Features:
- 1.5 kW and 4.1 A output in the narrow R1 frame
- Connected EMC filter with 50 Hz default frequency
- Built-in brake chopper and standard Safe Torque Off interface
ACS355-03E-04A1-4 is the compact 1.5 kW E-construction entry in this 380-480 V ACS355 group.
Its small R1 footprint supports machine panels where speed control, application macros, programmable signals, and a documented stopping strategy must share limited cabinet space.
A useful engineering record links the motor and load to EMC earthing, resistor duty, STO wiring, airflow, macro selection, and the first loaded run.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS355-03E-04A1-4 ACS355 Machinery Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS355-03E-04A1-4 ACS355 Machinery Drive Specs
General
- ManufacturerABB
- ModelACS355-03E-04A1-4
- ConditionNew Original ready stock
- Product FamilyABB ACS355 Machinery Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
R1 installation priorities
- Mounting space: Keep the documented cooling clearances and terminal working space available.
- Cable zones: Separate supply, motor, brake-resistor, and low-level control conductors.
- EMC earthing: Apply the ABB procedure if the connected filter is unsuitable for the supply system.
- Service access: Leave the cover, panel connector, fan path, and isolation points accessible.
Application-macro planning
- Control owner: Decide whether the panel, terminals, or serial interface commands the machine.
- Signal map: Assign references, enables, direction, resets, and status outputs before wiring.
- Limits: Set speed, torque, acceleration, and deceleration limits from the approved machine study.
- Backup: Archive the accepted parameter set after the loaded test.
Small-machine duty review
- Nameplate: Use the actual motor current and voltage rather than nominal power alone.
- Low-speed torque: Check cooling and torque needs through the complete working range.
- Stopping energy: Calculate deceleration energy before selecting an external resistor.
- STO circuit: Validate the Safe Torque Off interface within the machine safety design.