ATD5A-00 S1

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa ATD5A-00 S1 is a 32-point digital I/O interface adapter for ADV151 or ADV551 modules using an AKB331 KS cable.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for ATD5A-00 S1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ATD5A-00 S1

  • Manufacturer:
    Yokogawa
  • Part Number:
    ATD5A-00 S1
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    Yokogawa digital I/O interface adapter
  • Stock:
    1
  • Channels:
    32
  • Compatible input module:
    ADV151
  • Compatible output module:
    ADV551
  • Required cable family:
    AKB331 KS cable
  • Surge option:
    -00: without surge absorber
  • Style:
    S1
  • Weight:
    0.1 kg
  • Estimated shipping dimensions:
    3.26x3.62x11.4cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Digital Interface Module & Cable Setup I/O Diagnostics Product Applications

Features:

  • 32-channel interface: one adapter routes a high-density discrete field connection
  • Input or output service: ADV151 and ADV551 arrangements use different field-circuit conditions
  • AKB331 cable path: the KS cable links the adapter channel allocation to the I/O module
Module focus: Identify input or output service before assigning power and commons.

Cable focus: Keep connector orientation and channel numbering consistent at both ends.

Diagnostic focus: Use the number of affected channels to distinguish shared from point faults.

Apter Power supports Yokogawa ATD5A-00 S1 interface adapter quotations, technical documents and digital I/O configuration review.
Yokogawa ATD5A-00 S1 32-point digital I/O KS cable interface adapter Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Input service: Use ADV151 channel logic, field voltage and common wiring.
  • Output service: Use ADV551 load-current and protection requirements.
  • Channel allocation: Keep terminal, cable and module channel numbers aligned.
  • Module: Confirm whether the installed hardware is ADV151 or ADV551.
  • Cable: Inspect the complete AKB331 cable code, connector orientation and locking.
  • Adapter: Mount ATD5A securely and protect connectors from side load.
  • Multiple channels: Check field supply, common wiring and both AKB331 connectors.
  • Single channel: Check the assigned conductor, field device and module diagnostics.
  • Intermittent state: Inspect connector retention, cable strain and electrical noise near the route.
  • Digital inputs: Connect status contacts and discrete sensors through an ADV151 module.
  • Digital outputs: Connect supported discrete loads through an ADV551 module.
  • Marshalling: Route thirty-two channels through a documented KS cable between cabinet sections.
Description
High-density discrete wiring reaches supported Yokogawa I/O modules through ATD5A-00 S1, a 32-channel interface adapter used with an AKB331 KS cable. The connected module defines whether the channel path serves ADV151 digital inputs or ADV551 digital outputs.

A complete ATD5A-00 S1 channel assignment spans the field conductor, adapter, cable connector and module point. Keeping those positions aligned is essential because input commons and output load circuits use different electrical conditions even though they share the same adapter format.

Fault patterns around ATD5A-00 S1 help direct diagnosis: many affected channels point toward shared field power, common wiring or an AKB331 connection, while one affected point directs attention to its conductor, field device and individual module diagnostic.
Alternative Names
ATD5A-00 S1 ATD5A-00S1 ATD5A 00 S1 Yokogawa ATD5A-00 S1 ATD5A S1 interface adapter ATD5A 32-point digital adapter ATD5A ADV151 adapter ATD5A ADV551 adapter
Technical notes
ATD5A-00 S1 is an interface adapter, so a multi-channel fault often indicates the AKB331 cable, connector seating, shared field supply or common wiring rather than thirty-two individual channel failures. Confirm whether the installed module is ADV151 or ADV551 before measuring the circuit.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can many channels connected through ATD5A-00 S1 fail at once?
Shared field power, common wiring or either AKB331 connector can affect a channel group. Check those common points and module status before tracing thirty-two field circuits individually.
How should a single failed point on ATD5A-00 S1 be diagnosed?
Compare the assigned field conductor, device state and individual module diagnostic while neighboring channels remain active. This isolates the point path from shared adapter and cable resources.
What happens if ATD5A-00 S1 is wired as an input adapter but the project uses ADV551 outputs?
Input and output modules apply different channel logic, field-power and load conditions. Stop commissioning and align the module type, project, common wiring and channel allocation before energizing the field circuit.
How can an AKB331 cable problem be distinguished from an ATD5A-00 S1 terminal problem?
Compare channel behavior at both ends of the cable and inspect connector retention and pin condition. A grouped fault that follows cable movement or one connector points to the interconnect path rather than individual field terminals.
What should be reviewed when an ADV551 output through ATD5A-00 S1 will not energize its load?
Check field supply, output allocation, load current, protection and the module diagnostic. Measuring the command and voltage at the assigned point distinguishes a disabled channel from an open load circuit.
Why can ADV151 inputs connected by ATD5A-00 S1 switch unpredictably?
An incorrect common, unsuitable field voltage, loose conductor or noise on the cable path can move the input across its switching threshold. Compare the terminal voltage with the module status under the actual field condition.
How should surge protection be planned for ATD5A-00 S1?
The -00 configuration has no integral absorber. Provide protection through the approved external design when the installation requires it, while keeping added devices compatible with the input or output circuit.