ABB ACS510-01-046A-4 is a 22 kW, 46 A, 380-480 V IP21 general purpose wall-mounted drive in frame R3.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS510-01-046A-4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS510-01-046A-4

  • Manufacturer:
    ABB
  • Part Number:
    ACS510-01-046A-4
  • Product Family:
    ABB Drives
  • Product Type:
    ACS510 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3ABD00021615-D
  • Input Voltage:
    380 ... 480 V AC
  • Input Frequency:
    47.5 ... 63 Hz
  • Number of Phases:
    3-phase
  • Normal Output Current:
    46 A
  • Normal Output Power:
    22 kW
  • Apparent Power Output:
    32 kV·A
  • Frame Size:
    R3
  • Degree of Protection:
    IP21
  • Enclosure Type:
    NEMA Type 1
  • Mounting:
    Wall-mounted
  • Efficiency Level:
    IE2
  • Standby Loss:
    15 W
  • Temperature Rating:
    40 °C
  • Built-in Communication:
    Modbus
  • Weight:
    18 kg
  • Estimated shipping dimensions:
    28.4 x 38.4 x 67.5 cm
  • Tariff Code:
    85044099
  • Country of origin:
    China
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Power Wiring Process Control Commissioning

Features:

  • 22 kW normal-use output rated 46 A
  • R3 wall-mounted enclosure with IP21 protection
  • Integrated Modbus and configurable control terminals
ACS510-01-046A-4 is the 46 A configuration at the upper end of the ACS510 R3 group.

Its power and control functions can serve coordinated variable-speed duties when feeder protection, motor behavior, process references, interlocks, and communication ownership are engineered together.

Successful installation depends on cable and terminal planning, protection and isolation, enclosure airflow, braking and stop requirements, signal testing, motor setup, loaded observations, and controlled documentation.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS510-01-046A-4 ACS510 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS510-01-046A-4 ACS510 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS510-01-046A-4
  • ConditionNew Original ready stock
  • Product FamilyABB ACS510 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

22 kW feeder and termination review

  • Protection: Coordinate fuse and isolation selection with the actual short-circuit level.
  • Conductors: Check material, cross-section, temperature rating, voltage drop, and terminal range.
  • Terminations: Control lug preparation, bend radius, support, torque, and phase spacing.
  • Earthing: Complete PE and shield connections before insulation and continuity tests.

Command and reference ownership

  • References: Validate analog or network scaling and operating limits.
  • Interlocks: Prove enable, stop, permissive, and external protection signals.
  • Fallback: Specify the response to reference loss, network timeout, and controller restart.
  • Local mode: Control when panel operation is permitted and how authority transfers.

Loaded acceptance sequence

  • Pre-power: Inspect identifiers, wiring, insulation, PE, clearances, and cooling.
  • Motor setup: Enter nameplate data and verify direction under safe conditions.
  • Process test: Observe current, speed, temperature, and interlocks across the required range.
  • Handover: Approve parameters, drawings, tests, backups, and maintenance responsibilities.
Description
ACS510-01-046A-4 is the 22 kW, 46 A normal-use configuration in ABB's ACS510 R3 mechanical platform for 380-480 V three-phase systems.

ACS510-01-046A-4 supports controlled acceleration, speed regulation, process references, relay status, local operation, and Modbus-based supervision in engineered motor applications.

ACS510-01-046A-4 needs a complete power-wiring and commissioning plan covering fault level, fuses and conductors, motor-cable length, terminal access, R3 airflow, motor data, process interlocks, braking equipment, network commands, and loaded acceptance.
Alternative Names
ACS510 01 046A 4 ACS51001046A4 3ABD00021615-D ABB ACS510-01-046A-4 ABB 3ABD00021615-D ACS510 22 kW drive 46 A R3 wall-mounted drive ABB general purpose drive 22 kW
Technical notes
Before installing ACS510-01-046A-4, verify the 46 A motor duty and coordinate the published 50 A IEC fuse basis with the site short-circuit study. The 22 kW R3 layout must reserve conductor-bending and terminal space, supply the documented cooling airflow, separate control wiring, define external braking hardware, prove Modbus timeout behavior, and archive startup results.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should power cables be selected for the 46 A ACS510-01-046A-4 output?
For ACS510-01-046A-4, use the 46 A continuous duty and 50 A IEC fuse basis with conductor material, installation method, ambient temperature, grouping, voltage drop, short-circuit withstand, PE sizing, terminal range, and cable length. This prevents selection from the 22 kW value alone.
What must be checked before the first loaded ACS510-01-046A-4 run?
Verify motor data and direction, mechanical readiness, R3 cooling, 50 A protection, 46 A current limits, ramps, process permissives, reference scaling, Modbus commands, and stop behavior. Observe the first 22 kW load safely so wiring, torque demand, and control ownership are confirmed together.
Why can ACS510-01-046A-4 trip on DC overvoltage while stopping?
ACS510-01-046A-4 requires external braking scope to be assessed for regenerative energy, deceleration time, overhauling torque, supply voltage, DC control settings, resistor thermal capacity, and process sequence. Do not assume the internal-chopper arrangement used by smaller frames applies to this R3 configuration.
Can ACS510-01-046A-4 reuse another drive’s network configuration?
Reuse is acceptable only after checking address, baud rate, parity, control and status words, scaling, timeout, local or remote logic, firmware, controller mapping, and the 46 A motor settings. A copied network map must not overwrite this rating’s protection or loaded-test baseline.
How should loose-terminal risk be controlled in the ACS510-01-046A-4 circuit?
Follow ABB conductor-preparation and torque instructions for ACS510-01-046A-4, use approved lugs and tools, support the R3 cables, verify phase spacing, perform visual and pull checks, record torque where required, and re-inspect under the maintenance plan. The higher-current termination deserves its own evidence.
Which procurement details distinguish ACS510-01-046A-4?
Confirm ACS510-01-046A-4, Product ID 3ABD00021615-D, the 22 kW and 46 A duty, R3 layout, 50 A fuse basis, 667 W heat load, motor and cable design, braking and communication scope, quantity, destination, inspection, and required delivery date.