Siemens 6GK5216-0BA00-2AA3 is a SCALANCE X216 managed switch that connects sixteen 10/100 Mbit/s Ethernet devices with redundant power and PROFINET diagnostics.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6GK5216-0BA00-2AA3
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GK5216-0BA00-2AA3

  • Manufacturer:
    Siemens
  • Part Number:
    6GK5216-0BA00-2AA3
  • Product Family:
    Siemens SCALANCE
  • Product Type:
    SCALANCE X216 Managed Industrial Ethernet Switch
  • Stock:
    1
  • Ethernet Ports:
    16 x RJ45
  • Port Data Rate:
    10/100 Mbit/s
  • Switching Method:
    Store and forward
  • PROFINET Role:
    IO device with diagnostics
  • Redundancy Manager:
    Integrated
  • Management:
    Web, CLI, SNMP, STEP 7
  • VLAN Support:
    IEEE 802.1Q
  • Port Mirroring:
    Supported
  • Configuration Memory:
    C-PLUG optional
  • Supply Inputs:
    2 x redundant
  • Rated Supply:
    24 V DC
  • Permitted Supply Range:
    18 to 32 V DC
  • Maximum Current Consumption:
    0.24 A
  • Power Loss at 24 V DC:
    5.76 W
  • Protection Rating:
    IP30
  • Operating Temperature:
    -40 to +60 °C
  • Storage and Transport Temperature:
    -40 to +70 °C
  • Weight:
    2.646 lbs (1.2 kg)
  • Estimated shipping dimensions:
    14x12.5x15cm
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Port Fabric Managed Traffic Redundancy Mounting & Climate

Features:

  • Sixteen RJ45 ports connect Industrial Ethernet devices at 10 or 100 Mbit/s.
  • Managed Layer 2 functions organize traffic, monitoring, and ring recovery.
  • Redundant 24 V DC feeds and a signaling contact expose supply degradation.
Siemens 6GK5216-0BA00-2AA3 forwards traffic through one sixteen-port managed switch fabric.

PROFINET and SNMP diagnostics on 6GK5216-0BA00-2AA3 report configured link and device events.

A C-PLUG can transfer saved configuration into a replacement 6GK5216-0BA00-2AA3.

The Siemens 6GK5216-0BA00-2AA3 SCALANCE X216 Managed Industrial Ethernet Switch may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5216-0BA00-2AA3 SCALANCE X216 Managed Industrial Ethernet Switch Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Sixteen-Port Ethernet Forwarding

  • Port group: Sixteen RJ45 interfaces connect 10/100 Mbit/s terminal or network devices.
  • Forwarding: Store-and-forward processing checks received frames before transmitting them.
  • Autonegotiation: Port speed and duplex follow the configured or negotiated link settings.
  • Diagnostics: Link, error, and packet statistics identify a local port fault before network-wide changes.

Configuration and Monitoring

  • VLAN control: IEEE 802.1Q divides the physical port set into configured logical networks.
  • Priority: Quality-of-service settings move selected traffic ahead of lower-priority frames.
  • Mirroring: Port mirroring copies selected traffic to a diagnostic connection.
  • Management: Web, CLI, SNMP, and STEP 7 provide separate setup and monitoring paths.

Power and Network Recovery

  • Supply inputs: Two 24 V DC feeds allow independent power paths.
  • Fault contact: The signaling contact reports selected supply or link conditions.
  • Ring manager: The integrated redundancy manager controls the configured ring role.
  • C-PLUG: Optional removable memory preserves the switch configuration for replacement.

Cabinet Installation Limits

  • Mounting: The enclosure supports standard rail, wall, or S7-300 rail installation.
  • Protection: IP30 requires the switch to remain within the intended cabinet environment.
  • Operating range: The documented ambient range is -40 to +60 °C.
  • Humidity: Operation permits up to 95 percent relative humidity without condensation.
Description
Siemens 6GK5216-0BA00-2AA3 is a SCALANCE X216 managed Industrial Ethernet switch with sixteen 10/100 Mbit/s RJ45 ports. It forwards plant-network traffic while exposing port state, error statistics, and topology information to management tools.

Two 24 V DC supply inputs on 6GK5216-0BA00-2AA3 provide redundant power paths. The signaling contact reports configured supply or port faults, allowing a degraded power feed to be identified even when the second source keeps the switch operating.

The integrated redundancy manager of 6GK5216-0BA00-2AA3 supports the configured ring behavior, while VLAN, prioritization, port mirroring, and SNMP organize traffic and diagnosis. PROFINET IO device functions transfer supported switch alarms into the automation project.

Mounted on a standard rail, wall, or S7-300 rail, 6GK5216-0BA00-2AA3 keeps all copper ports accessible from the cabinet front. A C-PLUG can retain configuration for replacement without changing the physical network connections.
Alternative Names
6GK52160BA002AA3 6GK5216 0BA00 2AA3 6GK 5216 0BA00 2AA3 Siemens 6GK5216-0BA00-2AA3 6GK5216-0BA00-2AA3 SCALANCE X216 6GK5216-0BA00-2AA3 Managed Ethernet Switch 6GK52I6-0BA00-2AA3 6GK5216-OBAOO-2AA3
Technical notes
Sixteen Fast Ethernet ports share the managed switch fabric of Siemens 6GK5216-0BA00-2AA3, while redundant supply inputs and a signaling contact expose power-path faults.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can 6GK5216-0BA00-2AA3 keep switching while reporting a power fault?
One redundant 24 V DC feed of 6GK5216-0BA00-2AA3 can fail while the second feed powers the switch and the contact reports degradation.
What should be saved before replacing 6GK5216-0BA00-2AA3?
Back up the 6GK5216-0BA00-2AA3 VLANs, priorities, ring role, port settings, IP configuration, SNMP data, and signaling-contact selection.
Why can PROFINET diagnostics fail although pings cross 6GK5216-0BA00-2AA3?
The 6GK5216-0BA00-2AA3 may forward Ethernet while device name, topology, VLAN, port mode, or PROFINET configuration remains inconsistent.
How should a ring interruption on 6GK5216-0BA00-2AA3 be investigated?
Review the 6GK5216-0BA00-2AA3 ring role, assigned ring ports, link states, cable order, partner settings, event log, and signaling contact.
Why can management access to 6GK5216-0BA00-2AA3 disappear while production traffic continues?
Incorrect 6GK5216-0BA00-2AA3 IP, VLAN, user, or access settings can block the management path without stopping unrelated switched frames.
What must match when moving a C-PLUG to 6GK5216-0BA00-2AA3?
Confirm the 6GK5216-0BA00-2AA3 hardware identity, firmware, C-PLUG state, saved configuration, port cabling, and planned startup behavior.