ACS880-01-061A-3 3AUA0000108021

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS880-01-061A-3 3AUA0000108021 is a 30 kW, 61 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R4.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-061A-3 3AUA0000108021
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-061A-3 3AUA0000108021

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-061A-3 3AUA0000108021
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000108021
  • Nominal Motor Power:
    30 kW
  • Normal Output Current:
    61 A
  • Light-Duty Rating:
    58 A / 30 kW
  • Heavy-Duty Rating:
    45 A / 22 kW
  • Maximum Output Current:
    76 A
  • Frame Size:
    R4
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    42 kVA
  • Power Consumption:
    818 W
  • Sound Pressure:
    64 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    18.6 kg
  • Estimated shipping dimensions:
    69.1x32.9x29cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Motor Matching Installation Startup

Features:

  • 30 kW and 61 A normal-use rating at 400 V
  • R4 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-061A-3 3AUA0000108021 is the 30 kW, 61 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-061A-3 3AUA0000108021 uses the R4 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-061A-3 3AUA0000108021 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-061A-3 3AUA0000108021 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-061A-3 3AUA0000108021 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-061A-3 3AUA0000108021
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

30 kW application review

  • Nameplate current: Check actual motor current against the 61 A normal-use and 45 A heavy-duty ratings.
  • Load duty: Document torque characteristic, overload duration, starting demand, inertia, ramps, and braking behavior.
  • Motor system: Confirm motor insulation, cable length, switching conditions, speed range, and required filtering.
  • Derating: Apply the official altitude, temperature, enclosure, and switching-frequency instructions where relevant.

R4 mounting and electrical checks

  • Mounting: Use the approved R4 orientation, fasteners, clearances, and service-access arrangement.
  • Protection: Coordinate isolation, fuses, conductors, prospective fault current, and local electrical requirements.
  • Earthing: Complete PE, cable-shield, EMC, and supply-system checks before power-up.
  • Control wiring: Separate power and control routes and verify I/O, Safe Torque Off, and option-module connections.

R4 commissioning sequence

  • Motor data: Enter and verify the complete nameplate values before the approved identification routine.
  • Direction: Prove rotation with the process uncoupled or otherwise placed in a safe test condition.
  • Interlocks: Test enable, stop, Safe Torque Off, process permissives, references, and network-loss behavior.
  • Records: Archive the accepted parameters, firmware, option codes, readings, fault history, and recovery plan.
Description
ACS880-01-061A-3 3AUA0000108021 is the 30 kW, 61 A normal-use member of ABB’s ACS880-01 range built in the wall-mounted R4 frame, with IP21 protection and a 380–415 V three-phase supply specification.

ACS880-01-061A-3 3AUA0000108021 applies Direct Torque Control to industrial motor duties and connects the drive’s operating references, interlocks, analog signals, digital signals, and optional communications to the surrounding automation architecture.

ACS880-01-061A-3 3AUA0000108021 requires an engineering review of the 58 A light-duty and 45 A heavy-duty points, feeder fault level, protection and isolation, conductor and PE sizing, cable-entry space, heat removal, braking energy, safety wiring, and commissioning records.
Alternative Names
ACS880 01 061A 3 ACS88001061A3 3AUA0000108021 ABB ACS880-01-061A-3 ABB ACS880-01-061A-3 3AUA0000108021 ACS880 30 kW R4 wall mounted drive ACS880-01-061A-3 61 A industrial drive
Technical notes
Before releasing ACS880-01-061A-3 3AUA0000108021, check whether the 61 A normal-use or 45 A heavy-duty rating controls the application and confirm the motor data. Complete the R4 feeder, fuse, cable, earthing, airflow, braking, Safe Torque Off, I/O, option-code, and startup design for the documented 380–415 V three-phase supply.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does sharing an R4 frame with a lower-current drive not make ACS880-01-061A-3 3AUA0000108021 electrically interchangeable?
This configuration carries a 61 A normal-use and 45 A heavy-duty basis. Recheck feeder protection, conductors, terminals, heat rejection, motor and braking duty, options, parameters, and safety wiring even when the mechanical frame designation matches.
What cooling evidence is required when the documented 818 W loss of ACS880-01-061A-3 3AUA0000108021 is placed inside a control enclosure?
Calculate the enclosure heat balance using site ambient, adjacent losses, ventilation performance, inlet condition, and ABB derating rules. Confirm that the R4 airflow path, clearances, terminals, and option access remain unobstructed.
During a loaded start, how should a 76 A maximum-output event from ACS880-01-061A-3 3AUA0000108021 be interpreted?
Do not use 76 A as a continuous rating. Correlate the event with speed, torque, motor data, ramp profile, mechanical load, cable and supply condition, and the selected 61 A normal or 45 A heavy-duty operating point.
For a 22 kW high-overload motor, which checks decide whether ACS880-01-061A-3 3AUA0000108021 is correctly sized?
Compare the full torque-time profile, actual motor current, start frequency, acceleration demand, overload duration, and cooling conditions with the documented 45 A heavy-duty point. Selection should not rely on nominal motor power alone.
When an optional fieldbus is added to ACS880-01-061A-3 3AUA0000108021, which control responsibilities must remain explicit?
Document ownership of run and stop commands, speed or torque references, hardwired interlocks, Safe Torque Off, feedback, fault reset, network-loss behavior, and local control. Confirm the selected option and firmware from official records.
Which project data should accompany a purchase request for the 30 kW configuration ACS880-01-061A-3 3AUA0000108021?
Send the complete Product ID, motor nameplate, load and overload profile, supply and earthing, protection and cable study, enclosure cooling, braking, I/O and communication scope, safety requirements, quantity, and destination.