Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, contact-form review, documentation, and DC-output matching.

ARM55C-000

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa ARM55C-000 is a rack-mounted 32-point dry-contact relay output board with selectable NO or NC contact use for CENTUM VP FIO Relay Boards.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for ARM55C-000
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ARM55C-000

  • Manufacturer:
    Yokogawa
  • Part Number:
    ARM55C-000
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    Mechanical Relay Board (32 Dry Contact Outputs)
  • Stock:
    1
  • Signal Service:
    Mechanical relay dry-contact output, NO or NC
  • Contact Points:
    32 points
  • Terminal Hardware:
    M3.5 screws; M4 at power input
  • Connectable Modules:
    ADV551 with ATD5A; ADV561
  • Signal Cables:
    AKB331 for 32-point; AKB337 for 64-point
  • Ordering Code:
    -000: 19-inch rack mountable, basic type
  • Contact Selection:
    Select either a-contact (NO) or b-contact (NC)
  • Maximum Load:
    30 V DC, 1.5 A per point
  • Minimum Load:
    5 V, 10 mA
  • Internal Circuit Supply:
    24 V DC, maximum 0.85 A
  • Insulation Resistance:
    At least 10 megohm at 500 V DC
  • Ambient Temperature:
    0 to 50 C
  • Relative Humidity:
    10 to 90% RH
  • Official Options:
    /BR3 wall mount bracket; /NTRY without cable tray
  • Weight:
    2 kg
  • Estimated shipping dimensions:
    48.26 x 13.25 x 7.54 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications NO/NC Review Terminal Fit Module Matching

Features:

  • Selectable contact form: Each application uses the documented normally open or normally closed path.
  • Thirty-two DC outputs: The official maximum load is specified for 30 V DC.
  • Distinct terminal hardware: Field outputs use M3.5 screws while the power input uses M4.

ARM55C-000 is the basic rack version of the Yokogawa 32-point dry-contact output board with selectable NO or NC use.

The 30 V DC load boundary and mixed M3.5/M4 terminal hardware must be checked against the installed wiring.

An RFQ should identify the contact form, output load, module and cable path, rack code, and complete nameplate.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

Yokogawa ARM55C-000 Mechanical Relay Board (32 Dry Contact Outputs) Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Yokogawa ARM55C-000 Mechanical Relay Board (32 Dry Contact Outputs) Specs

General

  • ManufacturerYokogawa
  • ModelARM55C-000
  • ConditionNew and factory sealed
  • Product FamilyCENTUM VP FIO Relay Boards

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Contact-form selection

  • NO path: Use the official a-contact arrangement when required.
  • NC path: Use the official b-contact arrangement when required.
  • Point record: Document the selected form for every output.
  • Replacement: Do not assume the installed contact form.

Field-terminal checks

  • Output screws: Confirm M3.5 field terminals.
  • Power input: Confirm the M4 supply connection.
  • Lug selection: Use the official solderless-lug dimensions.
  • Cabinet work: Verify clearance before transferring wiring.

FIO output path

  • ADV551: Check ATD5A and AKB331.
  • ADV561: Check the documented AKB337 arrangement.
  • Internal supply: Provide 24 V DC within 0.85 A.
  • Mounting: Confirm -000 rack or the separate /BR3 option.
Description

The Yokogawa ARM55C-000 is a rack-mounted 32-point dry-contact relay output board with selectable NO or NC contact use in the CENTUM VP FIO Relay Boards family.

Official documentation for ARM55C-000 confirms this configuration. Its M3.5 field terminals, M4 power input, and 30 V DC load rating distinguish it from the other ARM55 output boards.

Before ordering ARM55C-000, verify the selected NO or NC contact use, -000 rack code, 30 V DC load, terminals, module, and cable.

Alternative Names
Yokogawa ARM55C-000 ARM55C-000 ARM55C ARM55C 000 ARM55C000 ARM55C-000 Mechanical Relay Board (32 Dry Contact Outputs) ARM55C-000 CENTUM VP ARM55C CENTUM VP FIO Relay Boards
Technical notes
ARM55C-000 is a rack-mounted 32-point dry-contact relay output board with selectable NO or NC contact use. Confirm the complete suffix, connected hardware, and documented field interface before procurement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What output contact forms does ARM55C-000 support?
The official specification allows selection of a-contact (NO) or b-contact (NC) use.
What load is documented for ARM55C-000?
Yokogawa specifies a maximum of 30 V DC and 1.5 A per point, with a 5 V, 10 mA minimum load.
Which terminal sizes are used on ARM55C-000?
Field-device connections use M3.5 screws, while the power input uses M4 screws.
Which FIO modules are documented for ARM55C-000?
The listed paths use ADV551 with ATD5A or ADV561, plus the applicable signal cable.
Can ARM55D-000 be assumed equivalent to ARM55C-000?
No. Their contact form, terminal hardware, and official load ratings differ.
Where can I obtain the ARM55C-000 datasheet?
Open the verified PDF in Manuals and compare it with the installed nameplate.
How can I request ARM55C-000 price and stock?
Send the contact form, load, complete code, module path, cable, quantity, and destination.