6SL3353-6TG41-2CA3

/ 4.9
1001 reviews | Need a Specific Revision?
Within a SINAMICS S line-module assembly, Siemens 6SL3353-6TG41-2CA3 is the control interface board for a 500–690 V, 1200 A Smart Line Module.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6SL3353-6TG41-2CA3
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6SL3353-6TG41-2CA3

  • Manufacturer:
    Siemens
  • Part Number:
    6SL3353-6TG41-2CA3
  • Product Family:
    Siemens SINAMICS
  • Product Type:
    SINAMICS S Control Interface Board
  • Stock:
    1
  • Assigned Power Unit:
    Smart Line Module
  • AC Voltage Class:
    500 to 690 V
  • Current Class:
    1200 A
  • Original Board Architecture:
    CIB
  • Replacement Architecture:
    CIM plus IPD
  • Replacement CIM:
    6SL3350-6TK00-0EA0
  • CIM Cooling Variant:
    Air-cooled power unit
  • Matched IPD Card:
    6SL3353-3AG41-2CA0
  • Configuration Level:
    p9=1
  • Component Comparison:
    p9906=3
  • Nonvolatile Save:
    p977=1
  • Weight:
    0.8818 lbs (0.4 kg)
  • Tariff Code:
    85049090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals CIB Function CIM + IPD Mapping Connector Transition Parameter Reconciliation

Features:

  • The CIB connects the Smart Line Module power hardware to its SINAMICS S control-side signals.
  • The documented replacement separates the original CIB functions between a common CIM and a matched IPD card.
  • Exact replacement mapping identifies both required order numbers for the 500–690 V, 1200 A module variant.
The replacement CIM provides the common control-interface electronics used by the conversion.

The IPD card adapts that common module to the electrical and connector requirements of the assigned power unit.

Parameter reconciliation accepts the changed component structure and stores it for later power cycles.

The Siemens 6SL3353-6TG41-2CA3 SINAMICS S Control Interface Board may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6SL3353-6TG41-2CA3 SINAMICS S Control Interface Board Manuals,Datasheets,Link Important Notice: No product manual is attached to this item. Other accessories, manuals, cables, calibration data, software, etc. are not included unless listed in the above stock item description. All prices are shown in USD.

Connecting the line-module power unit to drive control

  • Power-unit side: The board is assigned to the 500–690 V, 1200 A Smart Line Module configuration.
  • Control side: CIB circuitry provides the interface functions used by the SINAMICS S control arrangement.
  • Connector role: The original board carries the connection pattern used by the assigned line-module variant.
  • Variant boundary: The complete order number must be retained because voltage and current class determine the matched hardware.

Replacing one CIB with two coordinated parts

  • Common module: 6SL3350-6TK00-0EA0 supplies the CIM functions for the air-cooled power unit.
  • Matched interface: 6SL3353-3AG41-2CA0 is the IPD card assigned to this exact CIB variant.
  • Combined replacement: Neither order number alone represents the complete documented conversion.
  • Hardware check: Both parts must be compared with the original line-module rating before installation.

Preserving signal assignments during the conversion

  • Original layout: The CIB groups its control and power-unit connections on the original board arrangement.
  • New layout: The CIM and IPD divide those connections across two coordinated assemblies.
  • Plug change: New plastic connectors supplied with the replacement module must follow the documented terminal mapping.
  • Cable record: Connector position and signal assignment should be recorded before the original board is removed.

Accepting the changed component structure

  • Configuration level: Setting p9=1 opens the device-configuration stage used by the conversion.
  • Component check: p9906=3 performs the documented comparison for the replaced component class.
  • Completion: Returning p9 to zero leaves the configuration stage after the hardware is accepted.
  • Stored result: p977=1 writes the accepted configuration to nonvolatile memory for subsequent power-up.
Description
Siemens 6SL3353-6TG41-2CA3 is the SINAMICS S control interface board assigned to a 500–690 V, 1200 A Smart Line Module. It provides the control-side connection point between the line-module power hardware and the drive system signals that manage that power unit.

In the original arrangement, 6SL3353-6TG41-2CA3 combines the CIB electronics with the connector layout used by its Smart Line Module. The documented conversion separates those roles between a common Control Interface Module and a power-unit-dependent Interface Power Device card, so the connector hardware and control electronics are no longer treated as one replacement board.

For this exact variant, 6SL3353-6TG41-2CA3 maps to Control Interface Module 6SL3350-6TK00-0EA0 together with IPD card 6SL3353-3AG41-2CA0. Both parts belong to the same conversion because the CIM supplies the common interface functions while the IPD matches the 500–690 V, 1200 A Smart Line Module configuration.

After converting from 6SL3353-6TG41-2CA3, parameter p9 opens the device-configuration level and p9906 controls the component comparison. Returning p9 to zero completes that reconciliation, and p977=1 stores the accepted configuration in nonvolatile memory for the next power-up.
Alternative Names
6SL33536TG412CA3 6SL3353 6TG41 2CA3 6SL 3353-6TG41-2CA3 Siemens 6SL33536TG412CA3 SINAMICS S CIB 1200 A Smart Line Module CIB 6SL3353-6TG41-2CA3 Control Interface Board 6SL3353-6TG4I-2CA3
Technical notes
The documented conversion for 6SL3353-6TG41-2CA3 uses CIM 6SL3350-6TK00-0EA0 with IPD 6SL3353-3AG41-2CA0. Keep both order numbers and the existing connector assignment together during the conversion.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which two parts replace 6SL3353-6TG41-2CA3 in the documented conversion?
The 6SL3353-6TG41-2CA3 conversion uses CIM 6SL3350-6TK00-0EA0 together with IPD card 6SL3353-3AG41-2CA0.
Why is the IPD card required when replacing 6SL3353-6TG41-2CA3?
The common CIM handles the interface functions, while the matched IPD 6SL3353-3AG41-2CA0 adapts the replacement to the power-unit configuration originally served by 6SL3353-6TG41-2CA3.
What should be checked before disconnecting 6SL3353-6TG41-2CA3?
Record every connector position and cable assignment on 6SL3353-6TG41-2CA3 so the CIM and IPD conversion does not interchange control or power-unit signals.
How is the new component configuration accepted after removing 6SL3353-6TG41-2CA3?
After the 6SL3353-6TG41-2CA3 conversion, use p9=1, set p9906=3 for the comparison, then return p9 to zero before saving.
Why must p977=1 be used after the 6SL3353-6TG41-2CA3 conversion?
For the 6SL3353-6TG41-2CA3 replacement procedure, p977=1 stores the accepted device configuration in nonvolatile memory for the next power-up.
Does CIM 6SL3350-6TK00-0EA0 alone duplicate 6SL3353-6TG41-2CA3?
No. Replacing 6SL3353-6TG41-2CA3 requires both CIM 6SL3350-6TK00-0EA0 and the matched IPD 6SL3353-3AG41-2CA0.你