Features:
- High-performance control: The CPU provides 32 MB user program/data capacity and a 0.5 ms minimum cyclic-task setting.
- Flexible networking: Dual Ethernet, configurable serial, and CAN serve the documented control architecture.
- Revision 3 XC platform: R0378 is ABB’s active replacement for the earlier revision 2 article.
The processor is suited to coordinated machine and process workloads where actual task execution, communication load, and deterministic behavior must be measured rather than assumed.
A TB56xx-2ETH(-XC) terminal base supplies the I/O-bus and communication connections, with available expansion determined by the selected base model.
Project conversion, optional protocol licenses, network cycle settings, environmental protection, and recovery testing are central to a reliable deployment.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB PM5670-2ETH-XC 1SAP351000R0378 High-performance AC500-XC V3 Processor Module Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB PM5670-2ETH-XC 1SAP351000R0378 High-performance AC500-XC V3 Processor Module Specs
General
- ManufacturerABB
- ModelPM5670-2ETH-XC 1SAP351000R0378
- ConditionNew Original ready stock
- Product FamilyABB AC500-XC V3
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Execution-performance validation
- Task priority: Document every cyclic and event task before tuning.
- Jitter: Measure critical timing with communications and diagnostics active.
- I/O update: Align controller tasks with fieldbus and module update rates.
- Evidence: Retain performance traces with the accepted project.
Deterministic communication checks
- Protocol role: Confirm the licensed controller, master, scanner, or adapter duty.
- Topology: Record devices, switches, addresses, cable routes, and redundancy.
- Cycle parameters: Validate controller and device timing together.
- Recovery: Test network restart and safe machine behavior.
Revision 3 migration workflow
- Tool version: Use an ABB-supported Automation Builder release.
- Hardware target: Select the exact R0378 processor in the project.
- Firmware: Apply ABB rules when mixed revisions share an application.