Features:
- 15 kW and 32 A normal-use rating at 400 V
- R3 wall-mounted enclosure with IP21 protection
- Direct Torque Control with built-in Safe Torque Off
ACS880-01-032A-3 3AUA0000107993 is the 15 kW, 32 A normal-use configuration in ABB’s ACS880-01 industrial drive range.
ACS880-01-032A-3 3AUA0000107993 uses the R3 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.
ACS880-01-032A-3 3AUA0000107993 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.
Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-032A-3 3AUA0000107993 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-032A-3 3AUA0000107993 ACS880 Industrial Wall-Mounted Single Drive Specs
General
- ManufacturerABB
- ModelACS880-01-032A-3 3AUA0000107993
- ConditionNew Original ready stock
- Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
15 kW application review
- Nameplate current: Check actual motor current against the 32 A normal-use and 25 A heavy-duty ratings.
- Load duty: Document torque characteristic, overload duration, starting demand, inertia, ramps, and braking behavior.
- Motor system: Confirm motor insulation, cable length, switching conditions, speed range, and required filtering.
- Derating: Apply the official altitude, temperature, enclosure, and switching-frequency instructions where relevant.
R3 mounting and electrical checks
- Mounting: Use the approved R3 orientation, fasteners, clearances, and service-access arrangement.
- Protection: Coordinate isolation, fuses, conductors, prospective fault current, and local electrical requirements.
- Earthing: Complete PE, cable-shield, EMC, and supply-system checks before power-up.
- Control wiring: Separate power and control routes and verify I/O, Safe Torque Off, and option-module connections.
R3 commissioning sequence
- Motor data: Enter and verify the complete nameplate values before the approved identification routine.
- Direction: Prove rotation with the process uncoupled or otherwise placed in a safe test condition.
- Interlocks: Test enable, stop, Safe Torque Off, process permissives, references, and network-loss behavior.
- Records: Archive the accepted parameters, firmware, option codes, readings, fault history, and recovery plan.