Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB documentation, duty review, and installation planning.

ACS880-01-169A-3 3AUA0000108027

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS880-01-169A-3 3AUA0000108027 is a 90 kW, 169 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R7.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-169A-3 3AUA0000108027
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-169A-3 3AUA0000108027

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-169A-3 3AUA0000108027
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000108027
  • Nominal Motor Power:
    90 kW
  • Normal Output Current:
    169 A
  • Light-Duty Rating:
    161 A / 90 kW
  • Heavy-Duty Rating:
    145 A / 75 kW
  • Maximum Output Current:
    247 A
  • Frame Size:
    R7
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    117 kVA
  • Power Consumption:
    2042 W
  • Sound Pressure:
    67 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    53 kg
  • Estimated shipping dimensions:
    99.2x59.8x40cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Project Planning Motor & Braking Commissioning

Features:

  • 90 kW and 169 A normal-use rating at 400 V
  • R7 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-169A-3 3AUA0000108027 is the 90 kW, 169 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-169A-3 3AUA0000108027 uses the R7 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-169A-3 3AUA0000108027 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-169A-3 3AUA0000108027 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-169A-3 3AUA0000108027 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-169A-3 3AUA0000108027
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

R7 delivery and installation scope

  • Handling: Approve the delivery route, lifting method, mounting support, and final orientation for the R7 drive.
  • Electrical design: Coordinate the 169 A normal-use rating with the site fault-current, isolation, protection, and conductor studies.
  • Thermal plan: Provide the documented airflow and keep control, fan, power-terminal, and option-module access clear.
  • Responsibilities: Assign ownership for signals, networks, safety validation, commissioning, records, and maintenance.

90 kW duty review

  • Motor match: Compare nameplate current and load torque with the 169 A normal-use and 145 A heavy-duty points.
  • Acceleration: Calculate starting torque, inertia, ramp time, peak current, and process limits before startup.
  • Braking: Calculate regenerative energy, stopping time, repetition, chopper scope, resistor duty, and thermal protection.
  • Cabling: Verify motor insulation, cable construction, length, routing, shield termination, and bearing-current measures where required.

R7 acceptance controls

  • Pre-power checks: Verify identifiers, options, mounting, PE continuity, insulation, terminations, airflow, and Safe Torque Off wiring.
  • Motor data: Enter the complete motor nameplate values and follow the approved identification procedure.
  • Functional test: Prove direction, commands, references, interlocks, network loss behavior, limits, and loaded response.
  • Handover: Archive firmware, option codes, parameters, test results, fault baseline, drawings, and the recovery procedure.
Description
ACS880-01-169A-3 3AUA0000108027 is the 90 kW, 169 A normal-use type in the ACS880-01 industrial drive family, supplied in ABB’s R7 wall-mounted frame for 380–415 V three-phase systems with IP21 protection.

ACS880-01-169A-3 3AUA0000108027 applies Direct Torque Control while linking the high-power motor feeder to documented control I/O, Safe Torque Off, operating references, plant feedback, and selected communications within the engineered automation system.

ACS880-01-169A-3 3AUA0000108027 requires project-level planning for the 161 A light-duty and 145 A heavy-duty ratings, delivery route and lifting, R7 mounting, fault-current coordination, conductor bending and termination, heat removal, braking energy, network ownership, safety validation, and service strategy.
Alternative Names
ACS880 01 169A 3 ACS88001169A3 3AUA0000108027 ABB ACS880-01-169A-3 ABB ACS880-01-169A-3 3AUA0000108027 ACS880 90 kW R7 wall mounted drive ACS880-01-169A-3 169 A industrial drive
Technical notes
Confirm the delivery route, lifting equipment, R7 mounting support, and protected staging area before ACS880-01-169A-3 3AUA0000108027 arrives. The 90 kW, 169 A power design also needs a verified 380–415 V feeder study, high-current cable and PE terminations, cooling, braking duty, Safe Torque Off wiring, communication scope, commissioning controls, and maintenance access.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should a 90 kW motor duty be tested against the 169 A and 145 A ratings of ACS880-01-169A-3 3AUA0000108027?
Compare the motor nameplate and full torque-time profile with the normal-use and heavy-duty columns, including starts, peaks, duration, and recovery. Use the 145 A and 75 kW point when heavy-duty service governs.
What does the documented 2042 W loss of ACS880-01-169A-3 3AUA0000108027 require from the room or enclosure heat study?
Include the loss with ambient temperature, neighboring equipment, ventilation capacity, airflow direction, recirculation risk, and ABB derating rules. The R7 installation must retain the specified cooling and service clearances.
If ACS880-01-169A-3 3AUA0000108027 reaches 247 A while a loaded machine accelerates, which traces should be reviewed before settings are changed?
Examine output current, speed, torque reference, entered motor data, ramp command, inertia, mechanical condition, supply quality, event duration, and fault history. Compare the event with the approved 169 A or 145 A duty.
For an R7 installation, which delivery constraints must be closed before ACS880-01-169A-3 3AUA0000108027 arrives?
Confirm the transport route, lifting equipment, protected staging, mounting support, final orientation, clearances, cable approach, terminal access, and maintenance space using the approved ABB installation information.
What must the high-current termination design demonstrate for ACS880-01-169A-3 3AUA0000108027?
Verify conductor and PE sizing, approved lugs, terminal capacity, bending radius and space, entry direction, shielding, separation, protective device coordination, tightening requirements, and safe installation and inspection access.
When network control is used, how should Safe Torque Off and command ownership be separated for ACS880-01-169A-3 3AUA0000108027?
Document which functions remain hardwired, who owns run, stop, reference, interlocks, reset, and feedback, and how network loss is handled. Validate the safety circuit independently and archive the accepted option and firmware records.