Features:
- 55 kW normal-use output rated 106 A
- 100 A light-duty and 87 A heavy-duty ratings
- R5 IP21 housing for wall-mounted projects
ACS580-01-106A-4 3AUA0000080503 is the 55 kW R5 configuration in ABB’s ACS580-01 400 V range.
The control platform can exchange commands and feedback through hardwired I/O or approved communication options while coordinating motor speed and process interlocks.
Project release should follow feeder coordination, conductor and termination design, cooling and access checks, duty and braking calculations, signal and network ownership, safety testing, and recovery planning.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-106A-4 3AUA0000080503 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-106A-4 3AUA0000080503 ACS580 General Purpose Wall-Mounted Drive Specs
General
- ManufacturerABB
- ModelACS580-01-106A-4 3AUA0000080503
- ConditionNew Original ready stock
- Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
R5 electrical and mechanical layout
- Feeder: Coordinate the protective device, isolation, and conductor system with the site study.
- Cable space: Reserve the R5 bending and termination space before fabrication.
- Ventilation: Calculate enclosure heat removal using the actual operating duty.
- Access: Keep control, power, fan, and panel service points safely reachable.
Control ownership and network scope
- Base protocol: Use Modbus RTU only after address, baud rate, parity, and ownership are documented.
- Adapter option: Select the approved ABB module for other plant protocols.
- Control source: Define how local, hardwired, and network commands transfer without ambiguity.
- Fallback: Specify behavior for network loss, invalid references, and controller restart.
R5 evidence and service planning
- Inspection: Set intervals for airflow, fan, terminals, cables, and contamination checks.
- Backups: Store the accepted parameters and communication configuration under revision control.
- Fault data: Preserve event context before clearing or replacing hardware.
- Replacement: Compare type, Product ID, option codes, firmware, terminals, and drawings before exchange.