Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power offers 5464-340 quotes, documents, sourcing, and system-matching guidance.

5464-340

/ 4.9
1001 reviews | Need a Specific Revision?
Woodward 5464-340 Semi-Isolated RTD Input Module for MicroNet Isolated Input Modules.
In Stock
Ships by Saturday, October 31
Fast Shipping Available
Get a quick price for 5464-340
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 5464-340

  • Manufacturer:
    Woodward
  • Part Number:
    5464-340
  • Product Family:
    5400 Series
  • Product Type:
    Semi-Isolated RTD Input Module
  • Stock:
    1
  • Inputs:
    RTD 100 temperature inputs
  • Status:
    obsolete; inactivated after 31 July 2015
  • Replacement:
    LINKnet HT, RTCnet, or HDA alternatives require application review
  • Compatibility:
    legacy MicroNet input-module family
  • Environment:
    high-temperature RTD application
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Configuration Diagnostics Installation

Features:

  • Type: semi-isolated RTD 100 high-temperature input module
  • Inputs: RTD 100 temperature inputs
  • Status: obsolete; inactivated after 31 July 2015
The current ordering configuration is 5464-340. Legacy semi-isolated RTD 100 high-temperature input module identified by Woodward as obsolete and inactivated after July 2015.

For 5464-340, Woodward documents maintain temperature-input channels in an installed legacy MicroNet system and support spares planning for semi-isolated RTD measurement.

Select 5464-340 only where the project requires plan migration to documented current input architectures, following the official installation and commissioning instructions.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Woodward 5464-340:
  • Maintain temperature-input channels in an installed legacy MicroNet system
  • Support spares planning for semi-isolated RTD measurement
  • Plan migration to documented current input architectures
  • Replacement for 5464-340: LINKnet HT, RTCnet, or HDA alternatives require application review
  • Model-specific guidance: A replacement architecture may require line isolators and GAP changes.
  • Compatibility for 5464-340: legacy MicroNet input-module family
  • Model-specific guidance: Verify RTD type, isolation need, and fault response before migration.
  • Environment for 5464-340: high-temperature RTD application
  • Model-specific guidance: Do not treat current alternatives as drop-in replacements without engineering review.
Description
Woodward 5464-340 is a semi-isolated rtd input module. Legacy semi-isolated RTD 100 high-temperature input module identified by Woodward as obsolete and inactivated after July 2015.

The documented 5464-340 application covers maintain temperature-input channels in an installed legacy MicroNet system together with support spares planning for semi-isolated RTD measurement.

For 5464-340, verify the official Woodward requirements before using it for plan migration to documented current input architectures.
Alternative Names
5464340 5464 340 Woodward 5464-340 5464-340 Semi-Isolated RTD Input Module 5464-340 MicroNet Isolated Input Modules
Technical notes
5464-340: A replacement architecture may require line isolators and GAP changes. Verify RTD type, isolation need, and fault response before migration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which input arrangement applies to 5464-340?
Input arrangement: RTD 100 temperature inputs.
How is 5464-340 configured for replacement path?
LINKnet HT, RTCnet, or HDA alternatives require application review.
What system task is documented for 5464-340?
Support spares planning for semi-isolated RTD measurement.
Which project condition should be checked for 5464-340?
Plan migration to documented current input architectures.
What should buyers confirm about 5464-340 compatibility requirement?
Compatibility: legacy MicroNet input-module family.
What should buyers confirm about 5464-340 operating environment?
Operating environment: high-temperature RTD application.

Product Browsing History