Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power supports 6GF3440-1CD10 with quotations, manuals, product selection, and model matching.

6GF3440-1CD10

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6GF3440-1CD10 is a SIMATIC MV440 SR stationary optical code reader that captures and evaluates 1D codes, 2D codes and text markings for identification tasks.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6GF3440-1CD10
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GF3440-1CD10

  • Manufacturer:
    Siemens
  • Part Number:
    6GF3440-1CD10
  • Product Family:
    SIMATIC MV
  • Product Type:
    SIMATIC MV440 SR Optical Code Reader
  • Stock:
    1
  • Image Sensor:
    1/3-inch CCD
  • Image Resolution:
    640 x 480 pixels
  • Image Capture:
    Global shutter
  • Exposure Control:
    Manual or automatic
  • Reading Range:
    70 to 3000 mm with matched optics
  • Lens Mount:
    C-mount
  • Illumination:
    Integrated or external
  • Maximum Capture Rate:
    80 Hz
  • Maximum Code Reading Rate:
    80 reads/s
  • Industrial Ethernet:
    M12 D-coded with PoE
  • Serial Interfaces:
    RS422 and RS232
  • Digital Inputs:
    5, including high-speed trigger
  • Digital Outputs:
    5, including high-speed strobe
  • Supply Voltage:
    24 V DC
  • Supply Range:
    19.2 to 28.8 V DC
  • Typical Current:
    0.27 A at 24 V DC
  • Protection Rating:
    IP67 with 6GF3440-8AC1X
  • Operating Temperature:
    0 to +50 °C
  • Status Display:
    5 LEDs
  • Weight:
    1.2125 lbs (0.55 kg)
  • Estimated shipping dimensions:
    6.8x12.2x4.5cm
  • Tariff Code:
    84719000
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Image Capture Interface Paths Trigger Timing Code Processing

Features:

  • A 640 x 480 global-shutter CCD captures the complete image before code or text processing begins.
  • C-mount optics and matched lighting adjust the field of view, working distance and mark visibility.
  • Ethernet, serial and configurable digital I/O separate data exchange from machine triggering and illumination timing.
The MV440 SR reads supported 1D and 2D codes and can use licensed text-recognition and verification functions.

A dedicated trigger input starts image capture while the strobe output synchronizes an external light source.

Five LEDs provide local status information for the reader and its active connections.

The Siemens 6GF3440-1CD10 SIMATIC MV440 SR Optical Code Reader may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GF3440-1CD10 SIMATIC MV440 SR Optical Code Reader Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Forming a readable image before decoding

  • Global shutter: The CCD exposes the complete frame at one instant instead of building it line by line.
  • Exposure control: Manual or automatic timing balances available light against motion and mark contrast.
  • Optical selection: C-mount lenses and accessories set the field of view for the required code size and distance.
  • Lighting path: Integrated or external illumination must make the marked surface visible without glare or shadow loss.

Separating network, serial and machine signals

  • Ethernet link: The M12 D-coded port carries industrial network data and supports PoE.
  • Serial equipment: RS422 and RS232 use separate connectors for devices that do not exchange data through Ethernet.
  • Power connector: The dedicated M16 supply connection accepts the reader's 24 V DC feed.
  • Machine I/O: A second M16 connection carries trigger, strobe and configurable digital-channel signals.

Coordinating capture with the moving process

  • Trigger edge: The high-speed input starts one defined capture event from the machine signal.
  • Strobe output: The fast output switches external lighting in time with that exposure.
  • Channel direction: Four additional isolated channels can be assigned as inputs or outputs for the installation.
  • Output boundary: Configured outputs are short-circuit protected and limited to the documented load current.

Matching recognition functions to the mark

  • Linear codes: The reader processes the enabled 1D symbologies from the captured image.
  • Matrix codes: Supported 2D formats are decoded from the same optical path after focus and exposure are established.
  • Text reading: OCR-A, Semifont M13 and similar fonts require the appropriate recognition function and image quality.
  • Verification mode: Enabled grading standards evaluate mark quality separately from simple decoding success.
Description
Siemens 6GF3440-1CD10 is the SIMATIC MV440 SR stationary optical code reader that captures image data and evaluates 1D codes, 2D codes, text and defined objects within an identification system. Its adjustable C-mount optics let the imaging area and working distance be matched to the marking being inspected.

Image acquisition in 6GF3440-1CD10 uses a 640 x 480 CCD with a global shutter, so the complete frame is exposed at one time before the internal recognition functions process it. Manual or automatic exposure control works with either the integrated lighting or an assigned external light source to make the code area readable.

Industrial Ethernet with PoE connects 6GF3440-1CD10 to the production network, while separate RS422 and RS232 interfaces serve serial communication paths. The dedicated supply and digital I/O connectors keep power, network data and machine-control signals on distinct electrical connections.

A high-speed trigger input tells 6GF3440-1CD10 when to record an image, and the high-speed strobe output synchronizes external lighting with that capture. Four additional opto-isolated channels can be assigned as inputs or outputs, while five LEDs present reader and connection status at the device.
Alternative Names
6GF34401CD10 6GF3440 1CD10 6GF 3440-1CD10 Siemens 6GF34401CD10 SIMATIC MV440 SR MV440 SR Code Reader Siemens Optical Reader 6GF3440-1CD10 6GF344O-1CD10
Technical notes
Siemens 6GF3440-1CD10 coordinates image capture through its trigger input and can time external lighting through the strobe output. Match the lens, illumination, working distance and enabled recognition function to the marking before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does 6GF3440-1CD10 trigger correctly but still fail to read a code?
For 6GF3440-1CD10, verify focus, exposure, illumination and that the enabled recognition function matches the printed or marked code type.
How should external lighting be synchronized with 6GF3440-1CD10?
Use the high-speed trigger input to start capture and the high-speed strobe output of 6GF3440-1CD10 to time the external light with that image.
Can 6GF3440-1CD10 communicate without using Industrial Ethernet?
Yes. 6GF3440-1CD10 also provides separate RS422 and RS232 serial interfaces, but their wiring and protocol settings must match the connected equipment.
What should be checked if digital I/O on 6GF3440-1CD10 does not switch as expected?
Confirm the 6GF3440-1CD10 channel direction, NPN or PNP input wiring, common connection and the 100 mA output limit before treating the reader as faulty.
How is the working distance of 6GF3440-1CD10 selected?
The C-mount lens and lens accessories set the field of view and working distance for 6GF3440-1CD10, so both must be matched to the code size and mounting position.
Which settings should be recorded before replacing 6GF3440-1CD10?
Record the 6GF3440-1CD10 network address, serial parameters, trigger and strobe assignments, I/O directions, exposure, focus and enabled recognition licenses.

Product Browsing History