Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power reviews controller identity, firmware records, condition, official documentation, quotation, and sourcing requirements.

5069-L306ER

/ 4.9
1001 reviews | Need a Specific Revision?
For smaller Compact 5000 architectures, Allen-Bradley 5069-L306ER provides Logix control with selectable Dual-IP or embedded-switch Ethernet operation and a focused local I/O footprint.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 5069-L306ER
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 5069-L306ER

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    5069-L306ER
  • Product Family:
    CompactLogix 5069
  • Product Type:
    CompactLogix 5380 600 KB EtherNet/IP Controller
  • Stock:
    1
  • User memory:
    600 KB
  • Maximum local I/O modules:
    8
  • Maximum EtherNet/IP nodes:
    16
  • Ethernet ports:
    2 x 1 Gb
  • Supported Ethernet modes:
    Dual-IP, linear, or DLR
  • Programming port:
    USB 2.0 Type-B
  • MOD power input:
    18...32 V DC
  • MOD power consumption:
    8.5 W maximum
  • Operating temperature:
    0...60 °C
  • Enclosure type:
    Open-style
  • Removable terminal blocks:
    MOD power and SA power
  • Weight:
    1.693 lbs (0.768 kg)
  • Estimated shipping dimensions:
    14.397x9.81x13.681cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Multiple
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Power Domains Local I/O Bank Node Allocation Product Applications

Features:

  • Right-sized controller tier: 600 KB establishes the exact project-capacity boundary for this catalog
  • Selectable network role: the two gigabit ports support either separate IP interfaces or switched topology
  • Compact 5000 platform: local I/O and controller power are designed as one adjacent bank
5069-L306ER is the smaller of the two CompactLogix 5380 controllers in this review and should be chosen from a measured project rather than enclosure appearance.

Its network mode changes how the two physical connectors behave, so the intended architecture must be visible in the design record.

The local Compact 5000 I/O bank also introduces separate controller-side and field-side power considerations that are not represented by the memory figure.

Apter Power can assist with official-document verification, quotation, and procurement coordination for 5069-L306ER.
Allen-Bradley 5069-L306ER CompactLogix 5380 600 KB EtherNet/IP Controller Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • MOD supply: power the controller and local communication circuitry within the published DC input range.
  • SA supply: match sensor and actuator power to the installed Compact 5000 I/O requirements.
  • Current calculation: include every local module and field load in the appropriate power-domain budget.
  • RTB integrity: verify terminal-block keying, polarity, conductor preparation, and full seating.
  • Catalog sequence: keep each Compact 5000 I/O catalog and slot position aligned with the project.
  • Software boundary: apply the local-module limits documented for the controller and Logix Designer version.
  • Electronic keying: use the approved module identity and revision policy rather than bypassing a mismatch.
  • Fault isolation: use controller and module diagnostics to separate profile, power, and field-side faults.
  • Official definition: count devices according to the EtherNet/IP node rules for the supported software version.
  • Connection demand: assess I/O, produced data, messages, drives, and supervisory clients separately.
  • Traffic behavior: validate requested packet intervals and multicast handling under peak machine operation.
  • Growth reserve: document capacity for approved additions instead of consuming the full design margin.
  • Standalone control systems: run a verified Logix application with local Compact 5000 I/O.
  • Networked automation systems: coordinate supported EtherNet/IP devices within the published node scope.
  • Separated network designs: use Dual-IP mode where two independently addressed networks are required.
  • Linear or DLR systems: use the embedded switch for the documented chained or resilient topology.
Description
5069-L306ER is the 600 KB member of the CompactLogix 5380 controller family, intended for Logix control systems that remain within its published local-I/O and EtherNet/IP node boundaries. The controller uses Compact 5000 I/O directly beside the processor.

Two 1 Gb Ethernet interfaces allow 5069-L306ER to operate in Dual-IP mode or as an embedded switch in linear and Device Level Ring layouts. This gives the same hardware two clearly different network roles without implying that both behaviors operate simultaneously.

A well-scoped 5069-L306ER project balances program size, connected architecture, and the controller-bank power design. It is most useful when those limits fit the machine without paying for a higher controller tier that the verified application does not require.
Revisions

Revision Part #

Also known as

5069-L306ER Series A
5069-L306ER/A, Series A
5069-L306ER Series B
5069-L306ER/B, Series B
Alternative Names
Allen-Bradley 5069-L306ER controller Rockwell Automation 5069-L306ER AB 5069 L306ER 5069L306ER CompactLogix 5380 CompactLogix 5380 600 KB controller 5069-L306ER 5069-L306ER Dual-IP PLC
Technical notes
The two Ethernet connectors on 5069-L306ER do not always represent two independent controller networks. Select Dual-IP only when separate addressed subnets are required; otherwise document the linear or DLR switch topology, controller address, and recovery behavior during controlled commissioning and record the results before replacing the processor.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why can local I/O beside 5069-L306ER remain offline even when controller power is present?
MOD power can be healthy while SA power, RTB seating, electronic keying, module firmware, or field wiring prevents the bank from starting. Follow the controller diagnostics before replacing modules.
What should an integrator do when 5069-L306ER is reachable through one network but not the other?
First identify whether the controller is configured for Dual-IP or switch mode, then compare port status, IP assignments, gateways, cabling, and managed-switch settings with that intended mode.
How should project memory be judged before selecting 5069-L306ER?
Use the compiled Logix Designer memory report, include online-edit and maintenance margin, and stop the selection if the verified application cannot remain inside the 600 KB capacity.
When can a new Ethernet device cause a 5069-L306ER project to exceed its design?
A device can add node, connection, packet-rate, or message demand. Recalculate each resource and test peak network behavior before adding it to production.
What should be stored with 5069-L306ER before a planned outage?
Keep the approved project, firmware and software versions, network-mode diagram, IP assignments, module profiles, power calculations, and a controlled download and communication test.
What should incoming inspection verify on a sourced 5069-L306ER?
Match the full catalog and series, inspect both Ethernet ports, USB and power RTBs, review traceability and physical condition, then bench-load the approved firmware and project.