kBaud to 12 MBaud, while status LEDs, bus termination switches and the preset control provide separate commissioning feedback and setup points.

The 10 to 32 V DC input powers ATM90-PTG13X13 with no-load consumption limited to 2 W. With the shaft seal fitted, the IP65 enclosure and the specified -20 to +80 °C operating range define the allowable environmental conditions around the installed encoder.
Alternative Names
ATM90PTG13X13 ATM90 PTG13X13 ATM 90 PTG 13X13 SICK ATM90-PTG13X13 ATM90-PTG13X13 absolute encoder SICK ATM90 PROFIBUS encoder 1030045 ATM90 encoder ATM9O-PTG13X13
Technical notes
SICK ATM90-PTG13X13 combines 13-bit single-turn resolution with 13-bit multiturn counting and a 12 mm through hollow shaft. Its PROFIBUS DP interface transfers absolute position values to the controller.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does ATM90-PTG13X13 specify both 13-bit single-turn and 13-bit multiturn values?
ATM90-PTG13X13 uses the first 13 bits for 8192 positions within one revolution and the second 13 bits for 8192 counted revolutions.
How can the PROFIBUS address of ATM90-PTG13X13 be assigned during commissioning?
The ATM90-PTG13X13 address can be set from 0 to 127 by the device switches or through the PROFIBUS protocol.
Will ATM90-PTG13X13 require a manually selected PROFIBUS data rate?
No. ATM90-PTG13X13 automatically detects PROFIBUS rates from 9.6 kBaud to 12 MBaud.
What shaft arrangement must be prepared for ATM90-PTG13X13?
ATM90-PTG13X13 uses a 12 mm through hollow shaft, so the measured shaft passes through the encoder coupling opening.
When does the IP65 rating apply to ATM90-PTG13X13?
The IP65 rating for ATM90-PTG13X13 applies with the shaft seal installed and the encoder mounted within its environmental limits.
What is the purpose of the preset function on ATM90-PTG13X13?
The preset function on ATM90-PTG13X13 assigns a defined absolute position value at the current mechanical shaft position.