Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB documentation, duty review, and installation planning.

ACS880-01-206A-3 3AUA0000108028

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS880-01-206A-3 3AUA0000108028 is a 110 kW, 206 A, 400 V ACS880-01 IP21 wall-mounted industrial drive in frame R7.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS880-01-206A-3 3AUA0000108028
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS880-01-206A-3 3AUA0000108028

  • Manufacturer:
    ABB
  • Part Number:
    ACS880-01-206A-3 3AUA0000108028
  • Product Family:
    ABB Drives
  • Product Type:
    ACS880 Industrial Wall-Mounted Single Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000108028
  • Nominal Motor Power:
    110 kW
  • Normal Output Current:
    206 A
  • Light-Duty Rating:
    196 A / 110 kW
  • Heavy-Duty Rating:
    169 A / 90 kW
  • Maximum Output Current:
    287 A
  • Frame Size:
    R7
  • Input:
    3-phase, 380–415 V AC
  • Input Frequency:
    47.5–63 Hz
  • Protection:
    IP21 / NEMA Type 1
  • Mounting:
    Wall-mounted
  • Control I/O:
    2 AI, 2 AO, 6 DI, 2 DO
  • Apparent Power Output:
    143 kVA
  • Power Consumption:
    2816 W
  • Sound Pressure:
    67 dB(A)
  • Maximum Temperature Rating:
    40 °C
  • Weight:
    53 kg
  • Estimated shipping dimensions:
    99.2x59.8x40cm
  • Tariff Code:
    85044087
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Project Planning Motor & Braking Commissioning

Features:

  • 110 kW and 206 A normal-use rating at 400 V
  • R7 wall-mounted enclosure with IP21 protection
  • Direct Torque Control with built-in Safe Torque Off
ACS880-01-206A-3 3AUA0000108028 is the 110 kW, 206 A normal-use configuration in ABB’s ACS880-01 industrial drive range.

ACS880-01-206A-3 3AUA0000108028 uses the R7 mechanical format and provides the documented current ratings needed to evaluate normal, light-overload, and heavy-duty motor applications.

ACS880-01-206A-3 3AUA0000108028 should be ordered after the motor schedule, duty cycle, supply and earthing, protection, cabling, cooling, braking, safety circuit, and option scope have been approved.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS880-01-206A-3 3AUA0000108028 ACS880 Industrial Wall-Mounted Single Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS880-01-206A-3 3AUA0000108028 ACS880 Industrial Wall-Mounted Single Drive Specs

General

  • ManufacturerABB
  • ModelACS880-01-206A-3 3AUA0000108028
  • ConditionNew Original ready stock
  • Product FamilyABB ACS880-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

R7 delivery and installation scope

  • Handling: Approve the delivery route, lifting method, mounting support, and final orientation for the R7 drive.
  • Electrical design: Coordinate the 206 A normal-use rating with the site fault-current, isolation, protection, and conductor studies.
  • Thermal plan: Provide the documented airflow and keep control, fan, power-terminal, and option-module access clear.
  • Responsibilities: Assign ownership for signals, networks, safety validation, commissioning, records, and maintenance.

110 kW duty review

  • Motor match: Compare nameplate current and load torque with the 206 A normal-use and 169 A heavy-duty points.
  • Acceleration: Calculate starting torque, inertia, ramp time, peak current, and process limits before startup.
  • Braking: Calculate regenerative energy, stopping time, repetition, chopper scope, resistor duty, and thermal protection.
  • Cabling: Verify motor insulation, cable construction, length, routing, shield termination, and bearing-current measures where required.

R7 acceptance controls

  • Pre-power checks: Verify identifiers, options, mounting, PE continuity, insulation, terminations, airflow, and Safe Torque Off wiring.
  • Motor data: Enter the complete motor nameplate values and follow the approved identification procedure.
  • Functional test: Prove direction, commands, references, interlocks, network loss behavior, limits, and loaded response.
  • Handover: Archive firmware, option codes, parameters, test results, fault baseline, drawings, and the recovery procedure.
Description
ACS880-01-206A-3 3AUA0000108028 provides the 110 kW, 206 A normal-use rating at the upper R7 level of ABB’s ACS880-01 wall-mounted drive range for 380–415 V three-phase installations with IP21 protection.

ACS880-01-206A-3 3AUA0000108028 uses Direct Torque Control and the ACS880 control platform to coordinate a high-current motor with process references, analog and digital signals, safety stop functions, fault reporting, and the project’s selected network interfaces.

ACS880-01-206A-3 3AUA0000108028 demands confirmation of the 196 A light-duty and 169 A heavy-duty points, transport and lifting, R7 support, fault-current and isolation studies, large-conductor routing, enclosure heat removal, braking energy, motor insulation, safety testing, commissioning, and maintenance readiness.
Alternative Names
ACS880 01 206A 3 ACS88001206A3 3AUA0000108028 ABB ACS880-01-206A-3 ABB ACS880-01-206A-3 3AUA0000108028 ACS880 110 kW R7 wall mounted drive ACS880-01-206A-3 206 A industrial drive
Technical notes
Release ACS880-01-206A-3 3AUA0000108028 only after the 110 kW motor duty has been checked against the 206 A normal-use and 169 A heavy-duty ratings. Complete the R7 logistics, 380–415 V feeder and protection study, high-current cable and earthing design, airflow, braking analysis, Safe Torque Off validation, communication scope, loaded acceptance test, and recovery plan.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why must a 110 kW selection be checked against the 169 A heavy-duty point before approving ACS880-01-206A-3 3AUA0000108028?
The 206 A normal-use label does not define a high-overload application. Compare motor current, torque profile, acceleration, overload magnitude and duration, repetition, and recovery with the 169 A and 90 kW heavy-duty basis.
How should the 2816 W documented loss of ACS880-01-206A-3 3AUA0000108028 influence ventilation and equipment spacing?
Use it in the complete room or enclosure heat balance with site ambient, adjacent losses, airflow capacity, recirculation, and ABB derating instructions. Preserve the approved R7 cooling path, terminal access, and maintenance clearances.
A loaded start drives ACS880-01-206A-3 3AUA0000108028 toward 287 A; what proves whether the event is acceptable?
Correlate current, speed, torque demand, motor data, ramp, inertia, mechanical condition, supply quality, duration, repetition, and fault records. Acceptance depends on the approved duty profile, not on the maximum-output figure alone.
Which engineering differences prevent a lower-current R7 drive from being substituted directly by ACS880-01-206A-3 3AUA0000108028?
Recheck the 206 A rating, protection, conductors, terminals, heat rejection, motor and braking duty, control I/O, options, firmware, parameters, safety wiring, mounting support, and drawings before any replacement decision.
For repetitive deceleration at the 110 kW level, what braking study is required around ACS880-01-206A-3 3AUA0000108028?
Calculate regenerated energy, peak braking power, stopping time, repetition rate, motor speed range, and thermal duty. Confirm the approved chopper, resistor, protection, and safe stopping configuration from ABB documentation.
Which acceptance and recovery records should be specified when purchasing ACS880-01-206A-3 3AUA0000108028?
Request the complete Product ID and option record, motor and duty basis, protection and cable design, final parameters, firmware, safety and loaded test results, drawings, backup, fault baseline, quantity, destination, and recovery procedure.