Technical specifications for MFDT-01 68566380

  • Manufacturer:
    ABB
  • Part Number:
    MFDT-01 68566380
  • Product Family:
    ABB Drives
  • Product Type:
    Drive Programming Tool
  • Stock:
    1
  • Tool Family:
    FlashDrop
  • MRP Code:
    68566380
  • Typical Use Time:
    Approximately 4 hours
  • Charge Time:
    Approximately 1.5 hours
  • Operating Temperature:
    -10 to +40 °C
  • PC Connection:
    OPCA-02 data cable
  • Tool Weight:
    Approximately 0.4 kg
  • Standard:
    IEC/EN 61800-3:2004
  • Weight:
    2.87 lbs (1.3 kg)
  • Estimated shipping dimensions:
    5 x 15.5 x 7 cm
  • Tariff Code:
    8537109090
  • Country of origin:
    Finland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Compatibility Parameter Workflow Operation Applications

Features:

  • Portable storage and transfer of compatible drive parameter sets.
  • Handheld control panel with PC-based DrivePM support.
  • Rechargeable operation for commissioning and maintenance work.
MFDT-01 68566380 brings parameter upload, editing, storage, and download functions into a portable service tool.

The programming tip connects to the supported FlashDrop interface so parameter work can be prepared without normal drive operation.

DrivePM manages templates and stored sets on a PC before they are transferred to the handheld unit.

The ABB MFDT-01 68566380 Drive Programming Tool may remain available for purchase and support from Apter Power beyond manufacturer end-of-life.
ABB MFDT-01 68566380 Drive Programming Tool Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

MFDT-01 68566380 drive compatibility

  • Drive family: FlashDrop use is supported for applicable ABB ACS150, ACS350, ACS550, and ACH550 drives.
  • Template match: The available template must match drive type, control mode, parameter-table version, and localization.
  • Rating check: Download protection compares the stored set with the connected drive rating before transfer.
  • Interface requirement: The target drive must provide the supported FlashDrop connection used by the MFDT-01 programming tip.

MFDT-01 68566380 parameter workflow

  • Upload: A complete compatible parameter set can be read from a connected drive into the handheld tool.
  • Edit and store: Selected values can be reviewed and saved in named sets for later reuse.
  • Download: A checked set can be transferred to another compatible drive after identity and rating validation.
  • Parameter visibility: DrivePM can prepare parameter groups so field users see only the values intended for the service task.

MFDT-01 68566380 service operation

  • Battery use: Typical operating time is approximately four hours, with about 1.5 hours required for charging.
  • PC link: The OPCA-02 cable connects the base unit to DrivePM for template and set management.
  • Fault review: Displayed errors distinguish missing drives, incompatible sets, absent templates, and file-system problems.
  • Portable controls: The removable panel and programming tip let the operator select files, review checks, and confirm transfers at the drive.

Supported projects for MFDT-01 68566380

  • Series commissioning: MFDT-01 68566380 can copy an approved parameter set across multiple compatible drives in machine production.
  • Replacement drives: MFDT-01 68566380 can restore a compatible saved set after a failed drive is exchanged.
  • Workshop preparation: MFDT-01 68566380 can organize and verify parameter sets before technicians reach the installed equipment.
  • Spare-drive staging: MFDT-01 68566380 can load an approved setup into a compatible spare through FlashDrop without energizing the main power circuit.
Description
ABB MFDT-01 68566380 is a FlashDrop drive programming tool supplied as a handheld base unit, removable control panel, programming tip, charger, PC cable, and DrivePM software workflow. The package is intended for portable commissioning and service of supported low-voltage drives.

MFDT-01 68566380 can read, edit, store, and transfer compatible parameter sets through the FlashDrop connection without energizing the drive main circuit. A verified setup can therefore be prepared or restored while the target drive remains isolated from normal operation.

DrivePM organizes templates and saved sets before they are loaded into MFDT-01 68566380. Compatibility checks compare drive type, rating, control mode, parameter-table version, and localization so an unsuitable set is blocked before download.

The rechargeable MFDT-01 68566380 supports approximately four hours of typical portable use and about 1.5 hours of charging. Its display reports missing drives, unavailable templates, incompatible sets, and file-system conditions to guide the operator through the transfer sequence.
Alternative Names
68566380 MFDT-01 ABB MFDT-01 68566380 MFDT 01 68566380 MFDT01 68566380 MFDT-O1 68566380 MFDT-01 6856638O ABB FlashDrop MFDT-01 Flash Drop MFDT-01 68566380
Technical notes
MFDT-01 68566380 depends on matching DrivePM templates and drive metadata; an incompatible type, rating, control mode, parameter table, or localization blocks transfer.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should a parameter set be checked before MFDT-01 68566380 downloads it?
MFDT-01 68566380 should compare the drive type, rating, control mode, parameter-table version, and localization so an incompatible set is not written to the connected drive.
Can MFDT-01 68566380 program a supported drive without mains power?
MFDT-01 68566380 is designed to use the supported FlashDrop connection for parameter transfer without energizing the drive's main power circuit; follow the drive-specific safety procedure.
How are missing drive templates added to MFDT-01 68566380?
Use DrivePM and the OPCA-02 PC cable to load the applicable ABB template package into MFDT-01 68566380, then confirm the template properties before creating or transferring a set.
What should be backed up before replacing MFDT-01 68566380?
Before replacing MFDT-01 68566380, export or document stored parameter sets, template versions, DrivePM files, cable details, and the compatible drive list used by the maintenance team.
How long can MFDT-01 68566380 typically operate between charges?
MFDT-01 68566380 provides approximately four hours of typical use and requires about 1.5 hours to recharge under the conditions stated in the user manual.
What causes an incompatible-set error on MFDT-01 68566380?
MFDT-01 68566380 reports compatibility problems when the stored set differs from the target drive type, rating, control mode, parameter-table version, localization, or available template.
Which drives are documented for use with MFDT-01 68566380?
MFDT-01 68566380 documentation identifies FlashDrop support for applicable ABB drive families including ACS150, ACS350, ACS550, and ACH550; verify the exact drive and template revision.