6GK7542-1AX00-0XE0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6GK7542-1AX00-0XE0 CM 1542-1 communication module for connecting SIMATIC S7-1500 to PROFINET.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for 6GK7542-1AX00-0XE0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6GK7542-1AX00-0XE0

  • Manufacturer:
    Siemens
  • Part Number:
    6GK7542-1AX00-0XE0
  • Product Family:
    Siemens Simatic S7-1500
  • Stock:
    1
  • Network:
    PROFINET / Industrial Ethernet
  • PROFINET Roles:
    IO Controller or IO Device
  • Communication Protocols:
    TCP/IP, ISO-on-TCP, UDP, S7
  • Network Services:
    IP broadcast/multicast, SNMPv1, NTP
  • Connectors:
    2 x RJ45, 10/100 Mbit/s
  • Weight:
    0.36 kg
  • Estimated shipping dimensions:
    Product dimensions: 3.5 x 12.9 x 14.2 cm.
  • Tariff Code:
    85176200
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications PROFINET Roles Open Ethernet CM 1542-1 Migration

Features:

•PROFINET connectivity for SIMATIC S7-1500 automation systems
•Configurable operation as a PROFINET IO Controller or IO Device
•Two RJ45 ports with TCP/IP, ISO-on-TCP, UDP, and S7 communication

The Siemens 6GK7542-1AX00-0XE0 extends a SIMATIC S7-1500 station with PROFINET communication through two 10/100 Mbit RJ45 interfaces.

The CM 1542-1 supports IO Controller or IO Device operation together with open Ethernet communication, S7 communication, SNMPv1, and NTP time synchronization.

Siemens identifies 6GK7542-1AX10-0XE0 as the successor. A replacement review should verify the controller project, device role, IP configuration, network topology, and commissioning requirements.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

Siemens 6GK7542-1AX00-0XE0 SIMATIC S7-1500 CM 1542-1 Specs

General

ManufacturerSiemens
Model6GK7542-1AX00-0XE0
ConditionNew and factory sealed
Product FamilySIMATIC S7-1500 CM 1542-1
•IO Controller: Siemens lists operation as a PROFINET IO Controller.
•IO Device: The module can also operate as a PROFINET IO Device.
•Ethernet ports: Two RJ45 interfaces support 10 and 100 Mbit/s connections.
•Controller family: CM 1542-1 is specified for SIMATIC S7-1500 systems.
•Open communication: TCP/IP, ISO-on-TCP, and UDP are included in the official protocol set.
•S7 communication: S7 communication is supported by the CM 1542-1.
•IP traffic: IP broadcast and multicast functions are listed.
•Diagnostics and time: SNMPv1 and NTP time synchronization are supported services.
•OEM status: Siemens lists 6GK7542-1AX00-0XE0 as discontinued.
•Successor: Siemens identifies 6GK7542-1AX10-0XE0 as the successor.
•PN review: Check the controller project, PROFINET role, IP configuration, and network topology before migration.
•Original article: Request an exact-model sourcing check when 6GK7542-1AX00-0XE0 must be retained.
Description
6GK7542-1AX00-0XE0 is the Siemens CM 1542-1 communication module for connecting a SIMATIC S7-1500 station to PROFINET. It supports operation as a PROFINET IO Controller or IO Device through two RJ45 ports rated for 10 or 100 Mbit/s.

6GK7542-1AX00-0XE0 supports TCP/IP, ISO-on-TCP, UDP, S7 communication, IP broadcast and multicast, SNMPv1 diagnostics, and NTP time synchronization for engineered Industrial Ethernet applications.

6GK7542-1AX00-0XE0 is listed by Siemens as discontinued with 6GK7542-1AX10-0XE0 identified as its successor. Confirm the exact article number, PROFINET role, controller project, and network requirements before replacement.
Alternative Names
6GK7542-1AX00-0XE0 6GK75421AX000XE0 6GK7542 1AX00 0XE0 6GK7 542-1AX00-0XE0 Siemens 6GK7542-1AX00-0XE0 SIMATIC 6GK7542-1AX00-0XE0 CM 1542-1 S7-1500 PROFINET module
Technical notes
Siemens 6GK7542-1AX00-0XE0 is the CM 1542-1 PROFINET module for SIMATIC S7-1500. Verify the IO role, network configuration, project compatibility, and exact article number before ordering.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What PROFINET information should a buyer provide when requesting 6GK7542-1AX00-0XE0?p
Provide the intended IO Controller or IO Device role, controller project context, device-name and IP plan, network topology, quantity, condition requirement, and destination.
How can an engineer verify the configured role of 6GK7542-1AX00-0XE0?
Review the S7-1500 hardware project and PROFINET configuration to confirm whether the module is assigned as an IO Controller or IO Device.
Why might a newly installed 6GK7542-1AX00-0XE0 not appear on the PROFINET network?
Check module and link status, Ethernet cabling, switch ports, device name, IP configuration, configured IO role, network topology, and controller diagnostics.
Can 6GK7542-1AX00-0XE0 be substituted with 6GK7543-1AX00-0XE0 without review?
No. CM 1542-1 and CP 1543-1 serve different communication and security requirements, so the complete project and network design must be reviewed.
What should be recorded before removing a failed 6GK7542-1AX00-0XE0?
Preserve the approved project, configured IO role, device names, IP settings, network topology, port connections, and available diagnostic records for recommissioning.
When is exact-model sourcing appropriate for 6GK7542-1AX00-0XE0?
It is appropriate when the approved project, validated machine configuration, or change-control process requires the original module until migration testing is complete.
How should a trader verify an offered 6GK7542-1AX00-0XE0?
Compare clear label and condition photos, the complete Siemens article number, traceability information, and quotation details with the buyer's installed-module record.
What assistance is available for a 6GK7542-1AX00-0XE0 inquiry?
Apter Power can provide quotations, matched technical documents, procurement support, exact-model checks, and PROFINET system-matching guidance.c