Features:
- 6SL3211-0AB13-7UA1 converts a 200–240 V single-phase line into a 0.37 kW three-phase output.
- The analog channel accepts a 0–10 V setpoint or can become a fourth digital input.
- Linear, square-law and parameterizable V/f modes define the motor-control path.
The 6SL3211-0AB13-7UA1 is the analog-input CPM110 variant within the SINAMICS G110 drive family.
Its input current, motor current and V/f settings belong to one 0.37 kW drive configuration and should not be mixed with neighboring G110 order numbers.
The IP20 FSA enclosure sets a cabinet boundary around the line, control and motor terminals.
The Siemens 6SL3211-0AB13-7UA1 SINAMICS G110 CPM110 AC Drive may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6SL3211-0AB13-7UA1 SINAMICS G110 CPM110 AC Drive Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Tracing energy from the line to the motor
- Line side: The drive accepts one AC phase at 200–240 V ±10%.
- Input demand: Rated line current is 6.20 A at the stated operating point.
- Motor side: The inverter produces a three-phase 0.37 kW output rated at 2.30 A.
- Conversion boundary: The line and motor ratings describe opposite sides of one drive and are not interchangeable.
Assigning commands to the analog variant
- Digital commands: Three dedicated inputs accept discrete drive-control signals.
- Analog setpoint: One scalable 0–10 V input carries the speed reference.
- Alternate assignment: The analog channel may instead operate as a fourth digital input.
- Status return: One isolated NPN optocoupler output reports a configured digital state.
Separating switching frequency from commanded output
- Pulse rate: The power stage uses an 8 kHz pulse frequency.
- V/f calculation: The documented control range extends from 0 to 650 Hz.
- Production limit: Legal stipulations cap the production configuration at 550 Hz.
- Control shape: Linear, square-law or parameterized V/f behavior is selected to suit the connected motor load.
Boundaries around the FSA enclosure
- Cabinet protection: The housing is IP20 and UL open type rather than a sealed field enclosure.
- Rated temperature: The data-sheet operating range is -10 to +40 °C.
- Altitude point: The stated installation altitude is 1,000 m.
- Moisture limit: Relative humidity may reach 95% only without condensation.