Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides project-matching support, official documentation, quotation and logistics.

PM564-RP-ETH 1SAP121000R0071

/ 4.9
1001 reviews | Need a Specific Revision?
ABB PM564-RP-ETH 1SAP121000R0071 is an AC500-eCo CPU with 128 kB user memory, onboard mixed I/O, relay outputs, RS-485 and Ethernet. It supports compact-machine control without requiring a separate basic I/O rack.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for PM564-RP-ETH 1SAP121000R0071
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PM564-RP-ETH 1SAP121000R0071

  • Manufacturer:
    ABB
  • Part Number:
    PM564-RP-ETH 1SAP121000R0071
  • Product Family:
    ABB AC500
  • Product Type:
    AC500-eCo CPU with Relay Outputs
  • Stock:
    1
  • Program memory:
    128 kB
  • Supply voltage:
    24 V DC
  • Digital inputs:
    6
  • Digital outputs:
    6 relay outputs
  • Analog inputs:
    2
  • Analog outputs:
    1
  • Ethernet interface:
    Integrated
  • Serial interface:
    RS-485
  • Weight:
    0.8818 lbs (0.4 kg)
  • Estimated shipping dimensions:
    13.5 x 8.2 x 7.4 cm
  • Tariff Code:
    85371091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Communication & Connectivity Programming Performance & Efficiency

Features:

  • The compact CPU includes mixed local digital and analog I/O.
  • Ethernet and RS-485 provide separate communication paths.
  • Relay outputs support direct switching within the published contact duty.
PM564-RP-ETH 1SAP121000R0071 combines an AC500-eCo processor, 128 kB user memory and onboard I/O.

It controls compact machines while exchanging data through Ethernet and serial networks from one module.

Archive the project and check relay loads, analog scaling, terminals and firmware before migration.

PM564-RP-ETH availability is confirmed for the complete 1SAP121000R0071 order code.
Verified resources for ABB PM564-RP-ETH 1SAP121000R0071:

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Controlling compact machines with onboard mixed I/O.
  • Connecting packaged equipment to Ethernet supervision and RS-485 devices.
  • Replacing a PM564 CPU while retaining documented terminal assignments.
  • Ethernet supports the configured plant or machine network connection.
  • RS-485 serves the documented serial protocol and node arrangement.
  • Addressing and protocol parameters are restored from the project archive.
  • The AC500-eCo application is backed up before hardware exchange.
  • Analog scaling and relay logic remain tied to the validated I/O map.
  • Firmware compatibility is checked before the project is downloaded.
  • Integrated I/O reduces separate-module count in compact panels.
  • Local execution keeps essential machine logic inside the controller.
  • Relay and analog channels share one documented commissioning plan.
Description
PM564-RP-ETH 1SAP121000R0071 combines an AC500-eCo processor with integrated digital and analog channels in a compact controller. The unit provides 128 kB of user memory together with six digital inputs, six relay outputs, two analog inputs and one analog output.

Ethernet and RS-485 interfaces allow the CPU to exchange plant data while retaining direct control of local sensors and relay-switched loads. This integrated layout suits small machines, packaged equipment and distributed panels where controller, communications and essential I/O must share a limited footprint.

Project transfer should include the application backup, firmware and communication settings as well as a field-by-field I/O check. Evaluate relay inrush, analog scaling, power supply and terminal allocation before substituting another PM56x CPU or energizing existing loads.
Alternative Names
PM564-RP-ETH PM564 RP ETH PM564RPETH 1SAP121000R0071 ABB PM564-RP-ETH ABB 1SAP121000R0071 AC500-eCo PM564-RP-ETH CPU ABB PM564 relay output Ethernet PLC
Technical notes
PM564-RP-ETH 1SAP121000R0071 relay outputs require load-specific inrush and suppression checks. Back up the AC500-eCo project and communication settings before replacing the CPU.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When should interposing contactors be used with ABB PM564-RP-ETH 1SAP121000R0071?
Use them when a field load exceeds the onboard relay contact duty, has high inrush, or requires isolation defined by the machine design.
How can ABB PM564-RP-ETH 1SAP121000R0071 keep serial and Ethernet traffic separated?
Plan the RS-485 node settings and Ethernet address scheme independently, then document which protocol and device group belongs to each interface.
What must be preserved before migrating an ABB PM564-RP-ETH 1SAP121000R0071 application?
Archive the project, firmware reference, retained data, communication parameters, analog scaling and relay fail-state assumptions.
Why should analog commons be reviewed on ABB PM564-RP-ETH 1SAP121000R0071?
The integrated analog channels must follow the documented grounding and reference arrangement to avoid measurement offsets or unwanted current paths.
How does the lifecycle classification affect ABB PM564-RP-ETH 1SAP121000R0071 planning?
The page status supports current sourcing review, but actual unit availability and delivery timing are confirmed by Apter Power for the requested order.
Which files accelerate an ABB PM564-RP-ETH 1SAP121000R0071 quotation for an existing machine?
Share the AC500-eCo project version, terminal schedule, network layout, full product label, quantity, destination and required commissioning date.

Product Browsing History