Features:
- 45 kW normal-use rating with 88 A output
- R4 IP21 wall-mounted mechanical construction
- Documented 1, 4, and 8 kHz switching-frequency availability
ACS510-01-088A-4 is the 88 A, 45 kW endpoint of the R4 ratings in the official ACS510 table.
Its higher current and heat load increase the importance of conductor, protection, cooling, motor-cable, switching-frequency, and service-access decisions.
Before procurement, complete the motor and feeder study, R4 layout and airflow plan, braking and stop assessment, EMC and earthing design, network and interlock tests, handling plan, and recovery documentation.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS510-01-088A-4 ACS510 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS510-01-088A-4 ACS510 General Purpose Wall-Mounted Drive Specs
General
- ManufacturerABB
- ModelACS510-01-088A-4
- ConditionNew Original ready stock
- Product FamilyABB ACS510 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Motor and drive frequency review
- Availability: Keep switching-frequency selection within the published limits for this rating.
- Derating: Apply current reduction when ABB conditions require it.
- Motor effects: Review audible noise, losses, insulation stress, and motor temperature.
- Cable system: Consider cable length, shielding, capacitance, and output filtering requirements.
88 A power-circuit preparation
- Protection: Coordinate the documented fuse basis with the site fault-current study.
- Conductors: Verify thermal rating, installation, voltage drop, bend radius, and terminals.
- PE and shields: Complete protective-earth and EMC terminations using the approved method.
- Inspection: Record lug preparation, torque, support, phase spacing, and final checks.
Controlled return-to-service
- Capture: Preserve fault code, time, operating values, and process context.
- Isolation: Use the approved safe-isolation and stored-energy procedure.
- Diagnosis: Check supply, motor, cable, cooling, load, controls, and recent changes.
- Acceptance: Restore service only after controlled tests and updated records.