ABB ACS880-01-017A-3 3AUA0000107991 is a 7.5 kW, 17 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R2.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-017A-3 3AUA0000107991
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-017A-3 3AUA0000107991

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-017A-3 3AUA0000107991
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000107991
  • Nominal Motor Power:
    7.5 kW
  • Normal Output Current:
    17 A
  • Light-Duty Rating:
    16 A / 7.5 kW
  • Heavy-Duty Rating:
    12.6 A / 5.5 kW
  • Maximum Output Current:
    21 A
  • Frame Size:
    R2
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    12 kVA
  • Power Consumption:
    235 W
  • Sound Pressure:
    59 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    8.4 kg
  • Estimated shipping dimensions:
    57.4x30.4x25.6cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Motor Matching Installation Startup

Features:

  • 7.5 kW and 17 A normal-use rating at 400 V
  • R2 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-017A-3 3AUA0000107991 is the 7.5 kW, 17 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-017A-3 3AUA0000107991 uses the R2 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-017A-3 3AUA0000107991 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-017A-3 3AUA0000107991 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-017A-3 3AUA0000107991 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-017A-3 3AUA0000107991
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

7.5 kW application review

  • Nameplate current: Check actual motor current against the 17 A normal-use and 12.6 A heavy-duty ratings.
  • Load duty: Document torque characteristic, overload duration, starting demand, inertia, ramps, and braking behavior.
  • Motor system: Confirm motor insulation, cable length, switching conditions, speed range, and required filtering.
  • Derating: Apply the official altitude, temperature, enclosure, and switching-frequency instructions where relevant.

R2 mounting and electrical checks

  • Mounting: Use the approved R2 orientation, fasteners, clearances, and service-access arrangement.
  • Protection: Coordinate isolation, fuses, conductors, prospective fault current, and local electrical requirements.
  • Earthing: Complete PE, cable-shield, EMC, and supply-system checks before power-up.
  • Control wiring: Separate power and control routes and verify I/O, Safe Torque Off, and option-module connections.

R2 commissioning sequence

  • Motor data: Enter and verify the complete nameplate values before the approved identification routine.
  • Direction: Prove rotation with the process uncoupled or otherwise placed in a safe test condition.
  • Interlocks: Test enable, stop, Safe Torque Off, process permissives, references, and network-loss behavior.
  • Records: Archive the accepted parameters, firmware, option codes, readings, fault history, and recovery plan.
Description
ACS880-01-017A-3 3AUA0000107991 is the 7.5 kW, 17 A normal-use configuration in ABB’s ACS880-01 industrial drive family, using an IP21 wall-mounted R2 enclosure for 380–415 V three-phase systems.

ACS880-01-017A-3 3AUA0000107991 combines Direct Torque Control with the documented control unit, two analog inputs, two analog outputs, and six digital inputs plus two digital outputs for coordinated motor and process control.

ACS880-01-017A-3 3AUA0000107991 should be selected only after the motor nameplate current, overload profile, supply earthing, protective devices, cable design, braking demand, enclosure ventilation, and required communication options have been confirmed.
Alternative Names
ACS880 01 017A 3 ACS88001017A3 3AUA0000107991 ABB ACS880-01-017A-3 ABB ACS880-01-017A-3 3AUA0000107991 ACS880 7.5 kW R2 wall mounted drive ACS880-01-017A-3 17 A industrial drive
Technical notes
Before energizing ACS880-01-017A-3 3AUA0000107991, verify the 380–415 V three-phase supply, the motor nameplate current, and whether the 17 A normal-use or 12.6 A heavy-duty point governs selection. The R2 IP21 installation also requires coordinated protection, earthing, motor cabling, ventilation, Safe Torque Off wiring, and any required communication option.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When does the 12.6 A heavy-duty point, rather than the 17 A normal-use rating, govern selection of ACS880-01-017A-3 3AUA0000107991?
Use the motor nameplate current, continuous torque, overload magnitude, and repetition rate. A heavy-duty application must be checked against 12.6 A and 5.5 kW; the 17 A and 7.5 kW normal-use point cannot be carried over automatically.
If ACS880-01-017A-3 3AUA0000107991 reaches its 21 A maximum output before a high-inertia load gains speed, which evidence should be reviewed first?
Read the time-stamped fault record, confirm the entered motor data, and check for mechanical binding. Then compare load inertia, requested ramp, current limits, supply condition, and actual duty with the documented continuous and heavy-duty ratings.
A compact R2 retrofit is planned: what must be surveyed before ACS880-01-017A-3 3AUA0000107991 is released for installation?
Record mounting orientation, required clearances, cable entry, terminal access, protective devices, PE and shield arrangement, control wiring, and installed options. An existing R2 label alone does not establish mechanical or electrical interchangeability.
Which hardwired control functions can be allocated around ACS880-01-017A-3 3AUA0000107991 before a communication option is selected?
Start from the documented two analog inputs, two analog outputs, six digital inputs, and two digital outputs. Assign references, feedback, enables, interlocks, and status signals, then document scaling, fail states, and control ownership.
How should the built-in Safe Torque Off function be proved during commissioning of ACS880-01-017A-3 3AUA0000107991?
Trace the installed safety wiring against the approved ABB and project diagrams, verify the external safety logic, perform the authorized functional test, and retain the result. Safe Torque Off must not be treated as service isolation.
If ACS880-01-017A-3 3AUA0000107991 will serve a 5.5 kW heavy-duty load, which documents belong in the purchase package?
Include the complete nameplate, motor current and torque data, overload profile, supply and earthing details, enclosure conditions, option requirements, safety and braking scope, quantity, destination, and the approved 12.6 A duty basis.