Features:
- Eight SFP positions add 100/1000 Mbit/s interfaces to an XM-400 switch.
- Two extender connections place the added ports inside the host switch configuration.
- Redundant supply support, hot-swappable transceivers, and DIN-rail mounting support modular operation.
Siemens 6GK5400-8AS00-8AP2 extends the physical port count of a compatible XM-400 assembly.
The host switch applies management and diagnostics to the SFP interfaces presented by 6GK5400-8AS00-8AP2.
Power and extender connections on 6GK5400-8AS00-8AP2 remain separate from the eight transceiver cages.
The Siemens 6GK5400-8AS00-8AP2 is a port extender for an XM-400 system and does not operate as a standalone switch.
Siemens 6GK5400-8AS00-8AP2 SCALANCE PE400-8SFP Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Eight Pluggable Network Paths
- Port count: Eight cages accept the documented SFP modules.
- Data rate: Each configured port operates at 100 or 1000 Mbit/s.
- Media choice: The selected SFP determines the supported cable and reach.
- Port state: The XM-400 host reports link and diagnostic status for each position.
Connection to the XM-400 Host
- Interfaces: Two extender connectors join the module chain.
- Management: The host switch owns configuration for the added ports.
- Topology: Physical extender order must match the documented assembly.
- Replacement: A replacement extender must retain the same system position and port mapping.
Supply and Module Consumption
- Redundancy: The supply arrangement supports redundant feeding.
- Power loss: The rated electronics loss is 1.7 W.
- Current: Maximum documented consumption is 0.07 A.
- Isolation: Power wiring remains separate from the optical transceiver interfaces.
Rail Position and Environment
- Rail: The extender mounts on a 35 mm DIN rail.
- Format: Its enclosure follows the SIMATIC S7-1500 device design.
- Cabinet: IP20 construction requires surrounding enclosure protection.
- Temperature: Operation is specified from -40 to 60 °C.