Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports evidence-based controller sourcing, condition review, quotation, documentation, and coordinated delivery for industrial upgrades.

5069-L330ER

/ 4.9
1001 reviews | Need a Specific Revision?
With 3 MB of application memory, Allen-Bradley 5069-L330ER extends a Compact 5000 panel to thirty-one local modules while managing a sixty-node Ethernet project.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for 5069-L330ER
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 5069-L330ER

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    5069-L330ER
  • Product Family:
    CompactLogix 5069
  • Product Type:
    CompactLogix 5380 Controller
  • Stock:
    1
  • User memory:
    3 MB
  • Local Compact 5000 I/O:
    31 modules max
  • EtherNet/IP nodes:
    60 max with Logix Designer v31 or later
  • Controller tasks:
    32
  • Programs per task:
    1000
  • Embedded ports:
    2 Ethernet ports and 1 USB 2.0 Type B port
  • Ethernet modes:
    Dual-IP or Linear/DLR
  • MOD power:
    18...32 V DC SELV/PELV
  • Power dissipation:
    8.5 W max
  • Mounting:
    Horizontal DIN rail
  • Operating temperature:
    0...60 °C
  • Relative humidity:
    5...95% noncondensing
  • Weight:
    1.693 lbs (0.768 kg)
  • Estimated shipping dimensions:
    14.397 x 9.81 x 13.681 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Singapore
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals I/O Layout Traffic Load Service Access Product Applications

Features:

  • Broader local control: 3 MB user memory with an extended Compact 5000 bank
  • DIN-rail architecture: embedded programming and Ethernet interfaces
  • Expansion focus: local layout, power, and traffic planned as one system
5069-L330ER is positioned for projects whose local I/O footprint has grown beyond the sixteen-module class.

Its selection value is the combination of a thirty-one-module bank and greater network scope, not memory alone.

Acceptance records should preserve the exact module order, power groups, topology, connection census, and online performance results.

Apter Power can coordinate official-document review, quotation, and sourcing support for 5069-L330ER.
Allen-Bradley 5069-L330ER CompactLogix 5380 Controller Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Thirty-One-Module Expansion Layout

  • Physical sequence: document every module position, width, terminal set, and removal clearance.
  • Power groups: calculate MOD and SA distribution across the complete local assembly.
  • Serviceability: verify rail support, labels, ventilation, and access before cabinet release.

EtherNet/IP Traffic Budget

  • Node census: reconcile the complete I/O tree with the documented software-version condition.
  • Connection load: include cyclic I/O, HMIs, messaging, diagnostics, and programming access.
  • Growth reserve: assign capacity only to approved future devices and test the expected load.

Network Maintenance Access

  • Address record: preserve port mode, IP settings, switch ports, and routing information.
  • Diagnostic route: confirm authorized engineering access without disrupting machine I/O.
  • Recovery test: prove reconnection after the network fault anticipated by the topology.

Product Applications

  • Expanded machine lines: control a larger local Compact 5000 I/O sequence.
  • Distributed production cells: coordinate remote adapters, drives, and operator interfaces.
  • Maintained networks: separate operating and engineering access through an approved topology.
Description
5069-L330ER is a 3 MB CompactLogix 5380 controller intended for applications that need a larger local Compact 5000 I/O footprint. Its embedded USB and two-port EtherNet/IP interfaces are integrated into the DIN-rail controller.

A 5069-L330ER system can extend the local bank to the documented thirty-one-module level while using Dual-IP or Linear/DLR networking for distributed devices. This makes enclosure layout, power grouping, and traffic design as important as the compiled project size.

Engineering approval for 5069-L330ER should include the exact local sequence, final Ethernet census, software version, task loading, MOD and SA power, RTB style, and maintenance clearance. Validate the completed architecture under representative communications rather than at an empty-panel stage.
Revisions

Revision Part #

Also known as

5069-L330ER Series A
5069-L330ER/A, Series A
Alternative Names
Allen-Bradley 5069-L330ER Rockwell Automation 5069-L330ER AB 5069-L330ER 5069L330ER 5069 L330ER CompactLogix 5380 three-megabyte controller
Technical notes
A 5069-L330ER project can remain within its memory allocation and still overload the planned network. Build the final node and connection census, include HMI and messaging traffic, reserve only approved expansion capacity, and verify reconnection under representative load before treating the sixty-node catalog boundary as usable system headroom.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should phased expansion be reserved in a 5069-L330ER project?
Document only approved future modules and devices, then reserve rail space, MOD and SA power, terminals, network connections, addresses, and tested performance margin for that scope.
Why can 5069-L330ER communications become slow even below the catalog node count?
Requested packet intervals, produced and consumed data, messages, HMI polling, diagnostics, and switch behavior can consume bandwidth and controller resources before the numerical ceiling is reached.
What should be reviewed when a long 5069-L330ER local bank is difficult to service?
Check module spacing, terminal access, wire routing, rail support, ventilation, labeling, removal sequence, and whether the enclosure allows a module to be replaced safely.
How can a network technician reach 5069-L330ER without crossing the machine I/O segment?
Use the approved Dual-IP and routing design, authorized switch path, and security controls; verify that engineering access is deliberately assigned rather than bridged informally.
Why might an added remote adapter destabilize 5069-L330ER after commissioning?
The change can alter the node and connection census, update traffic, switch loading, power design, and recovery behavior; repeat the relevant performance and fault tests.
Which records make a 5069-L330ER quotation technically reviewable?
Include nameplate and Series, firmware, project size, local module list, connection census, network mode, RTB preference, condition, quantity, destination, and required date.