Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB documentation, duty checks, and 3 kW drive sourcing.

ACS580-01-07A3-4 3AXD50000038951

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS580-01-07A3-4 3AXD50000038951 is a 400 V ACS580-01 IP21 wall-mounted drive rated 7.2 A and 3.0 kW for general-purpose motor control.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS580-01-07A3-4 3AXD50000038951
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS580-01-07A3-4 3AXD50000038951

  • Manufacturer:
    ABB
  • Part Number:
    ACS580-01-07A3-4 3AXD50000038951
  • Product Family:
    ABB Drives
  • Product Type:
    ACS580 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3AXD50000038951
  • Voltage Class:
    400 V
  • Nominal Output Current:
    7.2 A
  • Nominal Motor Power:
    3.0 kW
  • Maximum Current:
    10.1 A
  • Heavy-Duty Rating:
    5.6 A / 2.2 kW
  • Frame Size:
    R1
  • Maximum Losses:
    127 W
  • Protection:
    IP21 / UL Type 1
  • Control Panel:
    ACS-AP-S assistant control panel
  • Safety Function:
    Safe Torque Off integrated
  • EMC and Braking:
    Internal EMC C2 filter; integrated braking chopper
  • Weight:
    4.6 kg
  • Estimated shipping dimensions:
    12.5x37.3x22.3cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Commissioning EMC & Grounding Option Planning

Features:

  • General-purpose motor control: The 3.0 kW/7.2 A nominal-use rating covers common variable-torque and constant-torque applications.
  • Built-in engineering functions: Safe Torque Off, EMC filtering, an assistant panel, coated boards, and a braking chopper reduce external hardware.
  • Application flexibility: Motor macros, energy functions, optional fieldbus adapters, and configurable I/O support plant integration.
ACS580-01-07A3-4 3AXD50000038951 balances motor-control capability with a compact R1 wall-mounted package for 400 V industrial systems.

The assistant panel supports commissioning and diagnostics, while the base hardware includes STO, EMC filtering, and a braking chopper; protocol adapters remain project-specific options.

Select the drive from measured motor current and duty, then validate the supply system, protection, cable, ventilation, EMC, control wiring, fieldbus, parameters, and fault-response plan.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-07A3-4 3AXD50000038951 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-07A3-4 3AXD50000038951 ACS580 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS580-01-07A3-4 3AXD50000038951
  • ConditionNew Original ready stock
  • Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Startup and motor matching

  • Motor data: Enter the verified nameplate voltage, current, frequency, speed, and power.
  • Duty check: Use actual load torque, overload duration, ambient conditions, and switching frequency.
  • Direction test: Prove motor rotation and process interlocks before coupling the full load.
  • Record: Archive parameters, option codes, firmware, fault history, and acceptance results.

Supply-system compatibility

  • TN-S system: The internal EMC filter is intended for a symmetrically grounded TN-S supply.
  • Other systems: Follow ABB instructions before connecting to IT, corner-grounded delta, midpoint-grounded delta, or TT systems.
  • Protective earth: Use the required PE conductors, shield terminations, and cable routing.
  • Motor cable: Select cable construction and length against EMC and drive hardware limits.

Controls and communication scope

  • Fieldbus: Select the ABB adapter that matches the plant protocol and engineering tool.
  • I/O: Map every command, reference, interlock, and feedback signal before wiring.
  • Safety: Integrate STO into the machine safety function; it is not a general isolation device.
  • Braking: Verify whether the integrated chopper, an external resistor, and thermal protection are required.
Description
ACS580-01-07A3-4 3AXD50000038951 is the 3.0 kW, 7.2 A nominal-use configuration in ABB’s ACS580-01 general-purpose drive family, designed to control standard induction and permanent-magnet motors in pumps, fans, conveyors, mixers, and similar industrial loads.

ACS580-01-07A3-4 3AXD50000038951 uses frame R1 with a maximum current of 10.1 A, heavy-duty rating of 5.6 A/2.2 kW, an assistant control panel, internal EMC filtering, Safe Torque Off, coated boards, and an integrated braking chopper.

ACS580-01-07A3-4 3AXD50000038951 simplifies cabinet and machine integration, but reliable operation still depends on correct motor sizing, overload duty, cable and fuse selection, earthing system, EMC configuration, ventilation, fieldbus options, and a validated startup record.
Alternative Names
ACS580-01-07A3-4 ACS580 01 07A3 4 ACS5800107A34 3AXD50000038951 ABB ACS580-01-07A3-4
Technical notes
ACS580-01-07A3-4 3AXD50000038951 is a R1, 400 V drive rated 7.2 A/3.0 kW nominal. Before energizing, verify motor nameplate data, overload duty, protective earth, cable and fuse sizing, STO wiring, and the supply earthing system. The internal EMC filter is intended for symmetrical TN-S networks and may require disconnection on IT, corner-grounded delta, midpoint-grounded delta, or TT systems.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should ACS580-01-07A3-4 3AXD50000038951 be selected for a 3.0 kW motor with repeated high-load cycles?
ABB lists 7.2 A/3.0 kW for nominal use but 5.6 A/2.2 kW for heavy duty. Verify the actual torque cycle instead of selecting from motor power alone.
Why does ACS580-01-07A3-4 3AXD50000038951 share a 10 A gG fuse class with the smaller 05A7 rating?
ABB specifies 10 A gG protection with 80 A minimum installation short-circuit current for this 7.2 A input rating. Use the complete coordination data, not drive size alone.
What cabinet heat check is required for the 127 W maximum loss of ACS580-01-07A3-4 3AXD50000038951?
Calculate enclosure temperature rise using the documented 127 W loss, R1 airflow, installation spacing, neighboring losses, ambient temperature, and the cabinet cooling method.
Can ACS580-01-07A3-4 3AXD50000038951 be exchanged with ACS580-01-09A5-4 because both use frame R1?
No. The 09A5 configuration raises nominal current to 9.4 A, motor power to 4.0 kW, maximum current to 13.0 A, and gG fuse selection to 16 A.
What does the 10.1 A maximum current mean during ACS580-01-07A3-4 3AXD50000038951 acceleration checks?
It does not replace the 7.2 A nominal or 5.6 A heavy-duty ratings. Review motor data, acceleration time, load inertia, current limits, supply quality, and recorded fault context.
Which details distinguish a useful quotation request for ACS580-01-07A3-4 3AXD50000038951?
State the 7.2 A/3.0 kW operating point, expected overload, motor data, 10 A gG or approved semiconductor-fuse method, R1 installation, protocol option, quantity, and destination.