Features:
- 45 kW and 88 A normal-use rating
- 83 A light-duty and 72 A heavy-duty operating points
- R5 IP21 wall-mounted drive configuration
ACS580-01-088A-4 3AUA0000080502 is the exact 45 kW drive configuration in the R5 enclosure.
Its duty ratings allow engineers to select the unit against the real load cycle rather than treating the normal-use current as an unconditional continuous choice for every process.
Confirm the full nameplate identity, motor data, overload profile, feeder and motor cable, R5 mounting plan, heat removal, I/O and network scope, safety design, and commissioning records before use.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-088A-4 3AUA0000080502 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-088A-4 3AUA0000080502 ACS580 General Purpose Wall-Mounted Drive Specs
General
- ManufacturerABB
- ModelACS580-01-088A-4 3AUA0000080502
- ConditionNew Original ready stock
- Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Exact 088A configuration control
- Type designation: Match ACS580-01-088A-4 character by character on the rating label.
- Product ID: Use 3AUA0000080502 to distinguish the requested commercial configuration.
- Option codes: Record every suffix because options can change enclosure, controls, and installation scope.
- Nameplate photos: Retain clear front and side label images with the purchase and maintenance records.
R5 feeder and cable review
- Protection: Coordinate the documented fuse basis with the actual short-circuit study.
- Terminations: Check conductor size, lug or clamp requirements, bending space, and tightening instructions.
- Motor cable: Verify shield, PE, insulation, length, and routing against the installation manual.
- Cooling: Keep the R5 inlet and outlet path unobstructed and serviceable.
Evidence-led troubleshooting
- Capture: Record fault code, timestamp, current, voltage, speed, and process state before reset.
- Power quality: Review supply phase balance, interruptions, and DC-link behavior.
- Load: Inspect mechanical binding, torque demand, ramps, and motor condition.
- History: Compare recurring events with parameter, wiring, and process changes.