Features:
- 18.5 kW normal-use configuration with 38 A output
- R3 IP21 format for wall-mounted installation
- Light-duty and heavy-duty ratings documented by ABB
ACS580-01-039A-4 3AXD50000038962 is the 18.5 kW member of the 400 V wall-mounted drive range.
Its control resources can combine local operation, analog references, digital permissives, and serial supervision in a single motor-control package.
An engineering review should resolve duty classification, available short-circuit protection, enclosure airflow, control-voltage interfaces, communication options, and the commissioning method before the order is released.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-039A-4 3AXD50000038962 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-039A-4 3AXD50000038962 ACS580 General Purpose Wall-Mounted Drive Specs
General
- ManufacturerABB
- ModelACS580-01-039A-4 3AXD50000038962
- ConditionNew Original ready stock
- Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Normal and overload duty selection
- Normal use: Apply the 38 A rating only when the process does not require a higher overload class.
- Light overload: Check the 36.1 A light-duty rating against the complete cycle.
- Heavy duty: Use the published 31.6 A/15 kW rating when the process needs the heavier overload profile.
- Derating: Review ambient temperature, altitude, enclosure, and switching-frequency effects.
R3 cabinet integration
- Clearance: Reserve the installation spaces required by the R3 hardware instructions.
- Air path: Prevent recirculation of exhaust air and keep ventilation openings clear.
- Heat load: Include the drive losses and adjacent equipment in the enclosure calculation.
- Access: Leave practical space for terminals, control wiring, panel operation, and service.
Signals and network coordination
- Commands: Document start, stop, direction, enable, and reset sources.
- References: Define local, analog, serial, and fallback speed-reference behavior.
- Feedback: Map status, alarms, and process signals before wiring the I/O.
- Fieldbus: Specify the adapter and network engineering scope when Modbus RTU is not used.