Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports exact-model review, documentation checks and sourcing coordination for this active ABB product.

FET3211S0A1A2C0H2M6/3K672013030195

/ 4.9
1001 reviews | Need a Specific Revision?
ABB FET3211S0A1A2C0H2M6/3K672013030195 is a ProcessMaster remote transmitter configured for 24 VAC/DC supply, HART communication and IP67 enclosure protection.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for FET3211S0A1A2C0H2M6/3K672013030195
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FET3211S0A1A2C0H2M6/3K672013030195

  • Manufacturer:
    ABB
  • Part Number:
    FET3211S0A1A2C0H2M6/3K672013030195
  • Product Family:
    ABB Electrical Industries
  • Product Type:
    ProcessMaster Remote Transmitter
  • Stock:
    1
  • Product family:
    ProcessMaster
  • Transmitter arrangement:
    Remote
  • Power supply:
    24 VAC/DC, 50 Hz
  • Communication:
    HART
  • Enclosure protection:
    IP67
  • Software version:
    D200S069U01
  • Firmware revision:
    01.02.00
  • Weight:
    3.3 kg
  • Estimated shipping dimensions:
    21 x 30 x 14 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    China
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Meter Configuration Power and HART Enclosure and Setup Product Applications

Features:

  • Remote ProcessMaster electronics: separates transmitter access from the installed flow sensor
  • HART interface: supports the communication configuration marked on the supplied ABB unit
  • IP67 housing: protects the remote enclosure while sensor configuration remains installation-specific
The complete configuration string distinguishes this transmitter from other FET321 order variants.

Its 24 VAC/DC and HART markings are immediate electrical and communication release points for a service spare.

The remote arrangement does not remove the need to restore the paired sensor and process setup.

For FET3211S0A1A2C0H2M6/3K672013030195 ABB ProcessMaster Remote Transmitter enquiries, Apter Power supports document review, quotation and procurement coordination.
ABB FET3211S0A1A2C0H2M6/3K672013030195 ProcessMaster Remote Transmitter Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Remote arrangement: the FET321 electronics are installed separately from the flow sensor.
  • Complete order string: the full configuration code controls the supplied transmitter variant.
  • Sensor relationship: the installed sensor identity remains part of the meter system.
  • Commissioning effect: process settings must be restored before measurement is released.
  • Supply marking: the supplied unit is labelled 24 VAC/DC, 50 Hz.
  • Power demand: the nameplate states less than 20 VA.
  • Communication: HART is the marked transmitter protocol.
  • Service boundary: supply and communication must both match the host installation.
  • Protection marking: IP67 applies to the supplied transmitter enclosure.
  • Remote location: installation position can differ from the sensor location.
  • Configuration source: the sensor and retained application record govern restoration.
  • Stop condition: do not release an unexplained sensor or flow-direction mismatch.
  • Conductive-liquid flow measurement: serve as the remote transmitter in an ABB ProcessMaster electromagnetic flowmeter.
  • Remote electronics access: place the transmitter where operating and maintenance access is practical.
  • HART plant integration: connect the documented transmitter configuration to a HART-capable host.
Description
In a remote ProcessMaster installation, FET3211S0A1A2C0H2M6/3K672013030195 places the transmitter electronics away from the flow sensor. The arrangement lets operators choose a practical location for viewing and servicing the electronics without moving the measuring point.

The supplied label makes FET3211S0A1A2C0H2M6/3K672013030195 a specific 24 VAC/DC, HART and IP67 configuration. Those markings guide the electrical, host-communication and enclosure checks that must be completed before a family-level FET321 spare can be released.

After a hardware exchange, FET3211S0A1A2C0H2M6/3K672013030195 still depends on the paired sensor identity and the retained application settings. Power-up and HART communication show that the electronics are accessible; they do not by themselves prove that the original measurement configuration has been restored.
Alternative Names
FET3211S0A1A2C0H2M6 3K672013030195 FET3211S0A1A2C0H2M6 3K672013030195 FET321
Technical notes
ABB identifies FET3211S0A1A2C0H2M6/3K672013030195 as a remote ProcessMaster transmitter with HART, 24 VAC/DC supply and IP67 protection. Those attributes do not restore the paired sensor data automatically. Site commissioning must stop until the sensor identity, flow direction and application parameters agree with the installed meter record.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
A remote ProcessMaster transmitter has failed; can maintenance order FET3211S0A1A2C0H2M6/3K672013030195 from the FET321 family name alone?
No. Release the spare only when the complete configuration string, 24 VAC/DC supply and HART interface match the installed transmitter record.
The replacement powers up but the indicated flow is not credible; what should be checked first on FET3211S0A1A2C0H2M6/3K672013030195?
Start with the paired sensor identity, flow direction and retained application parameters. Power-up confirms the electronics are energized; it does not prove that the meter configuration matches the installed sensor.
Can FET3211S0A1A2C0H2M6/3K672013030195 be connected to a supply selected only from another FET321 installation?
No. Use the 24 VAC/DC marking on this exact unit and compare the installed protective and wiring arrangement before energization.
A control-system engineer needs HART access after replacing FET3211S0A1A2C0H2M6/3K672013030195; what must remain unchanged?
Keep the documented HART loop arrangement and host settings, then confirm communication before altering process parameters. The transmitter label establishes HART capability but not the site loop design.
Is the IP67 marking enough to install FET3211S0A1A2C0H2M6/3K672013030195 in any outdoor location?
No. IP67 addresses enclosure ingress protection; cable entries, ambient conditions and any hazardous-area requirement still belong to the complete installation assessment.
What should receiving compare before accepting FET3211S0A1A2C0H2M6/3K672013030195?
Compare the complete configuration code, ABB article number, 24 VAC/DC supply, HART marking and IP67 enclosure label with the purchase order. Hold the unit if any controlled identifier differs.