Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power coordinates verified condition, documentation, quotation, and delivery planning for dependable safety-controller procurement.

5069-L320ERS2

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 5069-L320ERS2 is a Compact GuardLogix 5380 SIL 2 controller with separate standard and safety memory for distributed machine control.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 5069-L320ERS2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 5069-L320ERS2

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    5069-L320ERS2
  • Product Family:
    CompactLogix 5069
  • Product Type:
    Compact GuardLogix 5380 SIL 2 Controller
  • Stock:
    1
  • Standard user memory:
    2 MB
  • Safety user memory:
    1 MB
  • Local Compact 5000 I/O:
    16 modules max
  • EtherNet/IP nodes:
    40 max with Logix Designer v31 or later
  • Controller tasks:
    31 standard tasks and 1 safety task
  • Embedded ports:
    2 Ethernet ports and 1 USB 2.0 Type B port
  • Ethernet modes:
    Dual-IP or Linear/DLR
  • MOD power:
    18...32 V DC SELV/PELV
  • Power dissipation:
    9 W max
  • Mounting:
    Horizontal DIN rail
  • Operating temperature:
    0...60 °C
  • Relative humidity:
    5...95% noncondensing
  • Weight:
    0.768 kg
  • Estimated shipping dimensions:
    14.397 x 9.81 x 13.681 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Multiple
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Safety Setup Network Modes Local I/O Product Applications

Features:

  • Unified safety control: standard execution and one SIL 2 safety task in the same controller
  • Separate memory pools: 2 MB for standard logic and 1 MB for safety logic
  • Embedded EtherNet/IP: two ports for Dual-IP or Linear/DLR architectures
5069-L320ERS2 gives a machine builder one Compact 5000 control point for ordinary sequencing and safety functions.

Its engineering value is the controlled relationship between the safety task, local I/O ownership, and the selected Ethernet topology.

The nameplate, Series, firmware, project checksum, and validation record should travel together when the controller is stocked or replaced.

Apter Power can coordinate official-document review, quotation, and sourcing support for 5069-L320ERS2.
Allen-Bradley 5069-L320ERS2 Compact GuardLogix 5380 SIL 2 Controller Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Safety Commissioning Controls

  • Controller definition: match the installed Series and firmware before restoring the project.
  • Safety signature: recover the approved signature only from the controlled project archive.
  • Output release: complete the documented proof test before enabling the machine.

EtherNet/IP Architecture Choices

  • Dual-IP: assign each embedded port to a separately addressed network when the design requires segmentation.
  • Linear/DLR: use one controller address across the port pair for a line or device-level ring.
  • Connection paths: rebuild and test device paths whenever the selected mode changes.

Compact 5000 Local I/O Planning

  • Local bank: keep the installed sequence within the documented sixteen-module boundary.
  • Power entry: provide the MOD and SA connections through the selected 5069 RTB kit.
  • Acceptance: verify ownership, status, and safety responses for every local module.

Product Applications

  • Safety machine cells: coordinate standard sequencing with a SIL 2 safety task.
  • Local safe I/O: control Compact 5000 safety and standard modules in one bank.
  • Segmented equipment: separate machine and plant networks through an approved Dual-IP design.
Description
5069-L320ERS2 is a Compact GuardLogix 5380 controller that combines standard machine control with one SIL 2 safety task. Rockwell Automation assigns 2 MB to the standard application and 1 MB to safety logic, so the two memory pools must be managed separately.

Inside a Compact 5000 architecture, 5069-L320ERS2 can coordinate local standard and safety I/O while its two embedded EtherNet/IP ports support either separately addressed Dual-IP networks or one Linear/DLR network. This lets the controller serve a machine cell without adding a separate chassis communication module.

A 5069-L320ERS2 project should be approved against the installed controller Series, supported Studio 5000 firmware definition, safety signature, and validated network design. Any replacement or controlled logic change requires the documented safety acceptance procedure rather than a normal standard-controller download alone.
Revisions

Revision Part #

Also known as

5069-L320ERS2 Series A
5069-L320ERS2/A, Series A
5069-L320ERS2 Series B
5069-L320ERS2/B, Series B
Alternative Names
Allen-Bradley 5069-L320ERS2 Rockwell Automation 5069-L320ERS2 AB 5069-L320ERS2 5069L320ERS2 5069 L320ERS2 Compact GuardLogix 5380 two-megabyte SIL 2 controller
Technical notes
Restoring 5069-L320ERS2 from an archive with a different controller Series or firmware can prevent the approved safety signature from matching. Confirm the controller definition before download, recover the authorized signature, and complete the documented proof test before enabling safety outputs; treat topology changes as controlled safety modifications.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can 5069-L320ERS2 accept standard logic while the safety task remains locked?
Check the controller definition, firmware, safety ownership, signature state, and whether the archived project was created for the installed Series before attempting another download.
What should be investigated when 5069-L320ERS2 devices disappear after an Ethernet-mode change?
Compare the new port addresses with controller paths, remote-I/O ownership, produced and consumed connections, switch settings, and routing; then test reconnection on both network sides.
How should a maintenance team prepare a commissioned 5069-L320ERS2 spare?
Store the verified firmware package, controlled project, safety signature record, network settings, I/O inventory, nameplate images, and an approved replacement-and-proof-test procedure.
When does 5069-L320ERS2 expansion require a remote adapter instead of another local module?
Review the installed local-bank count, physical rail sequence, MOD and SA power, and the official sixteen-module boundary before assigning additional I/O to the local assembly.
Which change-control evidence is needed after modifying 5069-L320ERS2 safety logic?
Retain the change authorization, compiled project, new signature, affected safety-function tests, fault-response results, approval record, and rollback copy required by the site procedure.
How can procurement avoid receiving the wrong 5069-L320ERS2 controller variant?
Require clear front and side nameplates, the complete catalog number, Series and firmware, then compare the requested safety level and motion requirement with the official catalog entry.

Product Browsing History