SDCS-CON-H01 3ADT220166R0002
SDCS-CON-H01 3ADT220166R0002
SDCS-CON-H01 3ADT220166R0002
SDCS-CON-H01 3ADT220166R0002
SDCS-CON-H01 3ADT220166R0002
SDCS-CON-H01 3ADT220166R0002
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    ABB SDCS-CON-H01 3ADT220166R0002 quotations and product manuals are supported by Apter Power.

SDCS-CON-H01 3ADT220166R0002

/ 4.9
1001 reviews | Need a Specific Revision?
ABB SDCS-CON-H01 3ADT220166R0002 is the control board and electronic tray assembly used by DCS880 and DCT880 power units.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for SDCS-CON-H01 3ADT220166R0002
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for SDCS-CON-H01 3ADT220166R0002

  • Manufacturer:
    ABB
  • Part Number:
    SDCS-CON-H01 3ADT220166R0002
  • Product Family:
    ABB DCT 880
  • Product Type:
    DCS880/DCT880 Control Board and Electronic Tray Assembly
  • Stock:
    1
  • Assembly Type:
    Control board on hinged electronic tray
  • Memory Unit Connector:
    X205
  • Control Panel Connector:
    X13
  • Safety Option Connector:
    X12
  • DCSLink Option Connector:
    X200
  • Analog Input Header:
    XAI
  • Analog Output Header:
    XAO
  • Digital Input Header:
    XDI
  • Digital I/O Header:
    XDIO
  • Encoder Header:
    XENC
  • Safe Torque Off Header:
    XSTO
  • Relay Outputs:
    XRO1–XRO3
  • Jumper Set:
    J1–J7
  • Type Code Parameter:
    95.16
  • Supervision:
    Internal watchdog
  • Weight:
    4.189 lbs (1.9 kg)
  • Estimated shipping dimensions:
    26x29.5x6cm
  • Tariff Code:
    8538900000
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Tray Access Memory Transfer Connector Map Watchdog State

Features:

  • ABB SDCS-CON-H01 3ADT220166R0002 combines the control board with the hinged DCS880/DCT880 electronic tray.
  • Memory, option, panel and I/O connectors converge on the same control assembly.
  • An internal watchdog resets firing control and freezes documented outputs after a trip.
The service procedure treats the control board and tray as one assembly, not as an unconfigured loose PCB.

Jumper positions and the stored type code preserve hardware identity when the assembly is exchanged.

Named headers separate memory, panel, safety, DCSLink, feedback and control wiring so each connection can be returned to its original position.

The ABB SDCS-CON-H01 3ADT220166R0002 DCS880/DCT880 Control Board and Electronic Tray Assembly may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
ABB SDCS-CON-H01 3ADT220166R0002 DCS880/DCT880 Control Board Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Opening the control assembly without losing connections

  • Front access: The control panel and design cover are removed before the hinged tray is opened.
  • Option removal: Installed option modules are identified and disconnected from their slots.
  • Cable release: Flat cables and I/O plugs are removed from their marked headers rather than pulled as one harness.
  • Grounding path: Grounding screws are separated before the electronic tray is lifted from the power unit.

Retaining the drive identity during control-unit exchange

  • X205 memory: The memory unit is disconnected from X205 before the old tray is removed.
  • Jumper record: Positions J1 through J7 are copied from the existing control board.
  • Type code: The value associated with parameter 95.16 is recorded before replacement.
  • Reassembly: Memory, jumper and type-code information are returned to the replacement assembly before operation.

Assigning each external path to its control header

  • Panel and memory: X13 serves the control panel while X205 carries the memory unit.
  • Option paths: X12 and X200 are assigned to the documented safety and DCSLink options.
  • Signal headers: XAI, XAO, XDI and XDIO separate analog and digital field paths.
  • Control outputs: XENC, XSTO and XRO1–XRO3 connect feedback, safe-torque-off and relay circuits.

Control behavior after internal supervision trips

  • Firing control: A watchdog trip resets and disables the firing-control path.
  • Input processing: Digital and analog input values are no longer processed after the trip.
  • Digital outputs: Their last documented states remain frozen during the watchdog condition.
  • Analog outputs: The analog output values are likewise held rather than recalculated.
Description
ABB SDCS-CON-H01 3ADT220166R0002 is the control board supplied on the hinged electronic tray for DCS880 and DCT880 power units. The assembly carries the control electronics separately from the converter power section while presenting the connectors used by the panel, memory unit, option modules and drive I/O.

Service access to SDCS-CON-H01 3ADT220166R0002 begins at the electronic tray: the control panel and design cover are removed before the tray is opened. Plugs, flat cables, grounding points and installed option modules are disconnected from their identified positions so that the complete control assembly can be exchanged without treating the board as a loose generic PCB.

The X205 connection links the memory unit to SDCS-CON-H01 3ADT220166R0002, while the option slots and I/O headers connect communication, feedback and control circuits. Before replacing the assembly, the J1–J7 jumper positions and the type-code value associated with parameter 95.16 must be recorded and restored to retain the documented hardware configuration.

An internal watchdog supervises SDCS-CON-H01 3ADT220166R0002. If that watchdog trips, firing control is reset and disabled, digital and analog inputs are no longer processed, and the documented digital and analog outputs remain frozen until the control condition is cleared.
Alternative Names
SDCSCONH01 3ADT220166R0002 SDCS CON H01 3ADT220166R0002 ABB SDCS-CON-H01 ABB 3ADT220166R0002 3ADT220166R0002 Control Board SDCS-CON-H0I 3ADT220166R0002 DCS880 SDCS-CON-H01 DCT880 SDCS CON H01
Technical notes
ABB SDCS-CON-H01 3ADT220166R0002 integrates the DCS880/DCT880 control board, memory-unit connection, option slots, I/O headers, and watchdog supervision on one electronic tray.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why should ABB SDCS-CON-H01 3ADT220166R0002 be identified as a tray assembly rather than only a board?
ABB SDCS-CON-H01 3ADT220166R0002 is supplied on the hinged electronic tray, which carries the control board and its connected control interfaces.
What information must be recorded before exchanging ABB SDCS-CON-H01 3ADT220166R0002?
Record the J1–J7 jumper positions and the type code associated with parameter 95.16 before removing ABB SDCS-CON-H01 3ADT220166R0002.
Where is the memory unit connected on ABB SDCS-CON-H01 3ADT220166R0002?
The memory unit plugs into X205 on ABB SDCS-CON-H01 3ADT220166R0002 and is removed before the tray assembly is exchanged.
Which connections require tracing when ABB SDCS-CON-H01 3ADT220166R0002 is removed?
Trace the flat cables, I/O plugs, panel lead, option modules, memory unit and grounding points attached to ABB SDCS-CON-H01 3ADT220166R0002.
What happens to firing control after an internal watchdog trip on ABB SDCS-CON-H01 3ADT220166R0002?
A watchdog trip resets and disables firing control on ABB SDCS-CON-H01 3ADT220166R0002 and stops further digital and analog input processing.
How are outputs treated during the documented watchdog condition on ABB SDCS-CON-H01 3ADT220166R0002?
The digital and analog outputs associated with ABB SDCS-CON-H01 3ADT220166R0002 remain frozen when the internal watchdog has tripped.